Skip to Content
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Trusted Since 1999 Trusted Since 1999
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google

Customer Questions and Answers for Dryer Electronic Control Board - No Housing by Frigidaire

Best Seller
Manufacturer Part
4.89 (64)
By: Frigidaire
Part Number: OEM20670792
Manufacturer Part Number: 134557200NH

This is the main electronic control board for the dryer, sold without the outer housing. It manages dryer functions including cycle selection, temperature regulation, and timing. Replace this board if the dryer won't start, stops mid-cycle, displays error codes, or if the controls are unresponsive - note that the existing housing from your old board will need to be reused.

More

Questions & Answers

For Frigidaire Dryer Electronic Control Board - No Housing (Part Number: OEM20670792)

1 Answer

Hello Mack, you should be able to see the model/serial tag on the side of drum opening panel/frame once the door is opened, you can also try looking on the outer rear cabinet panel near the top.

Read More...

1 Answer

Hello Mark,at this point likely the heater element relay on the control board is stuck closed, check this by just running a no heat cycle if the dryer is still heating, then the control board will need to be replaced,DC92-01626A.

Read More...

1 Answer

Dominic,

Try to shut off the power to the oven for 5 minutes and then turn it back on. There may be a problem with the unit in which a control or touchpad may be the issue but normally will get an error code.

Read More...

1 Answer

The first thing I would do Rich is to verify that it was the correct part for my model. If is it correct then double-check the wiring was correct to the instructions. If that was all good I would start checking the wiring coming into the board looking for shorts or incorrect power being applied. If you write us back and provide a model number we may be able to provide more accurate and specific help.

Read More...

1 Answer

Charles,

To remove the front panel, you will need to first remove the main top of the unit. You will do this by pulling the unit out and there will be 2 or 3 screws on the back holding the maintop. Remove the screws and slide the maintop back and lift off. Once removed there will be screws on the backside and top of the control panel that you will remove to take the control panel loose.

Read More...

1 Answer

Hello Ken, unfortunately the board in question is not compatible with the model number supplied. The correct control board for the model number supplied is part number WPW10317640. Thanks!

Read More...

1 Answer

Hello Joe,
if the control panel temp selector is stuck on low heat setting then its the control panel/control board 134557200NH, if however, you can select high heat and the dryer does not seem to get hot enough, then start by checking the exhaust vent is not restricted. Next check if the dryer has the correct incoming voltage, use a multimeter and check for 240v at the rear terminals. If ok, you will need to check the heater element for any problems like a short or ground.It should ohm at about 12 ohms. Nec

Read More...
George for Model Number AEQB7000EGO

I have a AEQB7000EGO dryer that will not heat. Everything else works without a problem. I have taken apart and tested resistance on heating element, thermostat, thermal fuse and high limit thermostat and all came out good. I ran diagnostic and get e68 error. I tried some recommendations to check for stuck buttons on board but the heating element will still not turn on. What’s interesting is I have been dealing with heating element turning in and not turning on for months. Very random. Now will not turn on at all. Is recommendation a control board at this point?

1 Answer

George,
As far as the heater goes make sure the relay in the control marked RL2 is closed and you get a reading of 120 vac on both wires when the unit is running and trying to heat. Voltage in and not out then replace the main control. If all tests good then it would be an issue with the centrifugal switch in the motor and would need to be replaced. [motor] Follow the instructions on the tech sheet for the error code.

Read More...

1 Answer

Barbara,
We will need your model number to help you find the right parts for your unit. Please post another question with all your info included thank you.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google