Irama February 27, 2017 for Model Number GI5FSAXVY02 My refrigerator sentir Bank, I replaced the Main Control Board, it Was ok for 4 days, and went of again. Only the interior lights work. What is the problem , pelease.
1 Answer Irama, With the dispenser assembly not working you will want to check the wiring harness at the top of the door to make sure that the wiring is not damaged. If this checks ok then it would be a faulty main board that is causing this issue. Read More...
Irama February 26, 2017 for Model Number GI5FSAXVY02 The a control panel of my refrigerator after blinking and With a noise went Black, the interior lights working. I replaced the Control Board and after 4 days working ok, the problem is Back. What is going on With it?
1 Answer Irama, You will want to make sure that the wiring harness is not damaged at the top of the door and no loose connections. If this checks ok then the issue will most likely be a faulty main control board which is part number WPW10310240. Read More...
J&J February 04, 2017 for Model Number kfis25xvwh1 The kitchen aid bottom mount refrig has blank blue screen light up with no display numbers when I push in the dispenser lever in the front as to get some water or ice and the compressor and fans will not run. The interior lights are on. When I push any of the key pads in the bottom, all the key pads light will come on and disappear when I release the pad. Also one of the central key pad seem stiff or uncompressible. Could a stuck key pad cause all the problem? Also the 4 key pads on the right and left side the screen (upper right and lower right keypad and left upper and left lower key pad) are blank and will not light up when pressed. Could the interface or display board be bad or the main HV control board be bad? How do I differentiate them with a volt meter? I don't have a schematic for kfis25xvwh1 but I used another kfis25xv schematic with a different ending other than the wh1. If I get 120 v AC at the j1 connector at pin 4 and 8 and also 12v DC at j6 connector at pin 1 and 2 on the main board, does that mean the main board is ok? If I do not get 12v DC at the display control board, Is the display board bad? I have not measured the voltage yet as the refrigerator is at the shop. I am studying the schematic at home. Thank you very much. I am looking forward to your answer. Sincerely, J&J
1 Answer J&J, Yes if there is 120 vac on the J1 pin 4 to 8 and 12 vdc on the J6 pin 1 and 2 then this would be a good HV board. The part that would be needed is the dispenser control board. Read More...
Andrew January 31, 2017 for Model Number MFI2568AES Replaced the hv board and now the ref wont program.
1 Answer Hello Andrew. It has to be done step by step and in a timely manner. If not, it will cancel out the program for the new board. Read More...
Michael January 30, 2017 for Model Number Whirlpool refrigerator GI5SVAXVL01 Will the HV control power board wpw10310240 fix my refrigerator? It would run for 3 days and then just stop working and start the process over. There was no power on the door dispenser, changed both control boards in the door and still had no luck. It will cycle on and off but will not stay on. I could press any button on the door and all the lights would come on and as soon as I let the button go the lights will go back out/dead.
1 Answer Michael, With both the display board and the main board having been replaced you will want to check the harness at the top of the door to make sure that the harness is not damaged and no broken wires. Read More...
Leonardo January 30, 2017 for Model Number RB1944SL Hello my question is how to test thermal fuse and temperature sensor to know if is good or bad. thank you
1 Answer Hello Leonardo. You test the thermal fuse for continuity. It should read closed if good. As for the temp sensor, you test it for resistance based on the temp location of where your tested it at. Example is it should read around 10k ohms at room temp 77°. You can test this with a multi-meter TJMA-DMT3. Here is a link on how to use a multi-meter. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html Read More...
Guillermo January 30, 2017 for Model Number mfi2569vem Refrigerator running all time no stop and refrigerator side is 26 'F degress My question is main board bad? or temperature control. thank you
1 Answer Hello Guillermo. You will need to check and make sure the thermistors are good. If so, then you will need to order and replace the main board on the unit. Read More...
Ivonne January 23, 2017 for Model Number GI5FSAXVY02 Hi, I am from Venezuela and unfortunately the technical service here has not determined me the failure of the refrigerator, I have a Whirpool GI5FSAXVY02, due to the power outages the refrigerator damaged, I changed the control card (Whirlpool W10162500) and now Every time the power is interrupted it goes like 3 days off until it turns on. What else can throw that flaw? Thank you
1 Answer Hello Ivonne. It sounds like due to the power outages it is damaging the boards in the unit. You need to replace the board and install a surge protector on the refrigerator. Read More...
Jason November 24, 2016 I have a whirpool gold fridge. I have replaced the HV control board and was able to input the code 1617 correctly. Everything is working now except it will not dispense ice or water, it just beeps when you press the buttons. Did I miss something or is the other control board in the front bad? It was working before the HV board went bad.
1 Answer Hello Jason. You will need to check and see if the front control panel is on child lock. If so, it will beep and not work. Read More...
Al November 11, 2016 for Model Number GI5SVAXVL01 My Whirpool Gold refrigerator Model GI5SVAXVL01 has suffered several electricity outages as a result the front panel was blank and the unit was not cooling/freezing/running at all but lights inside were functioning. I bought the 2 boards the one for the display p/n W10882878 and Electronic Control Board WPW10310240 Are these board p/n’s replaced the correct ones for my Fridge? After changing them I have a permanent code PE0 0000 (not flashing), all it does is show H20 and ICE when temp. buttons are pushed, my personality code is 1617, but cant seem to input it, I already followed all instructions to reprogram it with no luck, I just bought the p/n WPW10197428 STARTDEV and 2264017 start capacitor should I change them? Thank you for your help
1 Answer Al, Yes these 2 control boards are the correct parts for your unit and they will have to be programmed. When programming it can be somewhat of a pain if it is not done exactly correct and within a certain time to enter the programming mode. Here are the programming instructions for your unit off the tech sheet and make sure that you enter the code on the model tag. Programming Mode:NOTE: The Program Code is located on the Serial Plate on this unit after the word Code.1. Press and hold the Door Alarm Keypad.2. Press and hold Freezer Temperature DOWN /- Keypad within 3 seconds.3. Release the Door Alarm Keypad and wait 3 seconds.4. The control will display PE to indicate the programming mode.5. Entry is confirmed by pressing the Freezer Temperature DOWN /- Keypad once more.6. The control will display the current Program CODE. This value should be validated with theProgram CODE printed on the unit serial plate.NOTE: If the Program CODE is correct, the Programming Mode is exited by pressing Door Alarm Keypad for 3 seconds.7. Press the Refrigerator Temperature UP /+ Keypad or Refrigerator Temperature DOWN /- Keypad to change the digit value with each key press.8. The decimal point indicates the selected digit. Press the Freezer Temperature UP /+ Keypad to select the next digit.9. Once the desired Program CODE is entered, press and hold the Freezer Temperature DOWN /- Keypad until the Program CODE begins flashingindicating it has been saved.NOTE: If you attempt to enter an invalid Program CODE the control will not save the new code, but will beep. (The unit will NOT run with a ProgramCODE of 0000).Once the Program CODE has been saved the Programming Mode is exited by pressing any key. If the new code is incorrect thisprocess should be repeated.The Programming mode can be exited at any time by pressing Door Alarm key for 3 seconds or will exit if unattended for four minutes.Defrost Operation:The Control Board adapts the compressor run time between defrosts to achieve optimum defrost intervals by monitoring the length of time the defrostheater is on. After initial power up, defrost interval is 4 hours compressor run time. Defrost occurs immediately after the 4 hours. Read More...