For Whirlpool Control Board (Part Number: OEM11302710)

Jan for Model Number RBD276PDQ7

Ovens will not turn off when press the upper off and lower off buttons. Have to turn oven off by turning off circuit breaker. Have had the ovens for 11 years. The orange numbers for oven temp etc. have always been very dim, sometimes so dim cannot read them. The green numbers for the time are very clear and and bright. When turned breaker back on and tried oven again, the orange numbers and words were more visible than have been in years. Thought it was working better, but again the ovens would not turn off. Had to turn off breaker to get ovens to turn off. Tried again and the numbers not as bright. I'm thinking I will need a new control panel or could it be the fuse. Thank you, Jan

1 Answer

Hello Jan. Based on your description, it sounds like you may have two problems. You will need to replace the control panel 8300432 for the off button and the control board 8302967 for the display. Hope this helps.

Read More...

1 Answer

Hello Ks. You will need to test the control panel thermal fuse WP4451042 and see if it is blown. If so, you will need to replace the fuse. Hope this helps.

Read More...
Tjjn

I have a Whirlpool Accubake Double oven. Model RBD245PDQ4. One day there was a flash of a PF(power failure) code and it went away. Did not think anything of it since the oven worked fine. A couple days later the control panel went blank while the unit was heating at 350 and disabled the entire unit. The unit plugs into the breaker. I checked the breaker and it seems to be OK. I turned the breaker on and off to see if it would bring the unit life with no luck. I took a Flook pen tool to see if there was power inside the unit behind the control panel and there is power coming into the unit. I reseated many of the cables that run into the control panel and board. Still no luck.. Help!

1 Answer

Hello Tjjn. You will need to provide your model number for us to help you with this. Thanks!

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google