Harlan M October 05, 2014 for Model Number wfw9151w00 I have an error code of F3 E2 will this part fix it?
1 Answer Hello Harlan. If the water temperature sensor (NTC) value is out of range (23°F to 217°F[-5°C to 103°C]) during the water-heating step of the WASH cycle. Possible Causes/Procedure - Unplug washer or disconnect power.- Make sure that connections to water heater & CCU (TH2 & HE2 cavities)connectors are not broken or with wires detached, and that connector internalpins are visible.- Check continuity from the water heater sensor (black wires) to CCU(TH2 cavity) connector.- If the continuity diagnosis failed, the Main Harness must be replaced.- Check the resistance of heating element. - Check the resistance of the water sensor. - Plug in washer or reconnect power.- Verify the washer operation by running the Diagnostic Test cycle. - After the diagnostic test has finished, unplug washer or disconnectpower and wait for 15 seconds. Read More...