Kel May 12, 2023 for Model Number JFI2089WES10 If I replace the start device and the overload, and the compressor is still not starting, do I need a compressor?
Ann April 03, 2023 for Model Number MZF34X16DW01 i turned off to clean. tried to turn on, lights come on, LED lights blink and i set to temp and after about 30 secs, the LED lights start blinking and nothing happens. I have reset 3 times (unplugged for 2 or 3 hours and tried again)
1 Answer Ann, It would be advised to start by placing the machine into the diagnostic mode checking for error codes and doing component testing, The information for these test are located in the tech sheet packaged with your machine. {To Enter the Service Diagnostic Mode} 1. Set the freezer temperature to the lowest setting prior to entering the Service Diagnostic mode. LED1 should be the only LED illuminated. 2. Press and hold SW1 (Temp Setting) and the door switch simultaneously for 5 seconds. 3. Release both buttons after all of the LEDs are illuminated. Read More...
Marvin July 07, 2019 for Model Number WRT519SZDT02 Food and freezer compartments not cold enough--45 and 25 degrees respectively. Compressor windings measure approximately 4 and 5 ohms, 9 ohms total when measured in series. Total current draw on refrigerator when running is 0.5 amps. Start relay has minor rattle sound when shaken. Does the compressor draw that little amperage when the start relay fails? Do I need a new start relay and capacitor? The capacitor is 12 uF Part# W10590083 The relay number is W10798748 Thanks, Marvin
1 Answer Marvin, You will need a start relay. The compressor draws no current when the start device fails because it will not run. It tries to start and draws current only for a couple of seconds.W11092533 Read More...