Customer Questions and Answers for Microwave Diode by Whirlpool

Best Seller
Manufacturer Part
4.89 (64)
By: Whirlpool
Part Number: OEM20352870
Manufacturer Part Number: W11256462

Microwave won't heat but hums loudly? The diode regulates power to the magnetron. Test with multimeter—reads one direction only. Moderate DIY repair.

More
$26.95

IN STOCK
Ships Tomorrow Guaranteed
Add to Cart

Questions & Answers

For Whirlpool Microwave Diode (Part Number: OEM20352870)

1 Answer

Tim, replace the diode, make sure when you attach the eyelet end to the cabinet frame, sand the area around the screw, and make sure everything is good and tight as possible. Also check and make sure there are no bare metal spots or arc marks on the cabinet frame or area, if there are make sure you touch up the areas with T/U paint. You also want to Carefully test or replace the capacitor.

Read More...

1 Answer

Kim,

In order to replace the diode you will need to pull the unit down from installation and remove the cabinet. Once the cabinet of the unit has been removed the diode will be coming off of the capacitor. There may be a plate that would have to come off to access it on the right side but may be able to see it from the top.

Read More...
Randy for Model Number MH3184XPB0

I have a Whirlpool MH3184XP microwave that does not heat. The last time I used it, I heard a loud crack (high voltage arc to ground?) a few seconds after I pressed run. All other operations (e.g. ventilation fan, control panel, turntable, underhood lights, etc.) seem to be working, just no heat. I tested the capacitor which seems OK. I understand it could be the diode. Where is this diode located? It is not in plain sight when I look behind the control panel.

1 Answer

Hello Randy. You most likely have a "high voltage" side malfunction. Transformer, diode, magnetron, Capacitor. You will need to be extremely careful if you decide to test the components with a multi meter, Very high residual voltage is present, so make sure you remove power to the microwave and short across the terminals on the capacitor. The magnetron should have a reading of less than 1 ohm resistance across the two terminals, and an "open" circuit between each terminal and chassis ground. The diode/rectifier should have a resistance reading in one direction only, no resistance, or resistance in both directions indicate a faulty diode. The primary winding on the transformer should read approximately 450 Ohms resistance, the secondary winding should read 80 ohms resistance, and the filament transformer should read 100 ohms resistance. All of these are +- 10%. If all the readings are proper and in range, replace the magnetron. The diode W11256462 goes from the capacitor to the frame of the unit.

Read More...

1 Answer

Benny,

If you unplug the unit and pull the unit down from installation. You will then need to pull the cabinet off the unit and discharge the capacitor. The diode is connected to the capacitor and screws to the base of the unit.

Read More...

1 Answer

Hello George. You most likely have a "high voltage" side malfunction. Transformer, diode, magnetron, Capacitor. You will need to be extremely careful if you decide to test the components with a multi meter, Very high residual voltage is present, so make sure you remove power to the microwave and short across the terminals on the capacitor. The magnetron should have a reading of less than 1 ohm resistance across the two terminals, and an "open" circuit between each terminal and chassis ground. The diode/rectifier should have a resistance reading in one direction only, no resistance, or resistance in both directions indicate a faulty diode. The primary winding on the trans former should read approximately 450 Ohms resistance, the secondary winding should read 80 ohms resistance, and the filament transformer should read 100 ohms resistance. If all the readings are proper and in range, replace the magnetron.

Read More...

1 Answer

Hello Mark! Unfortunately, we do not carry parts for the brand Emerson and are unable to verify the correct replacement diode needed. Sorry about that!

Read More...

1 Answer

Hello John. Yes, you will need to remove the microwave from the wall to access and replace the parts. You will disconnect the power and remove the outer cover off the unit. The be careful and discharge the capacitor on the unit. Now it is safe to remove the magnetron and diode from the unit and install the new parts. Make sure you discharge the capacitor first.

Read More...

1 Answer

Hello Don. Looking at the door, the diode is on the right side inside the unit. You must remove the outer cover to access and replace the diode.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google