Jim July 09, 2024 for Model Number mhw2000aww I'm working on a 1999 maytag neptune washer model mhw2000aww. It won't fill with water. It will run water for about 2 seconds then stops. When I press the start button it will run water for another 2 seconds and stop. I have to keep repeating the process. I turn the dial to spin and it does the same with the drain pump. It will run for about 2 seconds and stop. Any idea what could cause this?
1 Answer Jim,Check the wiring connections and board connections, and inspect for loose, burned, or broken wires. Also, check the door switch assembly. Read More...
Al August 27, 2019 for Model Number MLE2000AYW I've noticed that on occasion the washer fills higher then normal. I've tested the inlet valve by unplugging the power while in the fill cycle. Water quits filling. Assuming the inlet valve in good. That leaves the Water Level Pressure Switch or hose to the Switch as being the problem. I'm planning on replacing the Pressure Switch and checking the hose at that time. Can you tell me the easiest panel to remove to get to this Switch? I've removed some of the front panels and didn't see the Switch. Where is it located. This is a stackable washer and dryer from Maytag.
1 Answer Al,This one is located in the upper right rear of the washer. You will need the dryer taken down and go in from the top of the washer. Read More...
Rick S February 04, 2015 for Model Number Maytag Neptune Washer- MAH3000AWW In the middle of the wash tumble cycle, all power to the machine will stop and the machine goes dead and trips the circuit breaker. When I reset the breaker and push the start button, some sort of electrical short happens and there is a very distinct ozone burning smell that comes from the control panel. When I remove the back cover, the smell seems to come from the pressure control side of the panel. The motor turs freely and seems to run quietly. Any ideas?
1 Answer Rick, You will want to check the control board that is in the panel and see if there are any burnt resistors. Specifically the R11 resistor. If there is then replace the door lock wax motor and the control board. Read More...
Doug September 09, 2013 for Model Number Mah3000aww Is there any way to check pressure valve, I have blown into it and the water stopped, but I'm not sure if me blowing into it I forced it . Do you know at what psi the valve should operate? Is there any way to test airdome hose, I blew into it and bubbles were coming from tub. Thanks
1 Answer Hello Doug. If you removed the pressure hose from the tub with water in it, you will need to drain the water and remove the hose and blow out the air dome. You willed it with water. If the dome is clear and the hose is good, and the water level does not work properly, you will replace the pressure switch on the unit. Read More...
1 Answer Hello Tony. Based on the model number you provided, W10339251 is the correct pressure switch. Read More...
Jeff R April 18, 2011 for Model Number mah3000aww This machine was purchased in 1999 and the water level seems higher than normal. Should I replace the pressure switch? I recently went thru the entire machine and replaced the belt, tub seal and cover, bearings and seal, the three wax motors, small outer tub hose, and a lot of cleanup Thanks, Jeff
1 Answer Hello Jeff. If the water level is to high, you can check and make sure the hose is not clogged or kinked. If it is good, you will need to replace the pressure switch. Hope this helps. Read More...