George March 01, 2023 for Model Number Whirlpool ED27DQXAB03 I just replaced my defrost timer in my Whirlpool ED27DQXAB03 fridge The New Defrost timer part # is W10822278 It is supposed to replace original part # WP-482493. The old timer didn't have a black wire sticking out of it like the new one does. What do I attach it to? I don't have a white wire anywhere on my modular connector. I tried connecting it to terminal #2 but the compressor doesn't start. What should I look at? Thanks George
1 Answer George, For this model, the black wire will go to terminal number 2 on the timer. Read More...
Dj February 28, 2023 for Model Number Whirlpool Et1chmxkq04 What terminal does the black timer wire attach to?
Muri February 12, 2023 for Model Number 10659782990 I did not receive the instruction manual with the defrost timer W10822278 what terminal is the black wire supposed to be attached to for model 10659782990?
1 Answer Muri,Placement of the loose black wire for the defrost timer: If the timer harness Has a white wire use terminal #1 If the timer harness does not have a white wire use terminal #2 Read More...
Kenny February 10, 2023 Where does the timer jumper wire go on the timer for model ed5fvgxss01 refrigerator?
1 Answer Kenny, The black timer wire will need to be placed on terminal one of the timer. Read More...
Jerry January 31, 2023 for Model Number RS25AGXNQ02 Where does the black wire in the defrost timer go?
Robert January 28, 2023 for Model Number ED0GTKXKQ00 Which terminal does the black wire go to on for defrost timer?
1 Answer Hello Robert, on your model the jumper wire goes to terminal 2 on the defrost timer. Read More...
Anon January 13, 2023 for Model Number ET18GKXGW01 Like others... Which terminal does the black wire connect? I have a Whirlpool ET18GKXGW0-1
Ira January 13, 2023 for Model Number ACD2238HTS Okay simple question I changed everything it would take to make the refrigerator get cool still nothing . Freezer still not getting cold Motors running compressor seem to be on. Could it be the defrost switch not letting it get cold . Or loss of freon in the system No way to check that without placing a tap in. Thanks
1 Answer Ira, as the fans and compressor are operating, the evaporator can be inspected for a frost pattern. If there is not a frost pattern after 30 minutes of compressor run time, there would be a sealed system failure that would require an EPA-certified technician for repair. Read More...
Kl January 09, 2023 for Model Number KSRB25FHBL03 what terminal does the black wire go? and is there thermal fuse and thermostat? can't find them in the frig.
1 Answer KL, There is a defrost bimetal on the evaporator and the black lead for the timer will go to terminal number 2. Read More...