Ion N Winterville , NC September 17, 2017 Appliance: Model RMC257PVS01 Door error and line fuse keeps blowing up each time being replaced Tested the High Voltage Capacitor which showing no capacitance and no resistance. Replaced it together with the diode and the line fuse no longer blew and the microwave is back in service. Read More... 5 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: 30-60 minutes Tools: Nut Drivers, Pliers, Screwdrivers
Margo D Tarpley , TX March 17, 2019 Appliance: Whirlpool 27" Built-In Electric Combo Sensor/Sc (Gold Line) GMC275PDS07 Microwave stated ‘door open’ and would not work. I read up on others with this problem of microwave-wall oven combination Whirlpool Gold. We live in a very rural area and were not able to get ANYONE to service it - had 2 companies come out to inspect but they never returned. I have wonderful news! We replaced the fuse, bus fuse, and light bulb (quit working 2 years ago) and all is working. Thanks for the information and for the part diagram. Couldn't have done it without you. Read More... 2 People found this story helpful Do-It-Yourself Rating: Repair Time Estimate: 30-60 minutes Tools: Screwdrivers