Bob for Model Number RS265TDRS/XAA The refrigerator side doesn't cool and leaks every couple of months. It would fix itself after a day or two. I have tried running "rd" mode or unplugging the whole fridge. I have also taken the panel inside the refrigerator side off before and didn't have any ice build-up. I opened the back panel and it smelled hot and plasticky. However, nothing was melted. The red light on both panels were sold red. No blinking. Should I try replacing one of the boards? Main or inverter PCB?
Answer Bob, the evaporator fan motor DA31-00146E would need to be inspected for any obstructions and, with the door switches activated, tested for 12VDC. If the fan has between 7 to 12VDC when testing from the red wire (using the red probe of a meter) to the black wire (using the black probe of a meter), it should be spinning. During this testing, it is also recommended that the fan is observed to identify if it might be the source of the odor and replace if necessary. If there is not a 7 to 12VDC supply after 60 seconds with the door switches in the closed position, the main control would be the likely cause. If there is a REV number on the model tag, it would be necessary to identify what board is needed. If there is not a REV number, the main control would be part number DA41-00670C. Read More... Answered by AppliancePartsPros.com | Wednesday, April 29, 2020