Refrigerator not cold enough but freezer works? A faulty air damper blocks cold air from reaching the fridge. DIY fix in under 30 minutes with basic tools.

More
$199.79
Compare At:
$237.75
You Save:
$37.96

IN STOCK
Ships Tomorrow Guaranteed
Add to Cart

Questions & Answers

For Whirlpool Refrigerator Air Damper Assembly (Part Number: OEM18019827)

View all Questions

Mario for Model Number KSSC48QMS 02

About a month ago I noticed my freezer was frosted over pretty good and I did not do anything about it at the time. I recently realized that the fridge side was not holding temperature below 42 degrees. I read about similar problems in previously asked questions and I removed the difusser housing and maually opened the diffuser, I guess I will find out in the morning if that was the problem. If so do I just replace the flap mechanism from the fidge side or is there something on the freezer side that needs to be replaced? Also, what would cause my freezer to frost up like it did before everything else happened?

Answer

Hi Mario. Your unit is a self defrosting unit. Every 6-8 hrs / 24 - 7 the unit will turn off the run time and then send 120 vac to the defrost thermostat part # WP2306462 and then if it is closed (normally in frozen temperatures) It will pass the voltage to the defrost heater part # WP2306389. This defrost control board or timer will allow it to stay on for aprox. 20-25 mins. untill the inside temp reaches 40 ° approx. and then the defrost thermostat now opens and stops voltage to the heater protecting cabinet damage. Therefore the damper was more then likely ok unless the damper motor could not regulate the opening / and / closing of the damper. You will need a volt/ohm meter to check the parts. In the frozen temps. your defrost thermostat will be closed-o-ohms. The heater will read resistance of approx. 11-18 ohms, not open. Then you need to advance the unit into defrost and check for 120 vac going to the thermostat and the white neutral wire. This will tell you if the control board is ok part # W10839424. Your wiring diagram is with the controls section. Thank You.

Read More...

Answered by AppliancePartsPros.com   |   Saturday, February 25, 2012

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro

Share your thoughts with other customers

Answer or comment
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store