Giorgio for Model Number GU2300XtvQ1 Water fill valve does not open during the "Rinse and Hold" cycle, but it does open properly during nall other cycles. What could be the problem?
Answer Giorgio, Based on your post information, your most likely issue is a "glitch" in the control board fill valve circuit or the "chip" in the control board WPW10285179. You may want to try conducting the service diagnostic cycle to reset the control " To invoke the Diagnostics Cycle, perform the following key presses or actions in less than 6 sec while in standby: Heated Dry ? Normal ? Heated Dry ? Normal " allow the cycle to advance until it shuts off. " Invoking Service Diagnostics clears all status and last ran information from memory and restores defaults; It also forces the next cycle to be a sensor calibration cycle." If the issue persists, then replace the control board. Read More... Answered by AppliancePartsPros.com | Tuesday, January 8, 2013