Amanda for Model Number REX5634KQ1 We replaced the timer on our dryer and the timer still will not move when we turn on the dryer. Can you give us anymore suggestions on what is wrong with the dryer? Everything works on the dryer but the timer.
Answer Hi Amanda.There is a supplied wiring diagram in the back of the controls area. Use this and see if the wires are not crossed backwards on the timer part # WP8299781. The L-1 black wire connects to the Bk timer terminal. The violet wire connects to the V terminal. All blue wires connects to the B terminal.One black wire from the timer motor will connect to the TM terminal. The White w/black wire connects to the WB terminal. The orange wire connects to the OR. terminal. The red wire connects to the R terminal on the timer. Remove the back. Then check the thermal fuse part # WP3392519 mounted on the blower housing front. All fuses should ohm out closed - not - open. Make sure the vent is entirely clear and not restricted. Make sure the outside vent cap / hood is opening and closing properly 4-5x /yr. so lint and moisture does not back up and create a restriction causing these issues. Thank You. Read More... Answered by AppliancePartsPros.com | Friday, May 4, 2012