If your dryer won't heat properly or runs continuously without stopping, the timer may need replacement. Common DIY repair, moderate difficulty.

More
$164.71

IN STOCK
Ships Today Guaranteed
Add to Cart

Questions & Answers

For Whirlpool Dryer Timer (Part Number: OEM18037776)

View all Questions

Answer

Hello. You will want to make sure you are getting 240V to the unit from the breaker box. Next, check the heating element and make sure the heating coils 279838 on the element are intact. You will want to test the cycling thermostat WP3387134with a multi meter MA-DM1. On the two outer terminals you will want to have a close reading and the inner terminals will give you a resistance reading. Here is a link you can refer to for help with using a multi meter: http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html . Hope this helps!

Read More...

Answered by AppliancePartsPros.com   |   Thursday, May 12, 2011

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro

Share your thoughts with other customers

Answer or comment
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google