** DISCONNECTED POWER FIRST*
I pulled off start relay, and the overload located attached to the side of the compressor. Checked OHMS on 3 pins on compressor. Got continuity through all 3- and NO reading by touching the pins and any copper tubing ,,,compressor was good.
Probable cause was start relay or overload-
Could of metered both to rule out which one-but
neither were too expensive, so opted to replace both rather that doing one and then the other go out 2-3 months later.
Pluged unit back in , and the compressor powered up.