Tim January 29, 2019 for Model Number PH36ZS The halogen lights on my Thermador hood, model number PH36ZS, only come on in the "low setting." The unit beeps when I press the light switch, and all other aspects of the unit are working properly.
Dan November 06, 2016 for Model Number Thermador vcib48jp My ranch hood starts by itself and can't be turned off. In going to the Thermador website with my model number they show an 8 button control module but mine only has six?
1 Answer Dan, According to the manufacturer this control unit 00427159 would be the correct part number for your unit. You will want to double check the model number of the unit to verify the correct model. Read More...
Frank October 22, 2015 Have a Thermador Model ph54zs range hood Serial # 82030049NB Fan will turn on by its self and than I cant turn off runs on hi speed I am tuning it off by the circut breaker Thanks Frank
1 Answer Hello Frank. It sounds like the control board 00427159 is bad and will need to be replaced. Read More...
Rana November 18, 2013 for Model Number Thermador wall hood ph48cs Hello, We have a Thermador wall hood ph48cs that is not working. Looks like the hood vent control made by Bosch is gone bad. I'm looking to replace it. The part has the following numbers on it: Hood Vent Control BSH MAT. NO. 9000000219 120V/60HZ/16A ARK-LES 523 93F 004 E 229814 Date code: 0644 I am trying to find it on your website, but I don't know which part cross matches this one.
1 Answer Rana, The control unit part number for your range hood is part number 00495348. Read More...
Tim September 06, 2013 for Model Number AP2825313 My Thermador PH48ZS has no power to the buttons on the front of the hood. Checking the wiring, I have power coming in from the breaker. Do I have a bad transformer? Or could it be the control unit? Thanks.
1 Answer Hello Tim, This will either be the step down transformer 00189260 or the control unit 00427159. To determine which will be at fault, check the output side of the transformer for 12 volts. If it is there, the issue is the control. If it isn't, replace the transformer. Read More...
Max November 10, 2012 for Model Number PH48ZS It appears I have no power in the hood. I have a remote fan motor on the roof and it had power. Is the control board bad or is there a fuse somewhere? Thanks.
1 Answer Hi. Inside the front cover there is a wiring diagram. The main relay board part # 00427159 receives the 120 vac power on the black and white wires. Use a volt/ohm meter part # MA-DM1 to assist you in your diagnostics. Thank You. Read More...
James December 01, 2011 for Model Number PH48zs Is the wire included in this package? OR Can you purchase just the mother board component?
1 Answer Hello James. No, there is no wiring included with the boards 00427159. The mother board is not sold separately. Hope this helps. Read More...