Ammie December 16, 2020 for Model Number PH30CS Hi, the setting of the the range vent stop working, even on the highest setting, the vent appears to show the same as the lowest. The model number is PH30Cs and the serial number is FD880800015. I was thinking to change the control unit, but I am not sure which is the correct part number to purchase. At the back of the unit, it's showing Bosch Home Appliances Hood Vent Control ARK-LES 523 91F 003 E229814, datecode: 0818, BSH MAT .NO. 9000000574. Please help me out and thank you so much!
Tim November 21, 2020 for Model Number PH36ZS I have a Thermador range hood, model number PH36ZS. When I turn on the lights (not the heat lamps) the dim-light setting works, but the bright-light setting does not. Could this related to the controller or the transformer? Many thanks
1 Answer Tim, while the bright lights are selected, the transformer 00189260 would need to be tested for incoming 120VAC. If there is voltage, then the transformer has failed. If there is not voltage, then the control unit 00427159 has failed if there is not a broken wire. Read More...
Dick O. October 29, 2020 for Model Number Thermador PH30ZS range hood I have a Thermador PH30ZS range hood. It worked perfectly until a day ago. None of the buttons work now. Could you tell me what part is needed? Thanks
1 Answer Hello Dick, This is most likely caused by a bad Control Unit 00427159. I'm sorry but this part has been discontinued by the manufacturer and no satisfactory substitutions have been provided. Thank you for your patience and understanding in this matter. Read More...
Anie June 12, 2020 for Model Number VTR1330E-01 The Fan on my Thermador ventilation has been vert spotty recently but when I pushed on the Bushing Plug it worked for a while but now it stopped working altogether. Do you think replacing the Bushing Plug will solve the problem? Thanks
1 Answer Anie, The bushing plug should not cause the fan to stop working unless it is blocking the scroll from turning. It would be more likely that the fan motor has failed. Read More...
Toby April 29, 2020 for Model Number VCIN36JP I have a Thermador Range Hood (VCIN36JP) with Thermador Blower (VTN1030N). The fan will randomly turn on, change speed setting, and cannot be shut off. Can you tell me what replacement part and number I need to purchase? Thanks.
1 Answer Toby, The most likely cause for this issue will be a faulty control module part number 00659369. Read More...
Marc March 17, 2020 for Model Number PH48ZS Hi. Low speed does not work but medium and high do. Everything else works perfect. Thoughts? Thanks
Nitin M. February 27, 2020 for Model Number PH36G We have a Thermador PH3G hood attached to a VTR1330E 1000 Cfm dual-fan external blower. After about 4 years, one of the fans in the blower started making a terrible racket. I disconnected it and the other fan appeared to work fine. Sometime later I replaced the failed fan with a new OEM fan (fan, capacitor, and wiring) and within a week the remaining old fan started acting up. I have disconnected it and am using the blower with one (new) fan. Could the fan failure be due to the electronics in the hood and if I replace that will the second fan be usable? Thanks
1 Answer Nitin M.You will just need to replace the other fan. Probably the bearings in the motor are what you are hearing. Read More...
Fernando September 21, 2019 Hi there, I'm looking for this part that has the following numbers on it: Hood Vent Control BSH MAT. NO. 9000000219 120V/60HZ/16A ARK-LES 523 93F 004 E 229814 Date code: 0531. I found some similar in your web answer with part number 00495348 if you look for it in your web, it shows a part diagram in that diagram the part that I'm looking for is 0207. How I can find it? thanks.
1 Answer Fernando, if the model number for this appliance could be provided in a new inquiry, this will allow for the most accurate information to be presented. Read More...
Kirk April 17, 2019 for Model Number PH36CS I have a Thermador PH36CS hood with the VTN1030N blower fan. The fan has started to run at about half speed on all three speed settings. So at high speed it runs at about half what it should. At slow speed it barely turns. Would this be a fan motor issue or a control board problem. Thanks.
1 Answer Kirk, while it may be possible that the control is not sending the proper voltage to the vent motor, the motor [00448364] should be tested to ensure that it is in good condition. Read More...
Ernie March 06, 2019 for Model Number PH36GS/04 1. Rt side halogen light goes off but tapping it turns it back on, replace bulb and socket? Pn? 2. Both halogen lights come on but do not dim even though the led say they are on. Replace transformer pn? 3.Now unit comes on all by itself and cycles repeatedly thru lights, fan, off and can not be stopped. Turning power off and on does not reset, unit just starts the cycle again. Replace 8 button control board pn? 1-off 2-fan speed 3-auto 4-delay 5-filter reminder 6- light on/dim/off 7-heat lamp lt 8- heat lamp rt 4. How do I remove and replace the 8 button panel?
1 Answer Ernie, it is possible that the halogen bulb is not inserted fully or there may be a wiring issue. The part number for the bulb and socket is [00620803]. Based off of the wiring diagram the main control [00655614] should be what is sending voltage directly to the lamps and would be responsible for dimming them. The main control is also more than likely going to be responsible for the cycle being repeated. The controls can be accessed by removing the filters and removing the retaining nuts on the inside of the hood. It is recommended to do this with the unit unplugged. Read More...