For Bosch Control Unit (Part Number: OEM8514228)

1 Answer

Murray, You will want to double check the wiring to ensure that everything has a firm connection. Also check to make sure that there are no pinched or broken wires. Check for power at the control board going down to the recirc. pump and if there is no power then replace the control module. If there is power and the wires are good then you will need to replace the recirculation pump.

Read More...

1 Answer

Madelyn, If the water is not hot, then you will need to check the heating circuit to make sure that power is going to the heater. If there is no power going to the heater then check the thermistor. If the thermistor checks ok then you will need to replace the control board.

Read More...

1 Answer

Hello Kenny. Based on the information you provided, it sounds like you will need to order and replace the control board in the unit.

Read More...

1 Answer

Hello Chris! Yes, the control unit 00489004 is the correct replacement control used on your Bosch model SHX33A06UC/14. Thanks!

Read More...

1 Answer

Hello Bryce, You will want to check to see if the oven ignitor is working. You do this by testing the amp draw on the ignitor. You should have 3.2 to 3.6 amp draw. If you do not have within this range then the ignitor is bad and will need to be replaced. You will also want to do a voltage test at the control board from connector P2 to Neutral for 120 vac to make sure that control is sending power to the ignitor.

Read More...

1 Answer

Hello Bryce, You are most likely not hearing the circulating pump, but the drain pump. If you remove the water valve you can use the opening to check for water in the base. Most of the time on this design, the water valve isn't opening all of the way and a dribble of water into the base has activated the flood switch. In this case, the water valve 00425458 replacement and drying the water from around the flood switch float will correct the situation.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • boxes images Over 2.1 Million Parts In Stock
  • time delivery images 2 Day Quick Delivery!
  • box-refresh images 365 Day Return Policy!
  • headphone imagesFree Tech Support!
  • google images Google Trusted Store