Tom November 03, 2013 for Model Number LFFU17F5HWC Hello, This freezer belongs to a friend and asked me if I would check it. I checked the compressor and cap. Then both check fine with a meter. The control panel on the front looks fine. The freezer doesn't do anything, it just sits there. No alarm, no high temp light, & no door agar light. You can raise the temp, turn it off, & so on. My friend explained to me they had a power outage, & when the power come back on, the numbers on the LED were scrambled. She unplugged it and plugged it back in, & then it had a dash here and there but that was it. She tried it again & the numbers come back. That is how it is now but still nothing. I am thinking it is the control board. I took it out & inspected it & see nothing that looks burnt or damaged. I am thinking it is the control board, is there a way I can be sure. Thanks Tom
1 Answer Tom, Based on the information it does sound like the control board is bad and would need to be replaced. There really is not a test but if nothing is getting power then the control board would be the issue. Read More...
David October 11, 2013 for Model Number lffu14f5hwa What would cause a freezer is turning itself off? Did it the first time a couple of weeks ago. Did twice more this week. Freezer is only 5 years old.
1 Answer Hello David. You will need to replace the control 297370600 on the unit to repair the unit. Read More...
José L. O September 19, 2013 for Model Number FFU17F5HWE The freezer stopped working one week ago. The compressor does not run, the fan does not run, the touch pad display "F". after that becomes "0". What do you recommend to do?
1 Answer Jose, The O and then F is an indication that the unit is turned off. Push the up button and hold for 3 seconds to see if it will come on. If not then you will need a new control board. Read More...
Greggy September 13, 2013 for Model Number FFU21F5HWB Hello, When the door gets closed I can't hear the air noise coming from the freezer. I think it is some kind of air suction pump that makes the door seal better when close. Negative air inside? How do I fix it? Replaced the door seal alreday but still it doesn't keep the door seal tight. Thanks!
1 Answer Greggy, You will want to check to make sure that the defrost drain is not clogged up. If it is the unit cannot extinguish the air and pull the door tight. Read More...
Dulac September 11, 2013 for Model Number LFFU17F5HWA My upright is approx 5 yrs old and one morning I had water all over the floor in front of it. The digital display was off. I unplugged the unit and when replugged it came on. A few days later it happened again.. I did the same thing. A few WEEKS later there were all kinds of letters lighting up on the display and the freezer wasn't on. I emptied it. I took the control off the door took it to work with me so I could order another one. No luck! Came home 7 hours later and out of curiosity I placed the control back in the door and it is working at the moment. ????? How do I test the control to see if there may be something else wrong?
1 Answer Dulac, The most likely cause is that the control board is sticking when the unit goes into the defrost cycle. With the symptoms that you provided it would be best to replace the control board as this issue will happen again. Read More...
William September 04, 2013 for Model Number LFFU14F5HWL Freezer The freezer only works on no. 2 setting. When I put it on 3-7 the freezer gust keeps running and won't shut off . I think I need a control Board. William
1 Answer Hello William. If the thermistor 297018400 is good, you will need to replace the control board in the unit. You can test this with a multi-meter TJMA-DMT3. Here is a link on how to use a multi-meter. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html Read More...
Peter August 28, 2013 for Model Number Frigidaire lffu14f5hw Frigidaire Upright Freezer, basement got water in it and freezer control panel now shows red leds on for the door ajar and high temperature. Alarm also sounds for door ajar. Switch to turn off light also does not work. Freezer is still running fine, I checked the internal temperature and it is fine. I think I need to replace the main control panel on front of freezer, but what else should I consider replacing? The door switch for turning off the light? The wiring harness that most likely got wet? Any other parts of the freezer that may be faulty now and I may not know it yet? Also if I need to replace the switch mentioned, could you provide the part number?
1 Answer Peter, The main control board is the biggest thing that you would want to replace. If the light switch is not working then you would want to replace it as well. Anytime a unit gets flooded, any electrical component can be damaged. If the unit is working for now then you will only need to replace the ones that currently damaged. Read More...
Jeff August 22, 2013 for Model Number LFFU17F5HWH The freezer stopped working after 1.5 years. The compressor does not run, the fan does not run, and the numbers on the touch pad are not reconizable. The interior light comes on, and when the freezer is plugged in, it gives several quick beeps. What do you recommend changing first?
1 Answer Hello Jeff. Based on the information you provided, the control board 297370600 is bad and will need to be replaced on the unit. Read More...
Jesus M August 01, 2013 for Model Number FFU14F5HWN The control board is only partially lit, and the fan and the compressor no works, the light inside work. I change the starter but continue with the problem no run.
1 Answer Jesus, If you only have partial display and compressor and fans not running, this would be caused by a bad user interface 297370600. Read More...
Repair Tech July 13, 2013 for Model Number Electrolux/Frigidaire LFFU14F5HWD control bd. 297241800 Unit suffered control board failure due to power surge. Replaced bad capacitors (220uf/35v and 1000uf/16v). Unit now partially functional (boots up and arrow keys cycle display from 0 to 7 but high temp/door ajar alarm does not sound and compressor does not come on). Unit beeps 3 times upon boot up (error code possibly). Need schematic, beep codes/service info for this controller if possible. Customer P/N :297241800 Selcom P/N : 451704000 MFG Date Code WKD8-09 Software Version : 1.3
1 Answer Repair tech, In order to be able to send any wiring information we would need an email address to send information to. If you are looking for a spec sheet for just the components on the control board, we would not have that type of information available. Read More...