Skip to Content
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Trusted Since 1999 Trusted Since 1999
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google

Customer Questions and Answers for Refrigerator Freezer Electronic Control Board (White) by Frigidaire

Best Seller
Manufacturer Part
4.89 (64)
By: Frigidaire
Part Number: OEM15956754
Manufacturer Part Number: 297370600

This electronic control board includes the user-facing touch pad display panel and the circuit board that manages freezer temperature settings and functions. It mounts on the exterior of the freezer compartment and allows you to adjust temperature and other settings. Replace this board if the display is blank, unresponsive, shows error codes, or if the freezer is not maintaining the correct temperature despite other components working properly.

More
$118.95

IN STOCK
Ships Tomorrow Guaranteed
Add to Cart

Questions & Answers

For Frigidaire Refrigerator Freezer Electronic Control Board (White) (Part Number: OEM15956754)

1 Answer

Hello John. It sounds like the control board part# [297370600] will need to be replaced.

Read More...
Michael for Model Number Model#LFFUI7F5HWB PN# 297241800/sn#WB82834280

I have a Frigidaire freezer. It looks like it was made in 2008. Bought it new in 2013. The temperature control on the outside of the door blinks and clicks and the two red alarms on the temperature control, door ajar and temp hot, blink. No control/readout on temperature control to change temperature and it will not react when I reset it. The freezer is not coming on. Do I have a bad temperature control? Thanks!

Becky for Model Number FFC25C8CW0

Freezer makes sound for a few seconds then cuts off but the compressor never kicks on. Thought it was the run capacitor per a couple other sites but that did nothing to fix it. Initially realized it wasn't cooling because the built in alarm sounded. The light for the alarm is flashing but the power light is off. The power light will light up while holding down the alarm on/off button however the alarm will not turn off. Could it be the control panel causing the problem? Thanks.

Becky for Model Number FFC25C8CW0

Freezer makes sound for a few seconds then cuts off but the compressor never kicks on. Thought it was the run capacitor per a couple other sites but that did nothing to fix it. Initially realized it wasn't cooling because the built in alarm sounded. The light for the alarm is flashing but the power light is off. The power light will light up while holding down the alarm on/off button however the alarm will not turn off. Could it be the control panel causing the problem? Thanks.

2 Answers

Hello Becky,
This sounds more like the start device 5304491583 on the compressor. If you remove it from the compressor and it rattles when you shake it, it will be the issue.

Read More...
Jesse C for Model Number FFU14F5HWA

We have had our freezer for roughly 5 years. The unit first started acting strange about a month ago. On occasion, the compressor would be running and we would open the unit and the interior light would go off and the display panel would start blinking and the unit would not come back on. I would unplug the unit for about 30 minutes and it would start working again. Today however, it has done something different. Both the high temp light and door ajar lights are blinking rapidly and making a buzzing sound when the unit is plugged in.

1 Answer

Hello Luther,
The control board 297370600 for this unit comes as an assembly and individual parts for it are not made available by the manufacturer. If you are referring to the box the control board snaps into, this is made in the door assembly 297316501.

Read More...

1 Answer

Hello Ebbie,
For model number LFFU17F5HWC, the electronic control 297370600 will most likely be the issue. If it doesn't correct the issue, you can return it as long as it is within 365 days from the date of order.

Read More...
Mark for Model Number FFU17F5HWD

Freezer doing many strange things. Model # FFU17F5HWD. Getting both error lights on the front display. The alarm sounds sometimes, other times not. Sometimes the freezer is running, sometimes not? Got an "E" once on the display? When I open the door the inside light blinks? The food inside the freezer is thawed when I get the high temp light, so that error message is correct. When I reset the power at the control box, it starts running fine for awhile then starts doing these things again. Sometimes the number on the door panel is not lit up and the unit is running continuously? Other times the high temp alarm is sounding, and the freezer is not running at all? It does then reset OK for awhile, but then continues to act up? I put in a service call, the repair guys came while it was running fine after a reset done the night before. They said they could not check it until the unit was doing something wrong? Charged $70.00 for nothing! After they left, it started having the usual problems again the next day? I should mention this all started a few months ago after a bad lightning storm, the light inside the freezer went out, and number display on the front control panel showed nothing or was not lit. I replaced the bulb on the inside of the freezer, which did not fix the problem. I went to the Frigidaire website and the problem, when both the control panel and inside light are out, was stated as "no power getting to the unit" even though it was running while these two problems were occurring? I found a statement somewhere that said this reaction by the unit is part of an error message to give one time to make a service call if power does become restored to the freezer? Next I should mention how I have checked the electrical outlet the freezer is plugged into. I plugged an electric drill into the outlet plug the freezer is using, and the drill ran fine in both plugs on the outlet in question. I also plugged the freezer into the lower plug on the same outlet, and I had the same problems over time? I am considering running an extension chord to another electrical outlet in the garage to see if the freezer still has problems? I read where I should not, but am desperate. Its either the outlet is cutting power to the freezer randomly or the freezer unit is the problem. I read where the control boards go bad, but does that error cause all these inconsistent crazy problems? Sorry about the long-winded message, but I need advice. Please help.

1 Answer

Hello Mark. Yes, your control board is bad and will need to be replaced in the unit.

Read More...

1 Answer

Hello Marvin. It sounds like you may have a defrost problem with the unit. Check and see if there is any frost build up on the evaporator coils in the freezer. If so, you will need to test the defrost heater and the defrost thermostat. They should read closed for continuity when cold. You can test this with a multi-meter TJMA-DMT3. I will include a link at the end to assist you how to use the multi-meter if needed. If both parts are good, you will need to replace the defrost timer. Once the problem is repaired, you will need to thaw out the ice on the coils before the unit will operate properly. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html

Read More...

1 Answer

Hello Ted. You need to look for a bad connection on the unit. A bad wire or connection will cause the issue you are having with the unit.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278