Questions & Answers

For Ge Refrigerator Defrost Timer (Part Number: OEM6185094)

Dave R for Model Number TPS24BPDB BS

My evaporator is frosting up. Every couple of months I need to unplug the refrig and let it defrost. The timer seems to be okay. I can turn it until the fan and compressor stops. I wait about a half hour and the compressor and fan start backup. Should I be able to feel warmth on the rear of the freezer section when I turn the timer to the defrost cycle? (I do this while the freezer is still cold). I was thinking of just replacing the heater and thermostat assembly. The refrig is a GE model TPS24BPDB BS. This model does not should on you list of models. The closest model is TPS24BPDA BS. Is this model the same as the TPS24BPDB BS? I think the refrig is over 10 years old. Should I replace the timer as well? Thanks Dave

1 Answer

Hello Dave. It sounds like you may have a defrost problem with the unit. Check and see if there is any frost build up on the evaporator coils in the freezer. If so, you will need to test the defrost heater and the defrost thermostat. They should read closed for continuity when cold. You can test this with a multi-meter TJMA-DMT3. I will include a link at the end to assist you how to use the multi-meter if needed. If both parts are good, you will need to replace the defrost timer. Once the problem is repaired, you will need to thaw out the ice on the coils before the unit will operate properly. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html

Read More...

1 Answer

Hello PT. Make sure the condenser fan motor is running and the coils in the back are good and clean. It sounds like you may have a defrost problem with the unit. Check and see if there is any frost build up on the back wall of the freezer. If so, you will need to test the defrost heater and the defrost thermostat. They should read closed for continuity when cold. You can test this with a multi-meter TJMA-DMT3. I will include a link at the end to assist you how to use the multi-meter if needed. If both parts are good, you will need to replace the defrost timer. Once the problem is repaired, you will need to thaw out the ice on the coils before the unit will operate properly. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html

Read More...

1 Answer

Hello Joe. Based on the information you provided, it sounds like the temp control WR9X569 is bad and will need to be replaced.

Read More...

1 Answer

Hello Barry,
If the food is only freezing in the crisper drawers and near the bottom of the unit, the issue is most likely the temperature setting. Refrigeration is backwards so think of it this way. Cold air is heavier than warm air. If the fans are not running, the cold air will equalize at the bottom of the unit. This will make the items in the bottom of the unit freeze on the fresh food side and the top of the unit will warm up on the freezer side causing slow or some times no ice production. The cure for this is to set the fresh food side to a colder setting which will make the unit kick the fans on more often and circulate the air inside the unit. If this is still too cold, try setting the freezer a number warmer.

Read More...

1 Answer

Jacob,

The terminals 1 and 3 are for the timer motor and if the timer is not advancing and you have no continuity on these terminals then the timer is faulty and would need to be replaced.

Read More...

1 Answer

David, the defrost control part number WR9X489 is located in the refrigerator section behind the control housing. Thanks.

Read More...

1 Answer

Mom,

It sounds like the defrost timer may be sticking during the defrost or the fan operating during the defrost. This would be caused by a faulty defrost timer WR9X489.

Read More...

1 Answer

Bob,

You will want to check the damper door to make sure that it is open. It sounds like the damper WR9X522 is not opening and would need to be replaced.

Read More...

1 Answer

Hello Sam. If it was just the bottom, and there was no frost on the top of the evaporator, you have a sealed system issue, and not a defrost issue. You will need an HVAC tech to repair the unit.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google