For Ge Cooktop Spark Module (Part Number: OEM21648372)

1 Answer

Steve, You're going in the right direction, when you turn on any valve all the igniters should spark. You'll need to check the wires to the two igniters that don't spark, make sure they're not broken or shorted to the chassis and replace the spark module WB13X46909 if alls OK.

Read More...

1 Answer

Hello Bill, When only one surface burner isn't working, it is normally because of a dropped ground. The ignitor has to have a good ground to spark to, as you know the circuit has to be complete back to ground. The cook top is made up of multiple steel parts, all screwed together. The way I usually restore normal operation is to remove all of the parts that are screwed together and use a piece of 120 grit sand paper to "clean" the surfaces that contact to complete the ground up to the ignitor area. This will solve the issue 99% of the time. The other 1% is a bad ignitor, start switch, or spark module. Since you have replaced them already, the ground will be the issue.

Read More...

1 Answer

Richard, Disconnecting the electrode wires, is not going to pin point the problem. You need to test for 120 VAC on the end of the red wire at the spark module to chassis ground, with all the switches in the off position. If you have voltage on the wire, you have a bad switch and need the WB18T10452 switch abd harness assembly. If you have no voltage on the wire, then you need the spark module WB13X46909

Read More...

1 Answer

Hi. If one of the control valve spark switch is shorted then it will create non-stop ignition. It is part # WB18T10343. All 4- switches are daisy chained together to replace them all at once. Use a volt/ohm meter part # MA-DM1 to assist you in your diagnostics. Disconnect the power and ohm out the switches one at a time by removing the wires and testing on the ohm R x 1 Scale for a open switch (Infinity- too great of a measurement to read) Physically in the off position. If it reads 0-ohms (0.1 /0.2 ohms) then it means the switch is shorted (already closed to allow the voltage to pass). In the off position the switch will read open(Infinity). In the on position it will read o-ohms or as close to it can as mentioned before. These are the normal parameters. Anything else means that the switch is shorted in the off position. If the units electrical plug was turned upside down, then the reverse polarity will create the same symptoms. Thank You.

Read More...
Kjp2u for Model Number JGP328BEC2BB

The manufacturer replacement spark module no longer has a connection for the ground wire as the original did. How do I connect the ground from the cooktop to the spark module? Also, where do I get the actual wires that connect an igniter to the spark module. One of them got melded into an igniter and the wire broke. They side that inserts into the igniter is a unique connection and I'm unable to find that connection or wire anywhere! Those particular wires don't show on the diagrams. Help! Thanks!

1 Answer

KJPU2, You will not make a connection to ground. The grounding to the spark module will be completed by a circuit to the neutral leg of the power supply, in the new module circuitry. Thanks

Read More...

1 Answer

Hi Tom. I would use a volt/ohm meter part # MA-DM1 to assist. you in your diagnosis. You can only see if the burner switch when on sends full voltage (120 vac) to the positive and neutral of the ignitor module. The output is unmeasurable at 10,000 -to - 14,000 vac to each spark ignitor part # WB13T10073. If the wires are not pinched and the circuit damage is corrected and a tight connection. The spark module internal coils will also back up and short out . Part # WB13X46909. Thank You.

Read More...

1 Answer

Hello Kevin. Check and see if the igniter is cracked or broken. Also, make sure it is clean and dry. If so, and it reads closed for continuity, you will need to replace the spark module WB13X46909. Hope this helps.

Read More...

1 Answer

Hello! It looks like this part is installed by first removing the main top of your unit. To do this, remove all the burner grates and burner heads. This should reveal all the screws needed to separate the top from the lower section. Under this top you should be able to see the spark module clearly. It looks like only a few screws hold this part in. I hope this info helps!

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form