This power control board is a genuine Samsung part, sold individually. This power control board is a replacement part for a refrigerator. The power control board is located in the back of the refrigerator. The purpose of a power control board is to maintain and manage the refrigerator's compressor. If a refrigerator is not maintaining its temperature properly, the power control board may need to be replaced. This type of board has an LED light that will signal if it is not functioning correctly. If this LED light is going off, the power control board should be removed and replaced with this genuine OEM replacement part. The repair or replacement process for a power control board is simple to perform and will require no specific tools. Make sure to wear gloves while performing this replacement for safety when dealing with electrical currents and potentially hazardous materials. This is an OEM part sourced directly from the manufacturer. This power control board is compatible with Samsung brand refrigerators.

More

Questions & Answers

For Samsung Power Control Board (Part Number: OEM14945724)

1 Answer

Gary, you will want to check the freezer thermistor to ensure that it is reading properly. If the thermistor failed and senses around 0 degrees, then it will have the control think that the freezer is at temperature. If the sensor [DA97-02019B] tests good, then we will want to look towards the main control [DA41-00538A].

Read More...

1 Answer

Badih, This issue would be caused by a motor locked which would require the compressor to be changed out.

Read More...
Matthew for Model Number RF24FSEDBSR/AA-0000

My refridgerator isn’t cooling in both compartments. I have replaced the condensor fan, compressor fan, and still get no cooling. My compressor or compressor fan is not turning on. When I plug the fridge in I get one light blink on the inverter board and then it stays off. I have tested and I know I’m getting power to both the fan and The compressor. It’s just not turning on. The condensor fan works fine. All lights and control panel in the front work with no problems. Could it be the Inverter board needs to be replaced? Thank you so much for your help!

1 Answer

Matthew, you may want to check the compressor overload to ensure that it is functioning properly. If the compressor is receiving 120VAC, then either the overload, relay harness, or compressor are bad. You can test the overload for continuity. You can test the compressor resistance by testing the top pin as the common and testing to each of the lower pins. The resistance for both pins to the top pin should be the same.

Read More...

1 Answer

Mary, if you can post another question and include an e-mail address, I can send you some information as to diagnosing your refrigerator issues. Thanks

Read More...

1 Answer

Jane, what you will want to do is test at connection CN103 pin 1 and 3 for voltage ranging between 2-3VDC. If you are getting voltage, then your compressor has locked up or has a restriction.

Read More...
Jgreer

I have a 6 year old Samsung RFG298AARS. The temperature in both the fridge and freezer recently began to fluctuate drastically. When diagnostics are performed, no errors are returned. The compressor and condenser fan are working. There's light frost on the condenser coils, and there's no ice inside the compartments. The fans inside both the fridge and freezer are working fine. The temps read 2 freezer and 32 fridge, even when they are warm. If I unplug wait 5 min and plug back in, it runs fine for a short time and then warms up again and temps still read 2 and 32. I replaced the PCB and afterwards, the panel finally read 50 freezer and 74 fridge. Everything worked great.......for 3 days, but I got up this morning to a warm fridge....and the temps read 2 and 32 once again. Both compartments are empty. Any ideas?

1 Answer

JGreer, You will want to check the temp sensors at room temp for a resistance of 5K at room temp.

Read More...
Bob

Samsung rf267aewpxaa refrigerator & freezer not working. Refrigerator iced up. Unthawed & worked for 2 days (freezer still not working). unthawed refrigerator & replaced temperature sensor on fan, temperature sensor on evaporator coil & defrost thermostat & defrost heater.Refrigerator worked but still icedup. Freezer still not working. Call & asked what the problems could be & said I needed a main board (da41-00651t.) Worked - no more icing in refrigerator but freezer still not cooling only to 58 f . Fans work in freezer also fan for compressor works. Only things I haven't ordered is a overload protector for compressor ,defrost heater for freezer & sub inverter board da41-00614f. Can you help? Compressor seems to be working since refrigerator is working. Help!!!

1 Answer

Bob, You will want to pull the rear wall of the freezer compartment and check to see what the evaporator frost pattern looks like. If it is completely iced up then the issue will most likely be a defrost sensor or bimetal that is faulty. If there is very little to no frost pattern then this would be a sealed system type of issue and will need service.

Read More...
Pete for Model Number RFG237ACRS

7 year old fridge has been intermittently not cooling. Compressor will fail to turn on maybe once every couple of weeks for an unknown length of time and I would notice things in the freezer starting to thaw but the next day everything would be fine. Lately it is happening more often and lasting longer - to the point where everything thaws out. I am getting one blink on the diagnostic LED. Everything I have read leads me to believe the inverter board needs to be replaced, but I'm wondering if it could be anything else?

1 Answer

Pete, one blink on the inverter board represents a starting failure on the compressor. I would recommend replacing the inverter board, part number is DA92-00215C

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • Over 2.1 Million Parts In Stock Over 2.1 Million Parts In Stock
  • 2 Day Quick Delivery! 2 Day Quick Delivery!
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Google Trusted Store Google Trusted Store