Ken June 24, 2018 for Model Number RF32FMQDBSR/AA-0000 The ice maker stopped working (producing no ice) and then about 5 days later, the freezer stopped working. This is a dual compressor model - so 2 inverters. The top inverter LED is on constant, and the lower inverter LED is off (not flashing.) Both compressors seem to be operating (warm or hot) and the evap fan is running. Everything else seems normal - the front panel is working and the refrigerator is operational. Thinking the lower inverter board is broke?
1 Answer Ken, This issue would most likely be caused by a faulty stepping valve which would be part number DA97-08630B. Read More...
Ralph June 14, 2018 for Model Number Rf34h99604/aa Refrigerator not cooling constant red light on first inverter board18. Inverter fan running no ice.
1 Answer Ralph, If there is no ice on the evaporator of the refrigerator then the issue will be a sealed system problem and will need to have service. Read More...
Nick April 15, 2018 for Model Number RF266ABBP/XAA Hello kind, generous, knowledgeable, techs! My unit isn't cooling at all. The fuse on the main control board looked blown and is now replaced, also on main control board the red led is flashing. Condenser fan is running but the compressor isn't engaging. All other functions appear normal. What do I need to do next to put the cold back in the Samsung heart?
1 Answer Nick, The led light flashing on the inverter would be a error code and will most likely be caused by a faulty inverter. Read More...
William March 29, 2018 for Model Number RFG298AARS/XAA samsung The top ice maker is not getting water. I have replaced the ice maker and the water valve. The red light is not on at the inverter control board. Could this be the problem? Thanks
1 Answer Hello William, If the compressor is running and the unit is cooling, the light on the board will not be an issue. You should verify voltage to the icemaker and to the water valve for about 7 seconds near the end of the cycle. The issue is most likely going to be a connection or harness issue. Read More...
Zahid March 11, 2018 My samsung wont work at all. Backside on main p c b led is blinking 10 times. What is the problem. Its inverter comp refrigerator
1 Answer Zahid, We will need to have the model number of your unit to be able to assist with your question. Read More...
Robert March 08, 2018 for Model Number rfg297arrs My refrigerators not cooling the back board led light is not on. Could I replace the board series # ap4981905.
1 Answer Robert, You will want to make sure that the inverter board is getting 120 vac to it and if it is but the light is not on then the inverter will need to be replaced. Read More...
Milkin February 20, 2018 for Model Number samsung rf266abpn I have a samsung refrigerator model rf266abpn that doesn't cool, neither the fridge or the cooler, in the back small board a light blinks 5 times and the fuse on the same small board is blown (bad).. i replace the fuse and it blown again..what it could be?
1 Answer Milkin, With the fuse blowing after replacing it then this would be a faulty inverter board on the unit. Read More...
Dave January 23, 2018 for Model Number RFG237AARS/XAA-0000 Neither the refrigerator or freezer are getting cold at all it started working after unplugging but then failed after 3 days with no errors the compressor and fan are running and I have 10 ohms across the compressor pins. The red light on the inverter pcb is on steady. I have 2.5 volts on CN75 pin 4, I can feel the step motor valve running when I plug in the refrigerator and I have 40 ohms across the coils.Do you have any recommendations on what the problem might be.
1 Answer Dave, With the compressor running but the unit not getting cold it would be recommended to have service out to check for a sealed system issue which will be the most likely cause. Read More...
Scott December 08, 2017 for Model Number RF267AERS/XAA-0001 Refrigerator The screen changes temperature by itself and now it shows "OF" (demo mode) on both sides, so the fridge and the freezer is not working at all. What it can be, the PCB sub inverter or the PBA panel?
1 Answer Scott, You would want to get the display pcb part number DA41-00463E for this issue. Read More...
Eric October 04, 2017 for Model Number RF263AEBP/XAA I have no power at all, is it the PCB sub-inverter or the PCB main? When I plug it in the red light on the PCB sub-inverter comes on then goes right out not to come on again.
1 Answer Eric, This issue would be caused by a faulty main pcb which will be part number DA41-00651R. Read More...