This power control board is a genuine Samsung part, sold individually. This power control board is a replacement part for a refrigerator. The power control board is located in the back of the refrigerator. The purpose of a power control board is to maintain and manage the refrigerator's compressor. If a refrigerator is not maintaining its temperature properly, the power control board may need to be replaced. This type of board has an LED light that will signal if it is not functioning correctly. If this LED light is going off, the power control board should be removed and replaced with this genuine OEM replacement part. The repair or replacement process for a power control board is simple to perform and will require no specific tools. Make sure to wear gloves while performing this replacement for safety when dealing with electrical currents and potentially hazardous materials. This is an OEM part sourced directly from the manufacturer. This power control board is compatible with Samsung brand refrigerators.

More

Questions & Answers

For Samsung Power Control Board (Part Number: OEM14945724)

1 Answer

Ralph, If there is no ice on the evaporator of the refrigerator then the issue will be a sealed system problem and will need to have service.

Read More...

1 Answer

Nick, The led light flashing on the inverter would be a error code and will most likely be caused by a faulty inverter.

Read More...

1 Answer

Hello William, If the compressor is running and the unit is cooling, the light on the board will not be an issue. You should verify voltage to the icemaker and to the water valve for about 7 seconds near the end of the cycle. The issue is most likely going to be a connection or harness issue.

Read More...

1 Answer

Zahid, We will need to have the model number of your unit to be able to assist with your question.

Read More...

1 Answer

Robert, You will want to make sure that the inverter board is getting 120 vac to it and if it is but the light is not on then the inverter will need to be replaced.

Read More...

1 Answer

Milkin, With the fuse blowing after replacing it then this would be a faulty inverter board on the unit.

Read More...
Dave for Model Number RFG237AARS/XAA-0000

Neither the refrigerator or freezer are getting cold at all it started working after unplugging but then failed after 3 days with no errors the compressor and fan are running and I have 10 ohms across the compressor pins. The red light on the inverter pcb is on steady. I have 2.5 volts on CN75 pin 4, I can feel the step motor valve running when I plug in the refrigerator and I have 40 ohms across the coils.Do you have any recommendations on what the problem might be.

1 Answer

Dave, With the compressor running but the unit not getting cold it would be recommended to have service out to check for a sealed system issue which will be the most likely cause.

Read More...
Kat for Model Number RFG298AABP/XAA

Fridge and freezer stopped cooling. Checked for error codes -none displayed. Condenser fan working. On PCB steady red light. Spoke to repairman over telephone and he said from his experience the compressors on these fridges only last 6-7 years and the cost for him to come out and look at the fridge and repair it would be $500-$700. I said I would think about it. He then called and asked me to check if it was in store dispay mode. I checked and it is not. Wonder if it is the relay O/L or the inverter board Should I order both or check if it is the relay O/L first?

1 Answer

Kat, This issue would not be caused by the overload relay because it has a inverter board which controls the compressor. TEST BEFORE INTERPRETING LED BLINKING FREQUENCY Compressor not running 1. Activate Forced Compressor Operation, wait 2 minutes (in case of high head pressure) 2. If compressor doesn’t start, check CN75 for 2.5vdc (if not there replace Main PCB) 3. If voltage is OK, remove power, disconnect CN03 (Inverter PCB) and check resistance to the windings. Aproxametly10 ohms. If not correct , inspect wire harness, if OK replace compressor.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • Over 2.1 Million Parts In Stock Over 2.1 Million Parts In Stock
  • 2 Day Quick Delivery! 2 Day Quick Delivery!
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Google Trusted Store Google Trusted Store