This power control board is a genuine Samsung part, sold individually. This power control board is a replacement part for a refrigerator. The power control board is located in the back of the refrigerator. The purpose of a power control board is to maintain and manage the refrigerator's compressor. If a refrigerator is not maintaining its temperature properly, the power control board may need to be replaced. This type of board has an LED light that will signal if it is not functioning correctly. If this LED light is going off, the power control board should be removed and replaced with this genuine OEM replacement part. The repair or replacement process for a power control board is simple to perform and will require no specific tools. Make sure to wear gloves while performing this replacement for safety when dealing with electrical currents and potentially hazardous materials. This is an OEM part sourced directly from the manufacturer. This power control board is compatible with Samsung brand refrigerators.

More

Questions & Answers

For Samsung Power Control Board (Part Number: OEM14945724)

1 Answer

Hello Moses. You will need to try resetting the unit. Unplug it for about 20 minutes then plug back in. If the issue continues, then the main board may have failed and will need to be replaced on the unit.

Read More...
Ken for Model Number RF266-AEBP

Refrigerator at this time has a bad evap. fan motor, getting 9 v DC but not running. other than that have a issue with digital readout blinking on left side a steady 88 and on right from 88 to 86, frige runs fine but i do not know what my settings are. buttons will still change temp , verified by temp. change taken with meter. Main board has been changed and also digital display. I have been running it this way for about 3 years. Would like to get this taken care of, any ideas?

1 Answer

Ken, The 86 on the refrigerator side would indicate a issue with the refrigerator sensor and would need to replace the fan motor and the sensor.

Read More...

1 Answer

Robert, You will want to look for a possible issue with the defrost sensor on the unit. This will be the most likely cause for this issue.

Read More...
John for Model Number RF260BEAESR/AA

My French door Samsung refrigerator has been working for three years. Now it does not cool at all, and it gives the error code 84 E, which seems to be for "Locked Compressor". Also, in the Inverter PCB, the LED Blinking Frequency is 4 (blinks four times between pauses), which again seems to be "Locked Compressor". I found on line the service manual for this model and did some measurements. All three winding of the motor were equal, 12 ohm. Resistance windings-ground is indefinite. Disconnected three wire connector in Invertor PCB that powers the compressor. Still the error code 84 E, and four blinking of LED. Measured the AC voltages that enter the Invertor PCB and the Main PCB: It was 120 Volt. Measured the DC voltages that enter the Invertor PCB from the Main PCB in the 7 pin connector: Pin 5 and 6 are ground. Pin 1 to 5 -13.2 V, Pin 2 to 5 – 13.2 V, Pin 3 to 5 – 5 Volt. Fuse is good. Disconnected all connectors from all three PCBs. Removed Main PCB and Invertor PCB; no visual damage on both sides of each one. No current draw with all connector disconnected. Plugged the first connector into the AC Entry Power PCB (small PCB). The current drew from the outlet was 0.05 Amp. Plugged one by one the connectors in the Main PCB. The current did not change: 0.05 Amp. Plugged into the Inverter PCB the 7 pin connector that supplies DC power from the Main PCB. The current did not change: 0.05 Amp. Pugged the AC power input connector into the Inverter PCB (but not yet the three wire connector that powers the compressor). After a couple of seconds the relay (in the Main PCB) clicked, and current from the outlet increased up to 3 Amp for a couple of seconds then the relay clicked again, the current dropped at 0.05 A, LED began to flash with frequency of 4, and code 84 E appeared. Removed power, plugged the three wire connector that powers the motor of the compressor, and powered up again. Happened the same as above. The compressor did not work. Used a digital and then an analog meter, in AC and DC range, to measure voltage between 3 wires that power the motor of compressor, but there was no indication of voltage at all (during the time period of powering up, relay clicking, and error code flashing). The frequency between these 3 wires was variable at first seconds then stabilized at about 5 KHz. Replaced the Inverter PCB with a new one. The same situation, error code 84 E, LED flash frequency of 4. Why it shows error code “compressor locked” even though the motor of the compressor is disconnected? What can be the reason why the compressor is not working?

1 Answer

Hello John, The fault code description in the service manual is referring to a sealed system issue. When there is a sealed system restriction, too much pressure is built up on one side and it cannot bleed of to the other side inside the system, causing the compressor to lock, since it cannot build up any more pressure. This will most likely take a Freon authorized technician to diagnose and correct.

Read More...
Rosanne for Model Number RFG297ABWP/XAA

Had an error code reading evaporator fan. Replaced evaporator fan two times, still not working. So had repairman out and he said it was main board since no power to fan. New board put in and still getting error code to evaporator fan. repairman checked over again and said main board could be bad too. But that would be odd to give same error code again. Repairman said nothing else he could do, told me to buy new refigerator, samsung junk. The refigerator is cold but freezer section is not getting cold.Freezer food all melted and now empty. It is set for -8 in freezer and 38 in the Refigerator. Now it is blinking -8 on readout continuously overnight. The refigeraror is not even 7 years old yet. I can't afford $2000 for a new one. Help any idea what it is. Could it be a sensor or something?

1 Answer

Rosanne, It is possible that the sensor is bad but you can test it for 5K ohms at room temp of 77 degrees. If the resistance is not good then the sensor would need replaced. It is very possible that the control board is the issue if there is no power to the motor but could also be a loose connection so would want to check for that as well.

Read More...
Captain Chaos for Model Number RFG295AAWP

Freezer stopped working but frig is fine. When I disconnect the Ambient-Sensor/Ice Room-Sensor plug from the PCB Board, the freezer starts to cool (dropped from 70+ to around 40 so far. That would lead me to believe the Step-Motor Valve is working because it is definitely cooling the freezer. But clearly something is not working. When all connections are on the PCB Board, no errors show on the readout. When I pull the connector I get an 8d 89 which makes sense to me since the board recognizes the sensors are not being read. Thoughts? I'm going nuts here...thanks!

1 Answer

Hello Captain Chaos. This would point to a sealed system failure on the unit. You will need an HVAC tech to come out and repair the unit for you. Thanks.

Read More...
Mike for Model Number RF268ABRS/XAA-0000

My freezer slowly/intermittently was getting warmer over the course of a 5-6 months until it finally stopped freezing. The evaporator has no ice and the refrigerator is cooling perfectly. I have replaced two thermistors, one which sits next to the accumulator next to the evaporator in the freezer compartment and another that sits on the inside top of the freezer compartment housed in a plastic covering. I also replaced the PCB main board to no avail so I am running out of ideas. I tried forced and self diagnostics (start up) but can't seem to get any reading (maybe I am not doing the diagnostics correctly). I read somewhere it could be a step valve or a problem with the sealed system although I don't understand the latter if the fridge is working perfectly. Any help would be appreciated.

1 Answer

Mike, This issue would most likely be caused by a faulty stepping valve which would be part number DA97-07070B which is part of the sealed system and would need to have a service technician to install.

Read More...

1 Answer

Diego, You will want to test the sensors in this unit which at room temperature should read 5K ohms at room temperature. This will be the most likely cause for the unit to get too cold with the main board having been replaced.

Read More...

1 Answer

Hello Joe. As long as the door is open, there will be no voltage. The door has to be closed.

Read More...

1 Answer

Dave, This inverter board would control the compressor of the unit. If this board is burnt then it would be a faulty inverter board.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • Over 2.1 Million Parts In Stock Over 2.1 Million Parts In Stock
  • 2 Day Quick Delivery! 2 Day Quick Delivery!
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Google Trusted Store Google Trusted Store