This power control board is a genuine Samsung part, sold individually. This power control board is a replacement part for a refrigerator. The power control board is located in the back of the refrigerator. The purpose of a power control board is to maintain and manage the refrigerator's compressor. If a refrigerator is not maintaining its temperature properly, the power control board may need to be replaced. This type of board has an LED light that will signal if it is not functioning correctly. If this LED light is going off, the power control board should be removed and replaced with this genuine OEM replacement part. The repair or replacement process for a power control board is simple to perform and will require no specific tools. Make sure to wear gloves while performing this replacement for safety when dealing with electrical currents and potentially hazardous materials. This is an OEM part sourced directly from the manufacturer. This power control board is compatible with Samsung brand refrigerators.

More

Questions & Answers

For Samsung Power Control Board (Part Number: OEM14945724)

Bob for Model Number RFG298AARS

Hi, I have a Samsung model rfg298aars refrigerator that has quit cooling both in frig,and freezer. I had previously did some wiring in my house and had to shut the main power off and on numerous times the next day the frig. was not cooling. I had a repair man come check it out. The compressor was not getting any power he said.He then checked the pba sup panel and the fuse was burnt.He could not locate a new fuse (3amp al/250v} Are these fuses available or do I need a new board.Could the pba sub panel be the cause of the compressor not running. Any help will be appreciated, also approx how long would it take to get a new panel delivered to Redford,NY 12978 and if its not the panel can it be returned. Thank You

1 Answer

Bob, Yes, the sub pba could cause the compressor not to run. The fuse is not a separate part and you would need to replace the control board.

Read More...

1 Answer

Hello Sonny. If you can not set the temp, you need to unplug the unit for about 15 minutes to reset and if the issue continues, you will need to replace the board on the unit.

Read More...
Thanh for Model Number RS263TDWP

Hi, My refrigerator is not cold. I opened both fridge and freezer coil and see that the fridge coil is barely cold and not cold at all on the freezer coil. The compressor is running though. A technician checked it and said he wanted to replace both compressor and inverter board. He doesn't want just to replace the compressor which is under warranty. It seems strange that both can go bad at the same time. Is there a way for me to isolate the issue? Could I check the input and output on the inverter board to see if the problem is on the inverter board or the compressor? Could I also check the compressor input resistance to see if it is working properly? I have a voltmeter with frequency measurement. Thanks.

1 Answer

Hello Thanh. If the compressor is running, the board is good. It sounds like a sealed system issue.

Read More...
Mike L. for Model Number samsung refridgerator RF268ABBP

My refridgerator has been repaired by a service tech because of a leak in the coil. The leak was repaired and the pump replaced and the system was recharged. About a month after the repair the refridgerator went into a defrost cycle and the cycle extended until everything had melted in the freezer compartment. It then started cooling again and froze everything. I started by replacing the bimetal sensor on the cooling coil. This changed nothing. It cooled until the next defrost cycle and melted everything again. I then changed the large main circuit board. Again, this changed nothing. It cooled til the next defrost cycle and melted everything again. I then changed the smaller circuit board- part # DA41-00404E. This corrected the defrost cycle problem and the refridge worked as it was suppose to. One month later the defrost cycle malfunctioned again. I replaced the panel again and it worked for 3 weeks and then failed again. Can you give me some insites on where the problem might be and how to repair it?

1 Answer

Hello Mike, Based on the information provided, you may want to check your evaporator thermistors. If the thermistors DA32-00006S are causing the unit to stay in defrost then this will cause the unit to not operate. There is a thermistor in both upper and lower sections. You can check the resistance of the thermistors by filling a cup with ice water preferably crushed and add a teaspoon to make a slush. Mix thoroughly and allow to sit 2 to 3 minutes. This will give you a 32 degree reference. Put the thermistor into the mixture and allow to sit for 1 minute. Check the resistance which should be close to 13,300 ohms. Before reinstalling thermistor be sure to rinse off with fresh water. You can test this with a multi-meter TJMA-DMT3. Here is a link on how to use a multi-meter. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • Over 2.1 Million Parts In Stock Over 2.1 Million Parts In Stock
  • 2 Day Quick Delivery! 2 Day Quick Delivery!
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Google Trusted Store Google Trusted Store