This power control board is a genuine Samsung part, sold individually. This power control board is a replacement part for a refrigerator. The power control board is located in the back of the refrigerator. The purpose of a power control board is to maintain and manage the refrigerator's compressor. If a refrigerator is not maintaining its temperature properly, the power control board may need to be replaced. This type of board has an LED light that will signal if it is not functioning correctly. If this LED light is going off, the power control board should be removed and replaced with this genuine OEM replacement part. The repair or replacement process for a power control board is simple to perform and will require no specific tools. Make sure to wear gloves while performing this replacement for safety when dealing with electrical currents and potentially hazardous materials. This is an OEM part sourced directly from the manufacturer. This power control board is compatible with Samsung brand refrigerators.

More

Questions & Answers

For Samsung Power Control Board (Part Number: OEM14945724)

1 Answer

Curtis, You will want to check to make sure that the connections on the inverter board are good and at the compressor. If the wiring is ok then replace the inverter board and if the issue continues then the compressor would need to be replaced.

Read More...
Maggie for Model Number RF28HFEDTSR/AA

Problem: Noticed interior temp seemed warm, checked with 2 independent thermometers inside cabinet. Both were reading ~ 50 Deg. inside refrig. Panel display was set and reading 40 deg. • Removed inside refrig. evap. panel to see if evap. coils were iced over- o Minimal to no-ice build-up on evaporator coils. o There was ice at top above the evap. coils around temp sensor and copper tubes. ? Defrosted all the ice, reassembled and restarted the fridge. o The panel temp was set to 38 waited for interior to cool down and reloaded food. o Next morning interior temp was 43 deg. • Freeze is maintaining 0 degrees. • Both ice makers are on and making ice. • Using "Force mode" function: o "FF"- Compressor sounds to be working, you can hear it start and run. ? If Refrigerator is put into "Force Mode" the temperature can go to 32 or colder. o "rd"- Refrigerator Defrost- appears to be working audible/hear it. Plastic popping sound. • Observation- Door temp. display appears lower 38 Deg. vs interior temp. 46 deg. or higher. • Inverter board LED solid when compressor is running/off when compressor is not running

1 Answer

Maggie, if the thermistors inside of the refrigerator are measuring in resistance the correct temperature of the cabin (as taken by a thermometer) then the issue would be with the main control board. For the most accurate information regarding the main control board, the REV number would be needed.

Read More...

1 Answer

James, we wouldn't expect a new inverter board to be defective at this point. Since the compressor checked OK you want to check the inverter PCB and compressor relay connectors. If the connectors are OK, replace the inverter board, if no change replace the compressor. On the inverter board, check the CN04 connector wires for 13 VDC black to gray wires, and 5VDC across brown to gray wires from the main PCBoard, if you have the voltage recheck the compressor windings and replace the inverter board. if the voltage is low or no voltage, replace the main PC board. for

Read More...

1 Answer

James, With the unit running too cold then this would most likely be an issue with the main control board.

Read More...

1 Answer

Andy, It sounds like the inverter board has failed on the unit and would need to be replaced. Check connections of the wiring to the compressor first and if this checks ok then replace the inverter board.

Read More...

1 Answer

Hello Kim, the main control board has detected a problem with the compressor's inverter board sending power to the compressor. The inverter board is part DA41-00614F.

Read More...
Lionel for Model Number RFG297AARS

FREEZER AND FRIDGE WERE WERE NOT KEEPING COOL OR FREEZING. DID A RESET BY PUSHING POWER FREEZE AND POWER COOL AT THE SAME TIME. THAT SEEM TO WORK TILL THE NEXT DAY. I TRIED IT AGAIN AND ALSO UNPLUGED IT FOR TEN MINUTES ,DIDN'T SEEM TO DO ANYTHING . I TOOK OFF THE BACK LOWER COVER .THE FAN AND COMPRESSOR WERE NOT RUNNIG. TOOK COVER OFF OF CONTROL BOARDS,THE RED LIGHT ON INVERTER BOARD IS NOT ON. UNPLUGGGED AND REPLUGGED, RED LIGHT BLINKED TWICE THEN STAYED OFF . COULD HERE A CLIK ON BIGGER BOARD. COMPRESSOR AND FAN STILL DIDN'T START . DID ANOTHER RESET LEFT IT FOR TEN MINUTES IT IS RUNNIG WITH RED LIGHT ON .ITHAS BEEN RUNNIG 40 MIN. ONLY AT 7C FIRDGE IS AT 4C

1 Answer

Hello Lionel, the 2 blinks is a code for an internal failure in the compressor inverter (driver) board ,repair will be replacing the inverter board part DA41-00614F.

Read More...

1 Answer

Hello Dan, since the self-test showed no fault codes, meaning control board operation is not being affected by something external to the board then the next step is to replace the main control board itself. DA41-00538A

Read More...
Michael for Model Number RF268ABRS/XAA-0000

The compressor will not come on to cool the freezer or the refrigerator. The fan runs immediately and stays on when plugged in. I replaced the inverter board and the overload protector and there has not been a change. The red LED light on the inverter board is on and is NOT blinking. I hear the clicking to turn on the compressor every few minutes but nothing seems to change. Any ideas on what might be the problem? Perhaps the compressor is bad?

1 Answer

Michael, it is very possible that the compressor has failed. The windings would need to be tested (with the refrigerator unplugged) by testing from each pin to the other on the compressor. The windings should measure equally when each set is tested. If not, then the compressor has failed.

Read More...

1 Answer

Hello Ron, the compressor inverter board is detecting a low voltage condition and will not power up the compressor, replace the inverter board part DA41-00614F.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • Over 2.1 Million Parts In Stock Over 2.1 Million Parts In Stock
  • 2 Day Quick Delivery! 2 Day Quick Delivery!
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Google Trusted Store Google Trusted Store