Skip to Content
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Trusted Since 1999 Trusted Since 1999
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google

Customer Questions and Answers for Dryer Thermistor Temperature Sensor by Samsung

Best Seller
Manufacturer Part
4.89 (64)
By: Samsung
Part Number: OEM12605157
Manufacturer Part Number: DC32-00007A

Dryer not heating or drying inconsistently? A faulty thermistor causes temperature control issues. Direct repair—moderate difficulty, 30-45 minutes.

More
$30.54

IN STOCK
Ships Today Guaranteed
Add to Cart

Questions & Answers

For Samsung Dryer Thermistor Temperature Sensor (Part Number: OEM12605157)

Brittany B for Model Number samsung DV218AGW/XAA

After reading online that an error code to "to" may mean that the thermistor needs replaced, I was heading down that path of ordering one. However, now I'm reading that a lot of those weren't getting heat. Mine will start the dry cycle and get hot but then shuts off after about 30 seconds to a minute. Could this still be the thermistor or not if it's getting hot? I've tried unplugging for a while to "reset" and I have vacuumed out the lint area and the back. Thank you!

1 Answer

Brittany,

With the units heat shutting off within 30 seconds, check the venting to make sure that the venting is clear. If this venting is clear then he gas coils would be the most likely cause for this issue.

Read More...
Jack J. for Model Number DV50F9A6EVW/A2

My dryer keeps blowing the thermal cut off fuse next to the heating element. I have replaced the element and fuse, cleaned the vent and blower out. That lasted about three months then it blew again. Checked the element it if fine ohms out good checked vent and it was good. That lasted one night and it blew again. I tested the thermistor and the ohm reading is within specs. Both relays on the control board show open. I am going to try a new thermistor next. Any ideas why this would be happening?

1 Answer

Hello Jack,
You should check the dryers' exhaust duct for a full 4-inch diameter all the way to outside atmosphere. The only thing that can open the thermal fuse is excessive temperature. If there is a restriction in the ducting that holds the exhaust in the dryer, the thermal fuse is opened to prevent potential fire hazards.

Read More...

1 Answer

Jim, if the dryer is shutting off as if it has finished a cycle and indicates the cycle is done, the sensor bars likely would need to be thoroughly cleaned. If the console is completely shutting down, the failure would be in one of the two controls, either the user control DC92-01647A or the main control DC92-01606D. As one has been replaced, the failure would likely be in the other if proper voltage is reaching the dryer.

Read More...

1 Answer

Jim, it would be recommended that the door is inspected to identify if it moves enough to temporarily stop pressing the door switch DC64-00828B as this can cause the dryer to stop. If the door does not have enough movement, and the door switch maintains being pressed, it would be likely that the main control DC92-01606D has failed.

Read More...
Stephen for Model Number DV50V9A7EVW/A2

I've changed the Moisture Sensors, the Dryer Thermistor, the Thermal Fuse, and the Thermostat. It still gets stuck on 1min and doesn't turn off. Now, if the dryer sits for a while, completely cooled down, it will go through all the steps and shut off. If a second load needs to be done right after or shortly after, it gets stuck on 1min. There is heat, clothes/blankets are hot, so lack of heat isn't the problem. Running the SmartCare diagnostic, it doesn't report a problem. This all started when I cleared out the dryer vent and dryer exhaust area because it gave an "HE" signal. What else could be causing this issue? My only thought at this point is the control panel.

1 Answer

Steven,

It would be recommended to check to make sure that there are no wires that are loose or disconnected, which sounds most likely. If there are no wires disconnected then it would be an issue with a control board.

Read More...

1 Answer

Rich, the main control can be tested for voltage output using the blue wire at relay 6 and the brown wire at relay 5 to test for a voltage reading while the dryer is running. If there is a voltage reading, the main control has failed. If there is 0 volts reading, then with the dryer power cord unplugged, the thermistor DC32-00007A would indeed be tested for resistance and it should measure around 10KO at room temperature. The thermal fuse DC47-00015A and hi-limit thermostat DC47-00018A would be tested for continuity. The heating element DC97-14486A should measure 10O.

Read More...
Rich Clark for Model Number DV350AEG/XAC04

Problem - Dryer runs but no heat. I have pulled the heater housing and checked the heater coil, no breaks and resistance reads 9.6-9.7 ohms. Hi Limit T'stat has continuity and reads 0.0-0.1 ohms, Thermal Cutoff has continuity and reads 0.3-0.4 ohms. On the wiring diagram on the dryer frame both the Hi Limit and the Thermal Cut off are on the line to the heater and the red wire from the heater goes to the motor. I read in some of the other Q&A about a thermistor. I also see a Thermistor on the wiring diagram, but it is not connected to any of the 3 heating related components. Where do I find the thermistor in the dryer? Can I test for resistance and continuity and only at the main control panel? What are the numbers for resistance and continuity? Thanks a lot for being available to answer. Rich

1 Answer

The thermistor DC32-00007A is located on the blower wheel housing. No continuity check. Resistance check where it is mounted should measure about 10k at 77 degrees F.

Read More...
Joe for Model Number DV431AEP/XAC

My Drier intermittently has no heat? The thermal cut off fuse (DC47-00015A) keeps tripping, ie. going open circuit. It's intermittent, it may run for a month, a week, or few days before tripping. 1. I have cleaned out the whole machine and external ducts. 2. I have checked the heating element it reads 10 ohms, also checked to ground no short, visually inspected all okay. 3. Checked lower limit thermal fuse = 0 ohms 4. Checked thermistor at 70 degrees approx 10.5 K ohms, also warmed it up and cooled it down, with air and the resistance changes up or down accordingly. 5. Checked the connections of all the above all okay. 6. Checked heater relay switch on the main PCB with power off, reads open circuit. 7. Checked the main power into the rear of the machine 242 VAC, and connections are good. Any suggestions would be greatly appreciated, thanks Joe

1 Answer

Joe, based on the information provided, it sounds like the main control DC92-00669J is not registering the heat input from the thermistor properly which can cause overheating. Unfortunately, this part has been discontinued by the manufacturer and is no longer available.

Read More...

1 Answer

David,
Check the thermistor for the resistance of 10K at room temp give or take a little. All the other thermostats are just a continuity test. Since it does heat it could be the high limit trips to soon. We will send you a page to properly test the thermostats and the element itself. Dont forget the control reads the thermistor so if all checks good it could be that also.

Read More...
Bill for Model Number DV42H5000EW

I have a Samsung DV42H5000ew and the thermal fuse (DC96-00887A) on the heating element housing has blown twice, most recently one a day after it was replaced. After it blew the first time, I replaced the high limit thermostat (DC47-00018A) as well as the heating element (DC47-00019A). Since it has blown again, I have tested the thermistor (DC32-00007A) and got 9.16 ohms. My understanding that 10-11 ohms is normal - is my reading too low to the point that the thermistor is not regulating heat properly? I tested the thermal fuse (DC47-00016A) on the blower (next to the thermistor) and it has continuity. The vent and blower are extremely clean, figured I'd find some lint but did not. I have great air flow at the vent cap. I did discover that the dryer cord was incorrectly wired so far as the ground jump wire from the dryer was wired to the ground of the cord instead of the neutral terminal. I have corrected this mis-wire - is it possible that, after 5 years of normal operation, this wiring issue caused problems that led to the thermal fuse on the heating element housing blowing? At this point, I can't think of anything else that could be causing the dryer to overheat and blow the fuse. Any suggestions on what else to check?

1 Answer

Hello Bill,
the thermal fuse mounted on the side of the heater housing will only open due to high heat. The question then becomes what is causing the overheat, the most likely is a grounded heater element which can be checked with a multimeter or visually and also if there are signs of arc marks inside the housing, the other possibility is a poor terminal to terminal connection on the thermal fuse terminals and the wire harness terminals, a poor connection will cause the terminals to heat and give a false trip.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google