Rob July 04, 2020 for Model Number DV431AGW/XAA 01 The dryer operates and heats, but will not end an automatic cycle on its own. The time dry functions don’t count down either - the dryer heats up and works fine, but the timer does not count down. Any suggestions? Thanks in advance!
1 Answer Rob, With the timer not counting down at all then this would be an issue with the main control board DC92-00322F. Read More...
Andrew June 27, 2020 for Model Number dv42h5000ew/a3 I am getting an HE error code for a dv42h5000ew/a3 Samsung dryer. The dryer runs for approx 3 minutes then shuts down giving the HE code. It is *VERY* hot and a believe the shutdown is an overheat protection. Is this caused by a bad thermistor, bad thermometer, or bad control board?
1 Answer Andrew, This issue sounds like a control board that has a stuck relay on it and would need to replace the control board. Read More...
Justin Kunak June 11, 2020 for Model Number DVE50M7450W/A3 I have a Samsung dryer model number DVE50M7450W/A3 and it is not drying my clothes completely,especially my towels.I have tried different drying settings to put it on and it still gives me the same result.I have checked the heating element and it is working properly and I have cleaned lint out of the dryer and made sure vent discharge outside is clean.I have been looking and reading on your site and it has been saying to check different sensors on unit.Could your possibly give me a list of the sensors that would need to be checked and there part numbers.Thanks very much for your time.
1 Answer Justin,It is possible that the exhaust is clogged somewhere between where it goes in your wall and exits the house. Remove the duct at the back of the dryer and dry one load. If your clothes dry in one load clean the duct from inside the laundry room all the way out of your house. Read More...
Gary June 01, 2020 for Model Number DV45H7000EW/A2-02 No heat and dryer will not turn off unless you open the door
1 Answer Gary, the dryer may be in a continuous run mode in regards to the constant running. This can be checked by pressing and holding the mixed load bell and dry level buttons while the unit power is on. Once 8 seconds have passed, if the display starts showing "CC" and then the remaining time, the continuous run was not activated and the same process would need to be performed to exit continuous run. At this point, the terminal block would need to be tested for 240VAC from the red wire to the black wire with a meter. If there is not 240VAC, this can impact the heating ability. If there is, the unit would need to be unplugged and the main control tested at the motor relay (relay 2P) from terminal to terminal for continuity. If there is continuity, the main control DC92-01626B has failed as the relay is stuck closed. The last step would be to test the heating element DC47-00019A for resistance, the thermal cut-off DC96-00887C for continuity, and the hi-limit thermostat DC47-00018A for continuity. The heating element should measure 10O and the thermal cut-off and hi-limit thermostat should measure continuity. If the heating components test good, the main control heating relay has failed in the open position. If there are no grounded wires going to the motor, the motor relay is sticking closed and the main control would need to be replaced. However, the motor DC31-00055G would need to be tested from terminal 6 to terminal 5 for continuity. If there is continuity, the centrifugal switch is sticking and this could be the potential cause for both issues. Read More...
Keith May 08, 2020 for Model Number DV48H7400GW/A2 At first, dryer would not stop tumbling unless plug pulled. Heat would turn off though. Display would show the moving [ { } ] continuous running icon or would be completely blacked out. Replaced DC92-01626A main board, heat seems to work normally and it shuts off with power button or opening the door, but display is complete gobbly-gook, multiple dial lights on, multiple mode lights as well. Replaced DC92-01624F board behind user interface control panel, no help. We can get it to mostly heat and tumble as long as we get the t-shirt drying symbol on, but there is no rhyme or reason, that I can tell, to make any sense of the display and cycle settings. PLEASE ADVISE
1 Answer Keith, based on the information provided, it would be recommended that the wire connections are inspected to ensure there is not a loose connection. If there are no loose connections, then it is likely that the main control DC92-01626A is miscommunicating with the user control and would need to be replaced. Read More...
Doug April 27, 2020 for Model Number Samsung dv350aeg/xac How do I check if the relay on the control board isn't closed causing the Thermal Fuse to blow?
1 Answer Doug, If the relay on the control board is stuck closed then you could do a continuity test on it with the control board disconnected and power turned off to the unit. If there is continuity then it is a faulty relay. Read More...
Buddy March 27, 2020 for Model Number Samsung Dryer DV42H5000EW/A3 The dryer runs, but has no heat. Also, the dryer turns off prematurely. For example, if I use a manual setting of 60 minutes on high heat, the dryer will run (with no heat at all) and will turn off after some time (way before 60 minutes). The vents are clean. The vent blockage test was not working, but I opened it up and confirmed no blockage. The lent trap is also clean. Thermistor has no continuity. Thermostat and thermal fuse both have continuity. Will replacing the thermistor fix the problem, or does something else need to be fixed also? Thanks!
1 Answer Buddy, The thermistor would be checked for resistance, not for continuity. The resistance of the thermistor will be 10K at 77 degrees. If the thermistor checks ok then the control board or wiring will be the issue. Read More...
Ernie February 09, 2020 for Model Number DV405ETPASU/AA-0001 Hello, I have replaced the thermostat a couple of times, and the dryer element on my dryer. After replacing the the thermostat for the first time, along with the heating element, I got some heat, but not enough, after about a load, the dryer went cold (cold air only). I replaced the blown thermostat again, but I got cold air only once again. I checked the Thermistor, and get a 0. Would a bad Thermistor cause the thermostat to keep dying, or the dryer not to blow hot air. Is there anything else that I should try out. I have also confirmed that the relay switch is working. Thanks for your help.
1 Answer Ernie, if the thermistor DC32-00007A is reading 0O then it has certainly failed and would cause the element to overheat, causing it to blow the thermostat DC47-00018A or thermal cutoff DC96-00887C. Read More...
Jessaca Blanco December 21, 2019 for Model Number Samsung-steam moisture sensor (not sure model but can get later) Hello, your the fact that you help so many people, is absolutely amazing. Thank you. My dryer (like some many others) was at first overheating. The clothes were so hot that they were burning my hands to pull them out. Eventually, the dryer stopped heating altogether and was giving me the HE code. The dryer still comes on but it doesn’t heat. This is an electric dryer. I have checked the vents but am lost as to what to do next. I don’t have an electrical tester. Would you be able to tell me what exactly I need to purchase to check for the problem? Thank you so very much! Again, this is so amazing that you offer so many help. This is very stressful! I have teenagers! Haha
1 Answer Jessaca, It would be hard to determine exactly what is wrong with the unit without doing the necessary testing. Since the unit was getting too hot prior to not heating at all then it sounds likely that you have at least the high limit thermostat and the thermal fuse on the heater housing that is faulty. Read More...
Pgd November 18, 2019 for Model Number DV350AEW/XAA-0000 I did note the position of the colored connecting wires on the thermistor, however, I did not take note of the orientation of the thermistor when removing it. I am assuming this matters since we were told to note the position of the colored wires before removing. How can I know the correct position of the thermistor when replacing it and reconnecting the plug?
1 Answer PGD, This is a 2 wire connection in which it will not make a difference which wire will go to which terminal. Read More...