Traci for Model Number DV350AER/XAA-0000

My Samsung dryer had stopped heating. It would run but without heat. I found that the heating element had a crack in it, I replaced that, and the thermal fuse as I found that had also blown. After the initial test, the thermal fuse had blown again. After more research, I replaced the Thermistor, and the thermal fuse again. The dryer starts to heat, smells hot, then the heat stops, and blows the fuse. It doesn't appear that the heating element is shorting, or touching the metal case. The blower is producing air, all the vents are clean of lint, The thermostat has continuity, so I assumed that was functioning. Could that need replacement? I can't seem to find out what else I can try. There are no errors on the panel, it runs fine, just no heat.

1 Answer

Traci,

You will want to check to make sure that the relay on the control board is not stuck closed which will cause the thermal fuse to blow.

Read More...

1 Answer

John,

If the dryer runs for 20 seconds and then shuts down then the motor sounds likely that it would be overheating and you would want to see if there is anything that is causing a bind on the motor and causing it to shut down.

Read More...

1 Answer

William, based on the information provided, as the timer will count down to end of cycle but the motor will not stop rotating, the most likely cause is the motor relay getting stuck closed. To correct this issue, the main control would be the part to change out. For the correct main control, the full model number and REV number would be necessary to ensure the correct part is notated.

Read More...
Reymond for Model Number DV50F9A8EVP/AC

Hi I am encouraged seeing your forum here. I am in trouble with this Samsung dryer. Dryer overheats and HE code appears. I thought heater assembly. so replaced whole assembly with new with thermistor and thermostat. Vent is clean. Yet the same, overheating and HE code. T=Dryer heats up in any position of the switch means even in Air Fluff or any other position. What could be the reason? I was going through the wiring and it seems the heating element has thermistor & thermostat in series with power circuit. So they should control the heat. Am I right or circuit board problem? Will appreciate your help.Thank you- Rey

1 Answer

Reymond, if the heating element is operating during air fluff, then the heater relay would be stuck in the closed position on the main control. This would indicate a control failure and the REV number for your model would be necessary to ensure the correct part can be located.

Read More...

1 Answer

Attila,
Usually, when you have long dry times it is not the result of the heater but a clog in the venting system. Unhook your vent in the back and make sure on a heat setting there is air blowing out and see if it will dry completely in one cycle. If it does then you need the vent cleaned from the wall behind the dryer to the outside.

Read More...
Steve for Model Number DV218AEW/XAA - Samsung ELECTRIC Dryer - No Gas Connection

I was getting 2 errors. HE and TS HE was more common but the TS started showing up as I was troubleshooting. I replaced both the Thermistor and the Thermal Switch that is next to it. TS error seems to be ok now, but the unit still gives me the HE Error after about 20 seconds of operation Regardless of setting (sensor or timed dry) or temperature setting. low, medium, high, extra high) I cannot detect any heat in the drum, but it really is not running very long before it shuts off so probably not a great measure. I completely cleaned the lint trap and all related parts (blower motor too) The venting from the blower motor all the way to the outside of the house is clear. Using a multimeter, I have verified 244V AC at the outlet. 120 from each hot side and 244 from both hots. Where do I go from here?

1 Answer

Steve, based on the information provided, you may want to inspect the wiring for the thermistor going to the control for any breaks or bare wires. If the wiring checks good, then the issue would be with the main control board DC92-00160A.

Read More...

1 Answer

Big Bob,

This error code would indicate a thermistor that is open and would need to replace the thermistor on the unit.

Read More...

1 Answer

Mike, You may want to check the incoming voltage for 240VAC at the terminal block using a multimeter TJMA-DMT3. If there is not 240VAC, then you will want to test the outlet as this will indicate if it is a power cord issue or outlet issue. From there, with the power cord disconnected, you may want to test the heating element DC47-00019A for 10 ohms resistance. If it reads 10 ohms, it is good. From there you will want to test the thermostat DC47-00018A and thermal fuse DC96-00887C on the heater assembly for continuity. If there is no continuity, the failed part would need to be replaced. If all of this checks good, then you will want to do a voltage check at the heater relay RY6 for 120VAC at each terminal while the dryer is in operation. If there is 120VAC going in but not leaving the relay, then the main control DC92-00669Y would be the cause.

Read More...

1 Answer

Devon ,if the dryer stops on its own then restarts on its own that sounds like the drive motor is overheating,Since this is an electric dryer check the incoming voltage using a multimeter at the dryer electrical terminal L1 Black to Neutral White with dryer off then again running.Voltage should be about 120v, if it is off either higher or lower by more then 10% that could cause overheating of motor. If voltage is correct check if the dryer drum is binding in any way causing a heavy load on motor.Lastly check the heating element for signs it is grounding to chassis.

Read More...

1 Answer

Morgan,

With the motor not starting you will want to check the belt switch located by the motor to make sure that it is good for continuity. Check the door switch to ensure that it is good for continuity, check the thermal cut off to make sure that it is good for continuity. If these check ok then check to see if there is 120 vac getting to the motor when the unit start button is pushed and if there is no power then the control board is faulty and if there is power then the motor would be the issue.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google