Tara February 15, 2016 for Model Number WHIRLPOOL FRIDGE: GI5FSAXVY00 Lights are on touch pad not working at all fridge not cooling but its running.
1 Answer Tara, With the touchpad not responding then you will first want to make sure that the child lock is not on. If it is not then it sounds like it would be a keypad issue. If the units compressor is running then you will want to pull the cover in the rear of the freezer compartment and check the frost pattern of the evaporator coils. If it is impacted with ice then there would be a defrost issue and need to test the heater and thermostat to make sure they have continuity.If they do not have continuity they would need replaced. If there is no ice on the coils or very little at the top and the compressor is running then this would be a sealed system issue and would need a refrigeration service tech. Read More...
Fmoulton February 05, 2016 for Model Number maytag w10310240 hv board How do I reprogram hv board maytag w10310240?
1 Answer Hello Fmoulton. You will need to program in the "personality" code into the new control board for the refrigerator to operate. You should find the tech data sheet attached to the bottom of the refrigerator, behind the lower kickplate grill, in a plastic bag, The code is listed on the model/serial tag inside the refrigerator. In the mean time " Programming Mode: NOTE: The Program Code is located on the Serial Plate on this unit after the word Code. 1. Press and hold the Door Alarm Keypad 2. Press and hold Freezer Temperature Down Keypad . 3. Release the Door Alarm Keypad and wait 3 seconds. 4. The control will display PE to indicate the programming mode. 5. Entry is confirmed by pressing the Freezer Temperature Down Keypad once more. 6. The control will display the current Program CODE. This value should be validated with the Program CODE printed on the unit serial plate. NOTE: If the Program CODE is correct, the Programming Mode is exited by pressing Door Alarm Keypad for 3 seconds. 7. Press the Refrigerator Temperature Up Keypad or Refrigerator Down Keypad to change the digit value with each key press. 8. The decimal point indicates the selected digit. Press the Freezer Temperature Up Keypad to select the next digit. 9. Once the desired Program CODE is entered, press and hold the Freezer Temperature Down Keypad until the Program CODE begins flashing indicating it has been saved. NOTE: If you attempt to enter an invalid Program CODE the control will not save the new code, but will beep. (The unit will NOT run with a Program CODE of 0000).Once the Program CODE has been saved the Programming Mode is exited by pressing any key. If the new code is incorrect this process should be repeated." Read More...
Alvaro January 29, 2016 for Model Number KFIS25XVMS2 Hello, Ordered a new HV board to replace one that went bad during a storm. After installing new one, I only get the PEO 000 message on the display. Used the instructions to program it based on the tech sheet but they don't work. Can never get it to the PE mode, only gets there is I press and hold the UR button but gets back to the other one a send after. Is there another sequence I can try?? The original board was part # W10213583 and the new board is the W10310240 which is supposed to be compatible. Does the new board require a diff sequence to program it? Thanks
1 Answer Alvaro, There is no other sequence to enter into the programming mode other than what is on the tech sheet that comes with your unit. Read More...
Wayne January 27, 2016 for Model Number MFI2569VEM Display is flashing and ice dispenser flap is opening and closing. My research so far says the problem is likely the HV board
Rene December 19, 2015 for Model Number GI5FSAXVY00 I replaced the main circuit board and not the display is showing P0000. I tried pushing the buttons in the sequence suggested on one of your answers, but it does not respond at all. Holding the alarm button down for 4 seconds does not work either. I am out of ideas. Help
1 Answer Rene, You will need to program in the "personality" code into the new control board for the refrigerator to operate. You should find the tech data sheet attached to the bottom of the refrigerator, behind the lower kickplate grill, in a plastic bag, The code is listed on the model/serial tag inside the refrigerator. In the mean time " Programming Mode:NOTE: The Program Code is located on the Serial Plate on this unit after the word Code. 1. Press and hold the Door Alarm Keypad 2. Press and hold Freezer Temperature Down Keypad . 3. Release the Door Alarm Keypad and wait 3 seconds. 4. The control will display PE to indicate the programming mode. 5. Entry is confirmed by pressing the Freezer Temperature Down Keypad once more. 6. The control will display the current Program CODE. This value should be validated with the Program CODE printed onthe unit serial plate. NOTE: If the Program CODE is correct, the Programming Mode is exited by pressing Door Alarm Keypad for 3 seconds.7. Press the Refrigerator Temperature Up Keypad or Refrigerator Down Keypad to change the digit value with each key press. 8. The decimal point indicates the selected digit. Press the Freezer Temperature Up Keypad to select the next digit. 9. Once the desired Program CODE is entered, press and hold the Freezer Temperature Down Keypad until theProgram CODE begins flashing indicating it has been saved.NOTE: If you attempt to enter an invalid Program CODE the control will not save the new code, but will beep. (The unit will NOT run with a Program CODE of 0000).Once the Program CODE has been saved the Programming Mode is exited by pressing any key. If the new code is incorrect this process should be repeated." Read More...
1 Answer Hello John. You will need to order and replace the HV board W10890094 on the unit. Read More...
Jade L December 13, 2015 for Model Number GI5FSAXVY01 The control panel on my refrigerator appears to be malfunctioning. All of the buttons work with the exception of the button for the ice maker. Whenever I press it, the three lights on the left of the panel for power, filter reset and lockout light up, but nothing else happens. I've tried unplugging it, resetting the panel, making sure the code is right, but nothing happens. The ice maker continues to make ice and everything else works. It just won't switch over to dispense ice. Any ideas on what I could do?
1 Answer Jade, The Hi Voltage control board is a good possibility but with no other problems and based on your description we would think you should start at the dispenser assembly and replace the W10740218 dispenser electronic control. You most likely have a short circuit in the keypad(s) and/or control board. Read More...
Mike November 02, 2015 for Model Number Maytag mfi2269VEM fridge Came home to a puddle of water outside our fridge dripping from the water/ice dispenser along with no display or any lights on the dispenser. Fridge interior lights work but there is no cooling, no noise of any fan, compressor, ect. Does this sound like one of the control boards? Is it common for the main board or dispenser board to go bad? The Fridge is only 3 years old. Thanks, -Mike
1 Answer Mike, With the unit not cooling and water dripping from the dispenser, this issue sounds like it would be a faulty main control board that has failed. Read More...
Alex September 23, 2015 for Model Number MFI2569VEM2 The main control board was just replaced on Maytag fridge model: MFI2569VEM2. All I get is a PE0000 flashing on the display. The only thing I can get is H2O when I push refer temp up and ICE when I push refer temp down. The rest of the buttons don't work on control panel. It's not letting me to program code. Do you know what is the issue? Thank you!
1 Answer Hello Alex. Some of these are very hard to program. You will need to keep trying it until the program takes. I have had to do it several times before I was successful. Read More...
Marv September 22, 2015 for Model Number MFI2266AEQ Periodically it "beeps" (every 10 minutes).I've shut all of the alarms off including "SAB" and "cooling shut off". Have even left fridge unplugged for 3 minutes to "reset". No obvious problems with any of the functions or temperatures. I have checked and rearranged the items inside to ensure airflow isn't blocked. Then the "beep" has quit —once last year and once this year. Currently it is 'beeping". I'm thinking it may be a real alarm but I find no reference to any alarms but door & temperature (both are working and are not this). I'm not into "easter-egging" a fix. Your thoughts would be appreciated.
1 Answer Hello Marv. If there are no alarms or errors, you will need to replace the LV board 67006294 to repair the beeping error. Read More...