1 Answer Hello Frank, This board may not need to be programmed. If you could please post a new question with the model number from the units' I.D. tag we can pull the tech sheet and advise you on any programming that may be necessary. Thank you for your patience and understanding in this matter. Read More...
1 Answer Hello Charlie. No, you have to replace the main board on the unit if it is bad. Read More...
Gary August 08, 2015 for Model Number MFI2569VEM2 The dispensing controls do not work when the compressor is running. The lights remain on but no response when buttons are depressed. When the compressor stops running the dispenser controls work fine. I have replaced the dispenser control board. Do you think there is something wrong with the Hv Board?
Charlie July 31, 2015 for Model Number gi5fvaxvb02 Will control board number 12920721 work on my refrigerator?
Phil June 09, 2015 for Model Number AFI2538AES12 My light on the control panel periodically flashes and the ice flapper keeps opening and closing. Was advised the High Voltage board needs replaced. Is this difficult to change?
1 Answer Hello Phil, You will need to replace the high voltage board WPW10310240 and it is not a difficult replacement. Be sure to unplug the machine before beginning this repair. Read More...
Suzie April 01, 2015 for Model Number MV 12569VEMO The flapp on the ice and water despenser keeps flapping continuosly. I replaced the front and back circuit boards. The front panel keeps showing PEO OOO and the fridge still doesnt work. Is there a way to programme it? Would certainly appreciate any help I can get from you.
1 Answer Hello Suzie. Programming Mode:NOTE: The Program Code is located on the Serial Plate on this unit after the word Code.1. Press and hold the Door Alarm Keypad .2. Press and hold Freezer Temperature Down Keypad within 3 seconds .3. Release the Door Alarm Keypad and wait 3 seconds.4. The control will display PE to indicate the programming mode.5. Entry is confirmed by pressing the Freezer Temperature Down Keypad once more.6. The control will display the current Program CODE. This value should be validated with theProgram CODE printed on the unit serial plate.NOTE: If the Program CODE is correct, the Programming Mode is exited by pressing Door AlarmKeypad for 3 seconds.7. Press the Refrigerator Temperature Up Keypad or Refrigerator Down Keypad tochange the digit value with each key press.8. The decimal point indicates the selected digit. Press the Freezer Temperature Up Keypad toselect the next digit.9. Once the desired Program CODE is entered, press and hold the Freezer Temperature Down Keypaduntil the Program CODE begins flashing indicating it has been saved.NOTE: If you attempt to enter an invalid Program CODE the control will not save the new code, but willbeep. (The unit will NOT run with a Program CODE of 0000).Once the Program CODE has beensaved the Programming Mode is exited by pressing any key. If the new code is incorrect thisprocess should be repeated.The Programming mode can be exited at any time by pressing Door Alarm key for 3 seconds orwill exit if unattended for four minutes. Read More...
Robert March 13, 2015 for Model Number MFI2266AEB I just recently replaced this part Rail-Mullion Part Number: AP4299816, but now the controls on the door do nothing but beep when you push the buttons. The ice maker still makes ice but the dispenser is not working. The same with the water dispenser. Do I need to replace this part Board-Hv Control AP4568436 to fix this problem? Thank You
1 Answer Hello Robert, This sounds like a possible power supply issue on the main board WP71001680. Read More...
Rodney March 12, 2015 My model Maytag 7405MFE ice maker has quit making ice or makes 1 bin and stops. Everything else is working. Is it for sure the HV board.
1 Answer Hello Rodney. You need to check and make sure the temp is 0 to 5°. If not, that is the issue. If the temp is correct, then it sounds like the icemaker may be bad and need to be replaced. Read More...
Don March 04, 2015 for Model Number MFI2269VEM11 The board was just replaced. All I get is a PE0000 flashing on the display. The only thing I can get is H2O when I push refer temp up and ICE when I push refer temp down.
1 Answer Hello Don. It needs to be programmed. Programming Mode:NOTE: The Program Code is located on the Serial Plate on this unit after the word Code.1. Press and hold the Door Alarm Keypad.2. Press and hold Freezer Temperature DOWN /- Keypad within 3 seconds.3. Release the Door Alarm Keypad and wait 3 seconds.4. The control will display PE to indicate the programming mode.5. Entry is confirmed by pressing the Freezer Temperature DOWN /- Keypad once more.6. The control will display the current Program CODE. This value should be validated with theProgram CODE printed on the unit serial plate.NOTE: If the Program CODE is correct, the Programming Mode is exited by pressing Door Alarm Keypad for 3 seconds.7. Press the Refrigerator Temperature UP /+ Keypad or Refrigerator Temperature DOWN /- Keypad to change the digit value with each key press.8. The decimal point indicates the selected digit. Press the Freezer Temperature UP /+ Keypad to select the next digit.9. Once the desired Program CODE is entered, press and hold the Freezer Temperature DOWN /- Keypad until the Program CODE begins flashingindicating it has been saved.NOTE: If you attempt to enter an invalid Program CODE the control will not save the new code, but will beep. (The unit will NOT run with a ProgramCODE of 0000).Once the Program CODE has been saved the Programming Mode is exited by pressing any key. If the new code is incorrect thisprocess should be repeated.The Programming mode can be exited at any time by pressing Door Alarm key for 3 seconds or will exit if unattended for four minutes Read More...
Greg February 12, 2015 for Model Number MFI2569VEA If the damper is stuck open does the damper need replaced or does something else need replaced.