Greg February 12, 2015 for Model Number MFI2569 VEA The ice maker wont make ice and the frig gets colder and turns everything frozen. Is this problem the board?
1 Answer Greg, You will want to check the damper that is located behind the icemaker auger assembly which is most likely stuck open. To access you will take the ice bin out. On the left bottom part of the compartment there is a small hole, Put a small screwdriver in there at an angle and push the screwdriver up and slide the panel forward. Then you push the tab on the side of the icemaker and the assembly will come out. Once out check the damper that is located at the back of the assembly. Read More...
Justin February 02, 2015 for Model Number MAYTAG MFI2569VEMO I had a icemaker overfill one night and flood the house. It stopped making ice after that. I replaced the complete icemaker assembly and It will not make ice. It since has started freezing the food in the refrigerator portion. Last night the door alarms starting going off like the door was open when it wasn't. I believe I'm having control circuit board problems? Does this sound correct? I can jump the icemaker diagnosis ports and it runs a complete cycle without trying to fill the ice tray. My main concern is to keep the fridge from ruining the food(freezing it) Thanks
1 Answer Justin, This issue does sound like it could be caused by a faulty control board but you will also want to check the damper assembly which is located in the housing that comes off with the icemaker. If the damper is staying open then it will cause this issue to occur with the freezing in the refrigerator compartment. Read More...
Andy January 17, 2015 for Model Number MFI2269VEB10 I have a problem with refrigerator and freezer sections not cooling. I checked compressor resistance across pins and there are no shorts. The start relay and capacitor seemed OK but I replaced just be sure. This did not solve issue and I still cant hear relay clicking to start compressor. I pulled HV board and brought to work for design engineer to test. Could find nothing wrong with caps or relays and other mounted parts but this was with no power to board . One main 12VDC relay was making a rattling noise so pulled this off the board to test with 12VDC. Relay opened and closed properly so soldered back in place. Followed anti static protocol to make sure not to short any IC's on the board. Re-installed in fridge and now interior lights in refrigerator and freezer not coming on as they did before. All other functions seem Ok but now interior lights not coming on, start relay not seeming to get a signal to activate and start compressor. I even checked program code and it was correct. A technician told me this board was probably bad but cost is bit high to just guess. I seen no obvious burn marks on board or burned resistors caps or shorts to any components when no power applied.Possibly IC is bad on board or another relay on board is bad. My best guess is IC. Do you think I should replace this board? If I install this board and same problem exists is it returnable? I already have a start device and capacitor that I didn't really need. I would hate to purchase something so expensive to have it not be the problem or not be able to return it. Thanks for any help you can provide. regards, Andy
1 Answer Andy, Based on the information that you provided, if the relay to the compressor is not getting power then the control board would be the part that you would want to replace. The board does sound like it will be the issue with the lights not working. If the compressor is getting power but not starting then the compressor is faulty and would need to be replaced. Here is a link to our return policy http://www.appliancepartspros.com/customerservice/returns.aspx Read More...
Cecilio December 18, 2014 for Model Number MFI2569VEM2 Hello, I have a problem and ive looked everywhere trying to resolve it. My refrigerator had a problem and it was the main board. We ordered the new main board, but when we tried to get the refrigerator working again it asked for some codes to reprogram. We have looked everywhere for those codes, but we haven't found them yet. Could you please help us? The model is a Maytatg, and the board code is MFI2569VEM2. THANK YOU!
1 Answer Hello Cecilio. The code is printed on the model number tag. It says code, and then the numbers. Read More...
Derek November 26, 2014 for Model Number GI5FSAXVY02 I just received and replaced the HV board and my display turned on again but it shows me a code PE0 000 and its not cooling its making a noise like its working but its not, also something change in the control panel the up and down arrows for temperature are controlling the water and ice option now and its show's PE0 H2O and PE0 ICE what can I do to erase that code or fix my problem?
1 Answer Hello Derek. You need to program the unit. Programming Mode:NOTE: The Program Code is located on the Serial Plate on this unit after the word Code.1. Press and hold the Door Alarm Keypad .2. Press and hold Freezer Temperature Down Keypad within 3 seconds .3. Release the Door Alarm Keypad and wait 3 seconds.4. The control will display PE to indicate the programming mode.5. Entry is confirmed by pressing the Freezer Temperature Down Keypad once more.6. The control will display the current Program CODE. This value should be validated with theProgram CODE printed on the unit serial plate.NOTE: If the Program CODE is correct, the Programming Mode is exited by pressing Door AlarmKeypad for 3 seconds.7. Press the Refrigerator Temperature Up Keypad or Refrigerator Down Keypad tochange the digit value with each key press.8. The decimal point indicates the selected digit. Press the Freezer Temperature Up Keypad toselect the next digit.9. Once the desired Program CODE is entered, press and hold the Freezer Temperature Down Keypaduntil the Program CODE begins flashing indicating it has been saved.NOTE: If you attempt to enter an invalid Program CODE the control will not save the new code, but willbeep. (The unit will NOT run with a Program CODE of 0000).Once the Program CODE has beensaved the Programming Mode is exited by pressing any key. If the new code is incorrect thisprocess should be repeated.The Programming mode can be exited at any time by pressing Door Alarm key for 3 seconds orwill exit if unattended for four minutes. Read More...
Alban November 26, 2014 for Model Number GI5FSAXVY00 I need the Hv Control Board, is W10213583C the correct number, is there a cross reference?
1 Answer Hello Alban. Based on the model number you provided, you will need to order WPW10310240 for the correct HV board. Read More...
Andre S November 13, 2014 for Model Number GI5FVAXVB02i My refrigerator stopped cooling/Freezing, the compressor is not turning on, there is no sound, however the lights are on in the inside, but not on the front outside door panel, what could cause this to happen, we tried changing out the Start Dev., but that didn't solve the problem
1 Answer Andre, This issue sounds like the unit may have a defective main control board WPW10310240. Read More...
Marek November 04, 2014 for Model Number GI5SVAXVL01 Freezer not defrosting, new main board installed.
1 Answer Marek, You will want to pull the door and shelving out of the freezer compartment and remove the rear cover of the freezer. Once the rear cover in the freezer has been removed you will want to do a continuity test on the defrost thermostat and the defrost heater. If one of these does not have continuity then replace the part. Since the new control board has been installed then one of these 2 parts would be the issue. Read More...
Danika October 23, 2014 for Model Number GI5FSAXVY02 My refrigerator has suffered through several electricity outages within the past month. Problem first started after electricity went out and when it came back the front panel was blank and the unit was not cooling/freezing. The lights inside were functioning. Pressing the panel would see everything lighting up and a beeping noise. Two hours later the refrigerator started working normally and was ok until the electricity went out again about a week later. Subsequent outages resulted in the same thing. Sometimes the panel would start flashing before it came back and beeped when pressed. While flashing the water would function as it went on and off and sometimes so would the light. Sometimes a clicking noise can be heard when flashing. Unfortunately it takes longer and longer to start back working after each outage. It went from 2 hours to 4 to 8 to 24 hours. The current record is 30 hours and counting and I don't think its coming back this time. I was convinced it was just the front panel but last resurrection I heard a clicking noise while flashing more from the back as the cooling engaged and disengaged. It was ok again for after that until the electricity went again yesterday. I've been advised that both boards, front and back, should be changed but neither tech examined either part internally because it's always functional when they get here. Help!
1 Answer Hello Danika, The high voltage board WPW10310240 will be the most likely suspect but it is not possible to say whether the dispense board WPW10162500 has been affected or not. The manufacturer does recommend to replace the two boards together if a power surge has been experienced. Read More...
Kurtis October 21, 2014 for Model Number 59677532601 Have new HV control board does not show program code on serial plate where do I find the code ? Thank you