David July 28, 2013 for Model Number Estate TT14DKXEW14 Whirlpool 2183400 defrost timer Recently repaired my fridge by replacing timer, bimetal, & heater coil - ordered from you. Successful BUT don't understand something....... When bench testing the timers (old and new) - I applied 110vac to terminals #1 & #3. Advancing the timer by hand, #1 switched between #2 for defrost or #4 for cooling as expected. BUT, the timer would not advance on its own over a period of several hours (based on a pencil mark) when it was on the bench but advanced properly when installed in the fridge. I understand there is a capacitor in series with the motor but not sure what impact this would have. Can't sleep for wondering what is happening - thought I had a reasonable understanding of electricity. PLEASE explain why the timer did not advance when on the bench. Thanks
1 Answer Hello David. The timer motor is power through the compressor run of the unit. Ont the bench, you were not supplying power to the timer motor. On the unit, there is power to the timer motor. Thus, the motor advances. Read More...
Patrick July 18, 2013 for Model Number RT18DKXAW00 About 2 months ago my Roper fridge wouldn"t cool properly in both freezer an on bottom.I advanced the defrost timer a bit and it helped,but,now it"s doing it again and advancing it didn't help.What should i do?
1 Answer Patrick, Check the rear wall of the freezer and see if there is frost build up on the wall. If so, you will need to test the defrost heater and the defrost thermostat. They should read closed for continuity when cold. You can test this with a multi-meter TJMA-DMT3. I will include a link at the end to assist you how to use the multi-meter if needed. If both parts are good, you will need to replace the defrost timer. Once the problem is repaired, you will need to thaw out the ice on the coils before the unit will operate properly. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html Read More...
Randy June 26, 2013 for Model Number Estate TT14DK Defrost timer 2183400 Does the timer gear rotate on a time schedule or just when the compressor is running? I have replaced the timer, set it in manual defrost - about 30 minutes later, the compressor starts running but I can't see any evidence that the timer gear is turning after about 8 hours. (I placed a mark on it) Problem is that freezer frosts over and blocks cold air from the bottom of unit.
1 Answer Randy, This timer should be a continuous run timer which means that it will run and advance all the time whether the compressor is on or off. If the timer is not advancing then the timer may be faulty. Read More...
Kj October 04, 2012 for Model Number ET14CKXGW01 My refridgerator runs almost every half hour and my electric bill is going through the roof. What can I do?
1 Answer Hello KJ. Make sure the coils on the back are clean, and if it is cooling properly, but not turning off, replace the temperature control WPW10567140 in the unit. Read More...
Clark June 28, 2012 for Model Number KSSP48QHS00 When looking at the timer should you see the gears moving continuously or only during the defrost cycle?
1 Answer Hello Clark. The gears move so slow, you will not see them turning unless you mark a gear and watch the mark on the timer WP2183400. Read More...
John D February 17, 2012 for Model Number Kssp48qhb00 Defrost was not working. I replaced both defrost thermostat and timer. Defrost heater now only works when timer is turned to manual defrost position. Timer seems to be working and does turn off condenser fan on schedule- but no heat from heater element. What else could be the problem?
1 Answer Hi John. A little conflicting info... If you say the heater works when the timer is manually advanced then there is an issue with either the timer itself or the wiring. Is the pink wire on # 2 timer connection ? Is the Blk on the # 1 ? Is the orange on the # 4 and the red on # 3 ? It also is marked on the side of the timer. Timer part # WP2183400. The heater should have 8-18 ohms resistance. It is part # WP2006751. The defrost thermostat is part # WP4387499. It seems like if the heater fully gets hot then you have a wire connection issue or a timer issue. Let us know what you find and we will continue to assist. Thank You. Read More...
Curt October 14, 2011 for Model Number rt14bkxjwoo Freezer section get frosty and lose air flow to refrigerater section. Changed defrost timer, still the same.
1 Answer Hi Curt. You will need to replace the defrost thermostat and heater. Defrost heater - If you need the defrost thermostat order WP4387490Part Number: WP2263749, made by WHIRLPOOL. Thank you. Read More...
Hailey August 20, 2011 for Model Number kitchen aid side by side KSSS48QDX05 Again, I post the question, "will I receive a diagram with instructions to replace the defrost timer" with my purchase of the defrost timer? Although Parts Pros has answered the how to, I would still like a diagram. Thank you.
1 Answer Hello Hailey! No, an instruction sheet or diagram is not available for the timer WP2183400. Thanks. Read More...
Hailey August 18, 2011 for Model Number KSSS48QDX05 I have purchased a defrost timer and would like diagram instructions of how to replace this part in my refridgeratior. Do these instructions come with the part I have purchased?
1 Answer Hi Hailey. Your defrost timer is located in the top. You remove the front cover by lifting and setting aside. Then you will see the mount screws and the defrost timer knob on the left under the fan cover. You remove the cover and un- bolt the timer. Unhook the electrical connector and reinstall the defrost timer. Make sure that you advance the timer with a large straight blade screwdriver to the 2nd "heavy" click so the timer will start in run time. Hope this helps. Thank you. Read More...