Michael June 20, 2023 for Model Number KTRS22MAWH10 Your instructional video shows an instruction sheet but my part does not have any instructions. Is there a downloadable instruction sheet for the defrost timer (part no. WP2183400)? This would be most helpful in telling me which “version” I have which would tell me which terminal gets the black pigtail wire if any, that is attached to the timer! It is my understanding that this timer replaces a multitude of timers but my original timer has no external wire hence my issue as what to do with the black wire. I think instructions would help me. THANK YOU!!!!
1 Answer Michael, If you got the timer that the black pigtail goes on then the black wire will go to terminal number 2 on the timer. Read More...
George September 09, 2021 for Model Number kitchen Aid refrigerator KSSS48QDX02- defrost timer AP6005994 This will be the forth timer I have purchased. Last repair, I replaced timer, thermostat, and refrigerator sensor. works great for a few months and then unit freezes up again I advance the timer to defrost mode and it then works perfect. The timers keep failing. What con cause this? Thank you for your advice George
1 Answer Geroge, the wiring of the defrost timer may need to be checked to ensure they are lined up on the new terminal sets. The pink wire should be on terminal 2, black wire on terminal 1, orange wire on terminal 4, and red wire on terminal 3. If these are good, the next step would be ensuring that there is not an air leak that could be causing excessive moisture to get into the unit. If these things check good and the defrost heater has a resistance measurement of 19 Ohms, the compressor would need to be checked to identify if it is operating without stopping as this will cause the defrost timer to constantly cycle. Read More...
Keith June 01, 2020 for Model Number KSSS36QHB00 The refrigerator cools to 34-36 degrees. The freezer side only cools to 14 degrees. It has held these temps for almost a year, never changes. Pls. advise. Thx. Keith
1 Answer Keith, the freezer thermostat WP1113466 would need to be tested for 120VAC entering and 120VAC leaving it when the compressor is not running and the unit is at 14°F. If there is not 120VAC at both sides when each wire is tested to ground (using a meter), the thermostat is starting to weaken and would need to be replaced. Read More...
Al September 16, 2019 for Model Number KSSS36MDX05 Unit sat for two years after kitchen remodel, worked fine prior to removal, now installed in garage. Coils at top have been dusted. Both Freezer and Refrigerator are warm. Main fan/motor at the top works. I hear the compressor come on. Fan in the freezer section did not work at first, but when I opened the back and touched the fan, it started working. Has continued to work, but still no cooling anywhere.
1 Answer Hello Al,you did not mention if anything is running, if not access the top coils and turn the defrost timer till it clicks if still nothing the freezer cold control would need to be checked next.,if the compressor/condenser /evaporator fans are running and not cooling there is a system problem. Read More...
Lippee September 05, 2019 for Model Number RT18BKXJW00 This is for Roper RT18BKXJW00. Fridge too warm: I replaced the evaporator fan. I replaced the defrost timer. Fan is not operating still, so what would be the next fix?
1 Answer Lippee, You would need to check to see if there is voltage to the fan motor. You are looking for 120 Vac. If there is proper voltage but the fan is not working then the fan would be the issue. If there is no voltage check to see if there is power coming from the controls to the fan motor. If there is then there would be a wiring harness issue. Read More...
Jason July 04, 2019 for Model Number ET17JKYJWOO My coil keeps frosting up. Replaced the Defrost Bimetal because the plastic was popped up and wire separated. Thought this was it but found out the diffuser was plugged with ice from before I changed the Bimetal. The fridge was warm but the freezer was cold. Now the fridge is cold and the freezer is cold, but how long till the coil frost up. The fridge runs fine after I put the Bimetal installed 8 hours ago. Now it is starting to do the same thing. Please help me with this. It is either this timer or the heater. How do I check the timer? thanks
1 Answer Jason, the sure way to find if the defrost timer WP2183400 is the issue would be to eliminate the other components as the possibility. As the bi-metal has been replaced, the next thing to check would be the defrost heater WP2263749. The defrost heater can be tested for resistance and should read between 28 to 32 ohms. If the heater checks good, then by process of elimination it would be the defrost timer is not cycling through the cooling cycle when the compressor is operating. Read More...
Valerie W November 15, 2017 for Model Number ktrs19kdal01 Do you have a video for the defrost timer on the kitchenaid ktrs19kdal01 because the timer is in the refrigerator.
1 Answer Valerie, To access the timer in the refrigerator section you would remove the screws holding the control panel in place and drop the control. You will have access to the timer at this time. There will be no video for the timer replacement. Read More...
Tom April 05, 2016 for Model Number KSSS36QDW00 My refrigerator isn't cooling properly although the freezer is; the vent between the freezer and refrigerator compartments is open and the fan to move air between the two compartments is working; air flow seems to be minimal coming from freezer to refrigerator. The return vent between the freezer and refrigerator is open as well. I noticed the coils behind the freezer compartment--where the fan is to circulate air--have a lot of ice built up. I'm wondering if this is causing a restriction in the air flow between the two compartments. Is it normal for the coils in the freezer to be covered in ice? Could that be a faulty defrost timer? Does the coils in the freezer also have a heater to defrost the coils? Thoughts on where I should start?
1 Answer Tom, The coils should not have a lot of frost on it. If there is heavy frost build up you will want to do a continuity test on the defrost heater and defrost thermostat. If there is continuity on both then the issue will be a faulty defrost timer. If there is no continuity then replace the part that does not have continuity. Read More...
Kenny August 15, 2015 for Model Number Estate refrigerator tt14dkxr00 Refrigerator runs good for 4 or 5 hours and kicks breaker tried different outlets 20 and 30 amps same problem, refrigerator is level and clean
1 Answer Kenny, You will want to check the defrost circuit to make sure that the heater is not burnt and touching metal. Also check the defrost timer to make sure that it is good. Read More...
Vincent April 19, 2014 for Model Number TT18DKXEW03 whirlpool refrigerator/freezer, freezer goes to 16 below ices up, changed defrost thermostat, checked heater ok,checked defrost timer, applied 110volts to terminal 1 & 3 timer motor runs when manually set to defrost mode, when put back in frig timer doesn't advance after defrost cycle what would power the #4 terminal? model# TT18DKXEW03 serial# EF2319854
1 Answer Vincent, The black coming through the unit is the L1 circuit and the orange wire goes to the thermostat. This is where the power comes from. It sounds like the defrost timer is sticking as the motor will switch the terminals from the defrost circuit number 2 terminal to the cooling circuit number 4. Read More...