Michael L. January 21, 2014 for Model Number Maytag Washer/Dryer Model LSG7804AAE s/n 15212382MW Please provide technical direction on what part to try next. I just installed all four parts purchased per Order #4016646. Prior to these parts I had also replaced both gas coils (purchased locally). SYMPTOM: The drier is not keeping the air hot, so that it is not drying. A damp towel is still damp and cool after 30 minutes on Normal. The drier ignites and burns a flame for about 30 seconds, then goes off for about a minute, then on for only about 8 seconds. It makes no difference to disconnect the vent from the back, so I know that a clogged vent is not the issue. With the vent disconnected I feel a strong air flow out the back. WHAT DO I TRY NEXT? Also, how long should the flame stay lit? (I would like to know what to look for when it is working properly.)
1 Answer Hello Michael, This is the symptom of either a weak gas valve coil or a failing gas valve. Since you have already changed the coils, the gas valve will be the issue. If you ordered the gas valve coils from appliancepartspros.com, we will refund them, since the gas valve should come with the coils. The substitution gas valve is part number TJ25M01A-100 since the original is no longer available. This part will ship in 5 to 6 business days from the order since it is not in stock at this time. This does not mean it is not available, it only means we will need to order it and ship it as soon as we receive it since it is still available. Read More...
Ed S January 14, 2014 for Model Number Kenmore model 110.96562500 My dryer wasn't heating and I noticed the glow bar (igniter) part #686590 wasn't glowing red, so i replaced that part. It turned red the first time I attempted to run the dryer, but the gas did not flow and the system did not work. I checked the thermal fuse and found out that it is bad. Will a bed thermal fuse ruin a new igniter? Will a bad flame sensor ruin a new igniter?
1 Answer Hello Ed. No, but if the parts are bad, they will prevent the igniter from glowing. Read More...
Tracy July 29, 2013 for Model Number MDG5500AWW Hi, my Maytag Dryer did not heat up. I replaced the Ignitor and it worked great for 3 loads and now it doesn't ignite again. Any suggestions?
1 Answer Hello Tracy. You will need to test the thermostats and the flame sensor and make sure they are good. They should read closed for continuity. Here is a link on how to use a multi-meter for the testing procedures. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html Read More...
Frances M April 26, 2013 for Model Number Maytag LDG313 gas dryer My gas dryer igniter comes on but the flame will not come on but, I smell natural gas. I have replaced the coils and the igniter but not luck. Someone suggested maybe its the flame sensor but, I have no flame. what could cause the gas odor?
1 Answer Frances, The flame sensor works in conjunction with the igniter get the unit to start up. You will want to check to see if the flame sensor reads continuity. If the sensor has continuity then it is good and if no continuity then you would need to replace the flame sensor. Read More...
Brad July 31, 2012 for Model Number Maytag LDG8626AAE DRYER- GAS The dryer runs and the blower motor works fine. I get no heat. I have cleaned and replaced the Flat style dryer igniter (AP3109449. I also replaced the Dryer main coil and Secondary Dryer coil. Still no heat. I do not hear the start up click and the coil never glows. Yes, the dryer is getting gas. Help! What next?
1 Answer Hello Brad, You need to check the thermostats, (hi-limit and cycling), the flame (radiant) sensor, and the centrifical switch in the motor. The temperature switch or timer could also have problems. The thermostats and radiant sensor should show continuity when room temperature. The timer should show 120Vac at the blue wire. The centrifical switch will read open unless manually operated with a screwdriver. There should be a copy of the wiring diagram in the control panel of your unit. Be aware that the thing that causes this complaint is usually connected to the exhaust ducting. You should know that a heat producing appliance has to be able to get rid of the heat, or the heat will cause damage to the internal components. Make sure the ducts are clear, not crimped, and short and straight as possible.Let us know if we can lend further assistance. Read More...
Richard July 22, 2012 for Model Number MDG4000BWW Dryer seems to be working fine but when heat is needed I am getting a single loud POP when the gas(Propane)ignites.
1 Answer Hello Richard. Based on the information you provided, it sounds like the igniter 4391996 is bad and will need to be replaced. Read More...
Curt June 09, 2012 for Model Number MDG9306AWW This is the second igniter I have changed on this particular dryer. Is there something else that could be causing this problem of going thru igniters? Please let me know if there could be another problem? Since the last time I changed that igniter, the town municapality has cut off the gas to several homes in the area. I have had to go and relight water heaters stoves and other gas appliances. This does not sound like a gas issue. what do you think could be causing the gas igniter to keep failing. Please help Thank You Curt
1 Answer Hello Curt, The ignitors are man made, so they may be just lasting as long as they can. The other possibility is that the exhaust duct could be clogged, crimped, or just too long and complicated. You see, the air inlet from the room air cools the parts inside the unit as it is drawn in before it passes across the heat of the burner. If the exhaust is "restricted", it can cause premature failure of any of the internal unit parts. You could also check the voltage at the outlet to make sure it's not above the maximum tolerance, (108Vac to 132Vac). Read More...
Benny April 29, 2012 for Model Number Kenmore 70 series gas dryer I own a kenmore 70 series gas dryer. When I start the dryer, the igniter glows and the burner fires shortly thereafter. However, after 20-45 seconds, the burner shuts off. I have tested the continuity of all sensors, and they all seem to be fine. Also, in auto dry mode, the dial does not advance.
1 Answer Hello Benny. Check and see if the vent is clogged on the unit and is allowing the unit to get to hot. If so, this will cause the issues you are having on the unit. Read More...
Bob April 28, 2012 for Model Number Maytag Dryer Model MDG5500AWW Hi. I also have the same issue with igniter glows red, gas fires up for about 15 seconds then both igniter and gas shut off completely. Based on my reading in this thread that igniter may be weak but it passed continuity test. Is the igniter has to be glowing red hot entirely during drying cycle? I replaced new coil but still experience the same issue?
1 Answer Hi Bob. This can be a plugged or kinked vent or a flame sensor that prematurely opens part # WP338906. Make sure the vent is entirely clear and not restricted. Make sure the outside vent cap / hood is opening and closing properly 4-5x /yr. so lint and moisture does not back up and create a restriction causing these issues. The igniter part # 4391996 should ohm out to 50-400 ohms at room temperature. Use a volt/ohm meter part #@ MA-DM1 to assist you in your diagnostics. Look at the center of the igniter and see if there is a hairline crack that may open during heating. Are there any lint built up around the motor ? Are you getting 120 vac to the dryer and the cord connections tight ? Are you getting 24 dc at the heater relay on the board. Ohm out the heater relay coils and see if they are between 350-450 ohms. Does the relay contacts close and send the 120 vac onto the wire and then the relay prematurely opens? The dryer thermistor part # 307208 on the blower housing should read 10,000 ohms at 77°. If it is more then 10% value then replace it. It will be advantageous to find the supplied tech sheet inside the cabinet to aid you in the diagnosis. It allows you to put the unit in a diagnostic mode which brings up fault codes and tells you which circuit needs assistance. Thank You. Read More...
Tien N. March 26, 2012 for Model Number DG842 I tested the continuity for the igniter and it is open. My dryer has no heat. Do I need to replace the ignitor first?
1 Answer Hello Tien. Based on the information you provided, if the igniter is open, you will need to replace the igniter 4391996 in the unit. Hope this helps. Read More...