Dino P March 22, 2017 for Model Number JAS9800AAB Purchased the new dual Burner switch ( 12002125) for my Jen air JAS9800AAB followed instructions for proper wiring except there is an extra blue wire that instructions don't mention. Any idea where the is blue wire gets connected to?
1 Answer Dino, There is no JAS9800aab, we're going to need a proper model number to assist you with the wiring diagram. In the mean time, there should be no "extra blue wire that instructions don't mention" There should be No extra or left over wires, at all. Get us that model number so we can get your range wired up correctly and get you up and running. Thanks, Read More...
John A March 06, 2017 for Model Number JED8430ADB The lower right burner only heats up on the outer ring. The inner portion no longer heats up. Does that mean the heating element is faulty or is it something that is supplying the power to the unit that is faulty?
1 Answer Hello John. You will test for power to the element. If there, replace the element. If not there, replace the switch. You can test this with a multi-meter TJMA-DMT3. Here is a link on how to use a multi-meter. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html Read More...
Ken December 23, 2016 for Model Number JED8430ADB I purchased a replacement Dual Infinity Switch (PN 12002125) for my Jenn-Air cook top, to replace and the original switch PN # 71001612. Please advise the correct wiring hook up on the new switch. Wiring hook up on the original switch as follows: Pink - 1 double Red - 2 Single red - 4 Yellow - 6 Gray - 3 Double Black - 2 Thanks Ken
1 Answer Hello Ken. The following is the instructions for your switch. 1. Double RED: N -> P2 (incoming power, Line 1) 2. Single RED: N -> 2 (to Inner AND Outer heating elements common wire) 3. Single BLK: L1 -> P1 (incoming power, Line 2) 4. Single TAN: H1 -> 4 (to the Inner heating element) 5. Single YEL: H2-> 4a (to the Inner heating element) 6. Single BLK: P -> S2 (to the R.F. indicator control light) 7. Attach jumper black wire (included with new switch) from P1 (P1 has two connectors close together) to S1. *On units with a compound connection, the two red wires must be separated. Locate the right front switch connection (L2). The red wire routed from the right rear element/switch will remain, but the red wire routed from the left rear element/switch must be disconnected, re-terminated and connected to position 2 on the new dual switch. *On units with an L2 piggyback connection, the two red wires must be separated. Locate the red wire routed to the L2 supply and connect it to position P2 on the new dual switch. Locate the red wire routed to the element and connect it to position 2 on the new dual switch. *On all other applications, the wire connected to the element should terminate to position 2 on the new dual switch. Read More...
Dux4all October 25, 2016 for Model Number JES9800AAB I purchases a replacement infinite switch and received the 12002125. Like most of the other questions I'm concerned about proper wiring between two dramatically different (at labeled different) switches. I didn't see any direct solutions for this model. My wires are as described below. Please help redirect them to the proper switch contact on the replacement switch. Thanks, Single Black wire Double Red wires Single Blue wire Single Orange wire Single Tan wire Double Black wires. I appreciate any help. Thanks,
1 Answer Hello dux4all. Look at the numbers on the back of the old switch and use the instruction sheet provided with the part to match the wires to the new switch. I have located a link to our free repair forum with installation information regarding part number 12002125. Hope it helps! http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/107517-dual-infinite-switch-replacement.html Read More...
Larry May 09, 2016 Spent two hours trying to identify wires and connect to dual element control. I finally gave up in frustration. Can I request a research solution?
1 Answer Hello Larry, We would be happy to research this for you if you could please post a new question with the model and serial numbers from the units' I.D. tag. This will enable us to look up the part numbers and wiring diagram so we will be able to provide you with accurate information for application on your specific appliance. Thank you for your patience and understanding in this matter. Read More...
Jason January 23, 2016 JED8430ADB L2 has TWO red wires on ONE red connector. I believe this is a "piggyback". The L2 on my original switch has one wire that goes to supply and one wire that goes to the other switch on the right. The directions say to split the L2 and put the L2 from supply to P2 on new switch, and the red L2 from the element and put it on 2 on the new switch, but my L2 red wire doesn't go to an element, it goes to another switch. What do I do? Am I supposed to use the jumper that came with the new switch? My old switch has no such jumper. But the directions seem to indicate I'm supposed to use it.
1 Answer Hello Jason, If you follow the instruction sheet, the new infinite switch should operate properly. I have looked up and studied the wiring diagram and the instruction sheet for the new switch and see no problem with the instructions given. You seem to have a grasp on the steps required to complete your repair. Read More...
Paul January 20, 2016 for Model Number SCE30600W I used your instructions to other customers to wire my new Infinite switch (part # 12002125) to my dual burner and it now works properly. I wired; Dual Black to P1, Single Red to P2, Orange to 4a, Purple to 4, and short orange (burner "on" indicator light) from light to S2. *But the indicator light will not function. When I jump the next burner's indicator light wire to it, it illuminates when i turn the other burner on, so the light works as it has in the past. Any ideas why the indicator light won't work from the S2 terminal?
1 Answer Hello Paul. It sounds like you need to check the wiring for the switch on that indicator light. If it worked for the other one, the switch is fine. Read More...
Mike W December 30, 2015 for Model Number CCE3401W series13 could you give me the part number of the duel element switch and how to wire?your forms talk about series 11 not 13
1 Answer Mike, The part number for the infinite switch for the dual element is 12002125. The part comes with instructions for the wiring. Read More...
Steve May 27, 2015 for Model Number Jenn Air CCE3401 Hello: I have a Jenn Air model CCE3401. I ordered dual infinite switch # 12002125 for dual back burner. Instructions with the switch are vague and confusing, however, I found the answer to the wiring on this forum using the following: double red is separated. The red wire going to the element to number 2 of the new switch. The red hot wire (L2) to P2. The black wire to P1 on the new switch. The blue wire to number 4 on the switch. Violet to 4a on the switch. Orange to S2 on the new switch. Black jumper sent with the new switch connects to one end to the other P1 terminal then then the other end to S1 of the new switch. My problem is both element are on high; cannot control low to high range. Does this indicate that I wired red wires on my switch reverse?
1 Answer Steve, It sounds as though you may have received a bad switch. You do have the switch wired properly and the switch being defective would be the only thing it could be. Read More...
Barttech February 19, 2015 for Model Number Amana AK2H30 (P8597804S) Amana Burner switch 309550 is no longer available. Can burner switch 12002125 be wired to replace the old switch
1 Answer Hello Barttech. No, the switch you need 0309550 has been permanently discontinued by the manufacturer and we don't know of any source or replacement for the part. Read More...