Skip to Content
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Trusted Since 1999 Trusted Since 1999
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google

Customer Questions and Answers for Range Oven Door Lock Motor And Switch Assembly by Whirlpool

Best Seller
Manufacturer Part
4.89 (64)
By: Whirlpool
Part Number: OEM18045045
Manufacturer Part Number: WPW10107820

This assembly includes the motorized latch mechanism and integrated switches that lock and unlock the oven door during the self-cleaning cycle. It secures the door shut when the oven reaches high temperatures and signals the control board when the door is properly latched. Replace this part if the oven door won't lock or unlock, the self-clean cycle won't start, or you receive a door lock error code.

More
$134.95

IN STOCK
Ships Today Guaranteed
Add to Cart

Questions & Answers

For Whirlpool Range Oven Door Lock Motor And Switch Assembly (Part Number: OEM18045045)

1 Answer

Hello Todd. Door latch not operating
(Clean mode). 1. Verify failure on diagnostics screen 5. Clear the error code by pressing the START
key.
2. While in diagnostics mode press AUTO CLEAN key to run lock motor.
a. If the door is not latched (locked) and the door locked icon is lighted,
go to Step a1.
1. Unplug range or disconnect power.
2. Check integrity of latch mechanism from cam/eccentric, through actuating
rod, to latch pawl and door slot.
3. Ensure that pawl aligns with the door slot. Correct any mechanical
malfunction and go to Step 3.
b. If the door is latched (locked) and the door locked icon is not lighted,
go to Step b1.
1. Unplug range or disconnect power.
2. Replace motor assembly and go to Step 3.
c. If the door is not latched (locked) and the door locked icon is not lighted,
go to Step c1.
1. Unplug range or disconnect power.
2. Check continuity of the latch motor and the electrical connections between
oven control and motor.
- If continuity is present, replace control. Go to Step 3.
- If continuity is not present, replace motor assembly. Go to Step 3.
3. Replace all parts and panels before operating.
4. Plug in range or reconnect power.
5. Put range into Clean mode to verify proper operation.
6. Verify normal operation. Go to Step 1 and complete checks.

Read More...
Jon

My oven and cooktop stopped working in middle of use. The display still works and it showed a code of F9 which seems to be the door lock switch. All the conections are good and I have not switched the part out yet. When I was looking at the connections I noticed what looks like a capacitor right below the switch had a brown spot like it got really hot. Would I have to replace it also. If so what is the part number and is it as easy as the switch to replace. I have an Whirlpool electric oven with a flat top. Im not sure the model # but the breakdown looks like #rf362lxsq0. Thanks for any help you can give me.

1 Answer

Jon,

The door latch assembly does look like it would be the issue with the unit and would need to be replaced.

Read More...

1 Answer

Hello Millie,
Check the wire harness from the door switch and the latch switch to the control board. If it shows a problem, replace the door switch. Press and hold any key for 1 min, then press cancel to erase the F2. If that doesn't take care of the problem, replace the control board. This is assuming that I am referring to the model you actually have in your home. Since no model number was listed, I just ran with the fault code. If you require further assistance, please include the model number found on your units' I.D. tag so we can be specific and we can include part numbers if needed.

Read More...

1 Answer

Jeffrey,

The F5E2 error code represents that the door and switches do not agree. You will want to make the following checks.

1. Verify failure code shown in diagnostics mode screen.
2. Unplug range or disconnect power.
3. Check wires and connectors between control and door switch.
4. Inspect door for warping or misalignment. Verify door switch continuity with switch fully depressed manually.
5. If no damage to wires or connectors, replace door switch.
6. Replace all parts and panels before operating.
7. Plug in range or reconnect power.
8. Press CANCEL/OFF key, program and start the Clean mode, and observe for 1 minute to ensure that operation is normal.
9. Verify operation is normal.

Read More...

1 Answer

Hello Bob,

This is the failure code for the door latch assembly WPW10107820. Specifically the manufacturers' code reads that the door latch is not operating.

Read More...

1 Answer

Tom, The issue would be in the switch or wiring. The control board has to see the switch circuit change, in order to stop the motor, and the switch circuit tells the control to start the cycle. So check the switch circuit for a change and the wires from the switch to the control board. Good Luck and Thanks

Read More...

1 Answer

Hello Phil. You can release the door latch assembly WPW10107820 using an ice pick and sliding the latch over. Then you will need to replace the latch and the control board on the unit. Hope this helps.

Read More...

1 Answer

Hi Tony. Remove power. Open thew door and remove it by securing the latch locks first. Then lift up and out on the door. Then remove the front lt. and rt. underside screw that hold down the front of the smooth top. Lift up and support the smooth top underside in the up position. Then you need to mark all elect. connections so you know how to reconnect them (cell phone picture). Then remove and replace the switch assy. Part # WPW10107820. Thank you.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google