Customer Questions and Answers for Spark Module by Whirlpool

Best Seller
Manufacturer Part
4.89 (64)
By: Whirlpool
Part Number: OEM18059193
Manufacturer Part Number: WPW10331686

The Spark Module is an OEM replacement part for Whirlpool ranges. It is an electrical component that generates the spark needed to ignite the gas burners. By sparking consistently and reliably, the module allows the cooktop burners to ignite with each use. 

Causes of a bad spark module can include normal wear and tear over time, exposure to moisture or residue, or issues with the electronic components that produce the spark.

Symptoms of a bad spark module include:

  • Burners that will not ignite or light consistently  
  • Burners that ignite but then immediately go out
  • Only some of the burners lighting while others do not
  • A clicking sound coming from the ignitors but no visible spark

Note: For harness from spark module to igniters use part number 9756892.

This OEM Whirlpool replacement spark module is also compatible with Maytag, KitchenAid, Jenn-Air, Amana, Magic Chef, Admiral, Norge, Roper, and Kenmore models. 

More
$226.54

IN STOCK
Ships Today Guaranteed
Add to Cart

Questions & Answers

For Whirlpool Spark Module (Part Number: OEM18059193)

1 Answer

Hello Ms. Tee. Most likely the control board WP9760013 will need to be replaced on the unit. It sounds like it shorted the control when he did that.

Read More...

1 Answer

Brian,

You will want to check the resistance of the gas valve WPW10293048. If you check from common to bake and common to broil the resistance of each reading should be approximately 216 ohms. If not the valve would need to be replaced.

Read More...
Clark for Model Number SF362LXSB0

My oven and broiler will not light up.when I turn on the oven I hear a real faint click and when I turn on the broiler I hear two louder clicks. I don't smell any gas. There have been a few times in the past when using the oven, and I turn the oven temp to a lower setting, the oven quits igniting. For this reason I'm thinking it's a bad gas valve. Would I smell gas if it were the spark control module or bad igniters? Or would the igniters spark or glow if it were a bad valve? And if it was a bad spark module, would both the oven and would it be likely that both the oven and the broiler quit at the same time and would I smell gas?

1 Answer

Clark,

You will want to check the oven safety thermostat for resistance. The resistance value of the oven safety valve, from bake to common and from broil to common, should be 216 ohms each. If the resistance is not correct then the safety valve would need to be replaced.

Read More...

1 Answer

Archie, You most likely have a weak or faulty re ignition circuit in the DSI spark module WPW10331686. You may want to test the DC volts to the gas valve across the red and orange wires, there should be 8 to 18 VDC if the module is working correctly, If you have the DC volts, then the gas valve WPW10293048 would be the issue.

Read More...

1 Answer

Archie, The most likely issue is the bake burner igniter circuit on the DSI spark module, it's weak or has failed. It isn't supplying the 8 to 18 VDC to the igniter, so it won't spark. Also check and make sure there are no lose wires or connections at the spark module and the gas valve.

Read More...
Jim for Model Number Whirlpool #GS563LXSS0

Just replaced the igniter thinking that was the problem but it still is doing the same thing. The igniter sparks oven lights for a few seconds then the flame goes out but the igniter still sparks a few times after the flame goes out. I was told buy a repairman that the igniter has a flame sensor but apparently not. Is the flame sensor built into the igniter module? Just wondering what to do next? Everything else on the range works just fine. Thank you Jim

1 Answer

Hello Jim. You need to check for a grounding issue with the burner in the unit. It is not grounding and is not sensing the flame is lit. Also, check the igniter wiring to the burner.

Read More...

1 Answer

Sandy, Yes replacing the DSI Spark Module WPW10331686 and checking the wires for loose connections would be the "next step", replacing the gas valve WPW10293048 would have resolved any weak or open gas valve solenoid, or possible orifice issue. You most likely have a weak or inoperable re ignition circuit in the module circuitry or the bake circuit.

Read More...

1 Answer

Frank,

The unit is not designed for the both the bake and broil burners to operate at the same time. When in bake only the bake burner will operate and the same as the broil burner will only work when in broil. All the test that you did are good readings.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google