The Spark Module is an OEM replacement part for Whirlpool ranges. It is an electrical component that generates the spark needed to ignite the gas burners. By sparking consistently and reliably, the module allows the cooktop burners to ignite with each use. 

Causes of a bad spark module can include normal wear and tear over time, exposure to moisture or residue, or issues with the electronic components that produce the spark.

Symptoms of a bad spark module include:

  • Burners that will not ignite or light consistently  
  • Burners that ignite but then immediately go out
  • Only some of the burners lighting while others do not
  • A clicking sound coming from the ignitors but no visible spark

Note: For harness from spark module to igniters use part number 9756892.

This OEM Whirlpool replacement spark module is also compatible with Maytag, KitchenAid, Jenn-Air, Amana, Magic Chef, Admiral, Norge, Roper, and Kenmore models. 

More
$226.54

IN STOCK
Ships Today Guaranteed
Add to Cart

Questions & Answers

For Whirlpool Spark Module (Part Number: OEM18059193)

Sherry for Model Number WFG374LVQ1

I've had the reignition board replaced once about 15mos ago (of course it's past the parts warranty) and it appears that it needs to be replaced again. Same issues as before...the oven / bake element would intermittenly not light...sometimes when just starting, other times while in the middle of baking. Now it will not light at all tries to ignite 4 times and then shuts off to only try again a bit later, without success. How difficult is it for a fairly handy / technical consumer to replace this part? It is a Whirlpool free standing range/oven Model # WFG374LVQ1 Serial # RY4314267 Thank you, Sherry

1 Answer

Sherry,

You will want to check to make sure that the coils on the safety valve are not bad. You would want to do a resistance check on the coils between bake and common. Common is the center terminal. If the resistance values are not 216 ohms then the valve is faulty and would need to be replaced. You could also put an amp meter on the igniter and check to make sure that it is getting 3.2 to 3.6 amps. If the unit is not getting proper amperage then the igniter would need to be replaced.

Read More...
John Y for Model Number GS773LXSSO

I have a Accubake oven but the bake and boiler have no flame. There is no click on bake and two clicks on Broiler. I replaced the main circuit board and the bake and broiler still do not have flames. I tested the J1-1 (red wire) and J1-2 (orange wire) for continuity to the Bake valve and the circuit is open. I tested the J1-2 (orange wire) and J1-3 (blue wire) to the broiler for continuity and the circuit is closed (circuit is complete). Is it the spark module, wiring to the bake valve or gas distribution valve? John.

1 Answer

John,

If the J1-1 to J1-2 is showing as an open circuit then the safety valve is faulty on the bake side. You will want to check for amperage on the broil side igniter to make sure that it is getting 3.2 to 3.6 . If not getting proper amps then you will need to replace the igniter.

Read More...

1 Answer

Hello Sarah,
If we could please ask you to send us the model number off of the units' I.D. tag, we will look up the service manual or equivalent illustrated instructions and send them to you. I'm sorry to put you to this additional trouble, but it's all in the interest of sending you accurate information.

Read More...

1 Answer

Arek, There's more involved than just the spark module WPW10331686 It could also be due to a faulty regulator gas valve WP9763716 here's some help: First thing, check and make sure the power cord is attached to a properly polarized and grounded 120 VAC outlet. A proper ground is very important for the range to operate properly. Then you'll need to make several tests at the gas distribution valve. You'll need a multi meter to test voltage and resistances. At the valve body terminals, with the wires labeled and remove from the middle terminal to each of the outer terminals, you should read 215 ohms resistance. With the wires reconnected, when you select the bake cycle, you should have a reading of 8 to 18 VDC across the red and orange wires. When you make a broil selection you should have the same 8 to 18 VDC,across the orange and blue wires. If you don't receive the VDC at the gas valve, the module is at fault, if you have the VDC at the valve, then the valve is the most likely issue.

Read More...

1 Answer

Hello Bernie. Based on the information you provided, the spark switch is bad and will need to be replaced on the unit.

Read More...

1 Answer

Hello Jill,

You will want to check your oven safety valve. Check the resistance from broil to common and from bake to common. You should read 216 ohms of resistance. If you have proper resistance then the ignitor would be the problem.

Read More...
Amp for Model Number SF462LXSQ0

The stove top burners work correctly, the oven will only make 2 clicks at the gas valve and no spark at the igniter when setting the bake mode. When holding a match to the burner, it will briefly begin to light as the valve solenoid clicks. In the Broil mode nothing happens, no sparks or clickng of the gas valve. I tested the ignitors and they are fine. If I set the DVOM on AC voltage it reads 25 volts all the time at the spark igniter, but in holding the test probe on the connection at the igniter and trying to start the oven, the gas valve wont even click twice. Only if I remove the test probe will it click the gas valve twice but nothing else happens.

1 Answer

Hello Amp,

Based on the information provided it sounds like you would need to replace the Spark module.

Read More...
Chris B for Model Number Sf362lxsq 0

I have a couple year old range. The burners worked but the oven does not heat. I believe I hear the unit is sparking. Does the spark igniter ignite both the burners and oven because if so the burners are ok so this might not be the bad part. The gas valve is newer but I was told by the prior owner that they had water in the basement. The electronics however seem to be ok. There is a little bit of corrosion on the contacts but I cleaned them lightly.

1 Answer

Hello Chris,

You will want to do a resistance check on the safety valve. The resistance should be from bake to common and from broil to common 216 ohms. You have 2 ignitors in the oven, one for broil and one for bake. If both units are not working and the ignitors are sparking then more than likely it is the oven safety valve WPW10293048. You can test this with a multi-meter TJMA-DMT3. Here is a link on how to use a multi-meter. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html

Read More...

1 Answer

Hello Robert,

First you will want to check the safety valve. Check the resistance on the valve from bake to common and from broil to common. You should have 216 ohms. If this checks ok then you would want to replace the spark module.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google