1 Answer

Todd,

To convert this unit to Natural you will need the following orifice for your range top would be the following: The Left front and Right rear orifice will be W10156136, the RF W10156836 and the left rear is part number W10156137. The oven orifice you loosen 1 1/2 to 2 turns and close off air shutters to about a 1/4 way open. The regulator will need the cap flipped from LP to Natural.

Read More...

1 Answer

Martha,

Unfortunately with this being a Sears product and they do not list which orifice goes where, we would not be able to assist with the part numbers but you will need just the top burner orifices.

Read More...

1 Answer

Hello William! You will need to flip the cap on the regulator back to NG to convert the oven over. The right front NG orifice is part number WB28K23, the right rear NG orifice is part number WB28K86, and the two left burner NG orifices is part number WB28K19. Unfortunately, the right rear burner orifice and left rear/left front burner orifices have been discontinued and are no longer available. I would suggest contacting the manufacturer to verify their stock of the discontinued items, without these you will not be able to complete the conversion.

Read More...

1 Answer

Shawn,

There are several parts that will need to be changed to convert back to Nat gas: WP234826 orifice, WP694424 Limiter/cap, WP694423 regulator sleeve, and WP694422 spring. These parts are all associated with the brass cap fitting on the top of the gas valve and must be replaced in order to convert the valve back to Natural Gas and have the valve operate properly. Don't forget to check for possible gas leaks at the valve once the parts are installed and the gas supply is reestablished, you can use a solution of soapy water and a rag or old paint brush to swab the solution on the fittings.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google