Donna September 14, 2023 for Model Number KUIX505ESS2 The water fill into the water bin doesn't stop when the bin is full. The water continues to flow causing the bin to overflow on to the ice below. Is there a sensor that needs to be replaced the senses when the bin is full of water? Is it built into the water recirculation pump or the water fill valve? Trying to determine what part needs to be replaced so that the water will shut off when the bin is full.
1 Answer Donna, if the valve W10897719 is not receiving 120VAC but it continues allowing water through, it has failed and would need to be replaced. However, if the valve continuously receives voltage, the main control W11034363 would need to be tested after turning off the water supply. At connection P8, DC voltage would be tested from the black wire with a white stripe at pin 6 to the brown wire at pin 4. If there is not 14VDC, the main control has failed. If there is, the next step would be testing from the yellow wire with red stripe at pin 1 to the brown wire at pin 4. If there is not 5VDC when the water reservoir has water in it, the pump W11542867 has failed. If the 5VDC is present, the main control has failed. Read More...
Victor June 02, 2023 for Model Number KUIX335HP500 This unit has 2 pumps but the breakdown only shows one pump for the water circulation. Which is the correct pump?
1 Answer Victor,The two pumps for the model are as follows W11542868 / AP7019076 Pump, Reservoir Drain AND W11542867 / AP7019075 Pump, Recirculating (Includes Sensor) Read More...
Wendy June 02, 2023 for Model Number kuix505ess1 Hi. The machine is making ice (though smaller and cloudy), but the water will drain out (or be pulled out) of the pan periodically resulting in very little water getting pulled up onto the chill plate. Would this be a pump issue? It sounds like the pump is struggling. Water is getting to the reservoir, just doesn't seem to stay there long enough to make the clear ice and correct thickness.
1 Answer Hello Wendy, if the water reservoir is filling correctly and the recirculation pump is running then yes most likely the drain pump may be leaking water out of the reservoir causing the ice making to short cycle. Read More...
Xavier June 02, 2023 for Model Number WUI95X15HZ00 Is this the pump that pumps water on to the chill plate? If not what part does it? Everything seems to be working other then water is not making it to the chill plate.
1 Answer Hello Xavier, that part is the drain pump, and the water recirculation pump is part W11542867. Read More...
Carlton Moore May 01, 2020 for Model Number KUIC15NHZS0 Water not flowing across freeze plate. Replaced pump and had to tap on it to make it run. Ice maker will run and make ice until full but will not turn on. I can tap on it with the screwdriver handle and it will run. I removed the pump thinking it was an alignment problem and reinstalled but it is still doing the same thing.
1 Answer Carlton, It would be recommended to check the connection for the pump as it may have a bad connection and may require a new wire harness for the unit. Read More...