1 Answer

Hello James,

There are only two possibilities and it could be a combination of the two. You see, when air fluff is chosen, you break 120Vac off of the heater element. If the exhaust duct is restricted, heat will be held in the unit and appear to be still heating because the heat is blown past the felt dryer drum seals back into the cabinet where it is recirculated. The other possibility is a heating element WPY308612 shorted to ground, causing a medium heat situation anytime the unit is running. While this is possible, it isn't likely because, as I said, this would be a medium heat situation. Since the heating element is designed to run on 240Vac, and if it's shorted to ground it will only have 120Vac on it, it would appear to be on low or medium heat at all times.....unless the exhaust duct is crimped or clogged.

Check the exhaust for crimps or clogs as this is the most probable cause and the most denied by customers. Remember the duct should be as short and straight as possible while being a full 4 inches for proper air flow.

Read More...

1 Answer

Hilo, A quick and easy check/repair : Unplug the power cord or remove power to the dryer. Open the dryer door using a 1/4 in socket or nut driver rmove the sensor bar mounting screws(2) and lift upi on the sensor bar assembly 33001809, make sure both wires are attached to the terminals, carefully disconnect the wires(don't let them fall back into the cabinet) and clean the bulkhead area and back side of the sensor with a solution of warm soapy water. Clean the top side of the sensor bar with rubbing alcohol, and reinstall the sensor. Put a small load of damp articles in the dryer and start the machine, if it runs longer than two(2) minutes, you'll be fine. Thanks

Read More...

1 Answer

Hello BBMello. Check the thermistor WP31001590 and make sure it is good. If so, It sounds like the venting system is clogged or kinked. You will need to check the vent and clean it out. Be sure and clean the vent pipe and the dryer air duct assembly. If the air flow is not good, the unit will retain moist air causing the clothes not to dry. Try running the unit with the vent unhooked from the back of the dryer and see if the dryer works properly.

Read More...

1 Answer

Hi HT. Create a log in on our website and insert your model in in the start here home page. Then scroll down to the lt. side and bring up tumbler view # 6. Under the part # 11 it shows the part #10 green ground wire. Your serial # may have not included this part. No-there are only 2 wires that hook to one end of the sensor bar as the opposite end tabs are folded to hold the bars in the mount. Use a ohm meter part # MA-DM1 and unhook the wires. Then set your meter scale on R x 1 and then put the leads on each sensor bar terminal. If good then you will ohm approx. .01-0 ohms. The same as if the 2-leads were tested together to make sure the ohm meter batty. is good. You want a complete path (no opens) on these two terminals. Now check from the microprocessor control part # 33003028 J-2 connector pins 3 and 4 where the sensor bar blue leads connect. UN hook them there and also ohm the 2-wires with the bar connected. The resistance from the total wire lengths connected should raise just slightly higher to approx. .5 ohms. If not find which lead has the possible open or short. This is mainly not the case in my opinion but it can happen. If all this is correct then you need to change the main control board. Thank You.

Read More...

1 Answer

Hello Barb. It sounds like the venting system is clogged or kinked. You will need to check the vent and clean it out. Be sure and clean the vent pipe and the dryer air duct assembly. If the air flow is not good, the unit will retain moist air causing the clothes not to dry. Try running the unit with the vent unhooked from the back of the dryer and see if the dryer works properly. Hope this helps.

Read More...

1 Answer

Hello Keith. On the back of the sensor bar 33001809 there are two terminals. You will attach the wire to the spade terminal that does not have a wire on it. Hope this helps.

Read More...

1 Answer

Hi Shondon. This means your dryer vent system is very clogged and probably getting ready to have a thermal fuse open. Please check that your vent hose is not clogged or kinked allowing the moist heat to back up into your cabinet. Make sure your outside vent hood/cap assembly is opening and closing properly. You should do this regularly 5 or 6x through out the year. Make sure your dryer vent length does not have any sags and normally is placed as so the moisture will normally drain outside. Hope this helps. Thank you.

Read More...

1 Answer

Hello David! It seems that the secondary coil has failed on your unit. It is suggested to replace both coils at the same time. Your coil kit is part number 279834. Thanks!

Read More...

1 Answer

Hello Joe. There should be two blue wires and a ground wire. The sensor bar is not used in the timed dry cycle. Hope this helps.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google