Customer Questions and Answers for Washer Snubber Ring by Whirlpool

Best Seller
Manufacturer Part
4.89 (64)
By: Whirlpool
Part Number: OEM18017367
Manufacturer Part Number: WP21002026

Snubber ring cushions the tub base during spin cycles. Replace if cracked, worn, or producing plastic shavings to restore smooth, quiet operation.

More
$10.71

IN STOCK
Ships Tomorrow Guaranteed
Add to Cart

Questions & Answers

For Whirlpool Washer Snubber Ring (Part Number: OEM18017367)

1 Answer

Hello Bill,

No you would not grease the snubber. You would want to clean the base with rubbing alcohol to make sure that it is clean.

Read More...

1 Answer

Hello Scott. Yes, based on the information you provided, it sounds like the snubber WP21002026 is bad and will need to be replaced on the unit.

Read More...

1 Answer

Hello Lency,

There a very few things that can cause the unit to shake violently. I'll mention them all. First and foremost, the leveling legs have to all four not only contact the floor, but also share the load. This is important because the inner tub is mounted on springs. This allows the springs to absorb the vibration of an out of balance load. If the body can move because it isn't setting level (evenly), it will hop, skip, and jump across the floor.

The second think I need to cover is the items that comprise the load. If there is one item that is more moisture absorbent, this item will weigh more and will throw the unit out of balance.

Now we are getting to the part that can be caused by the machine by itself. The balance ring is located around the top edge of the inner tub. If it is no longer attached to the inner tub or is damaged, it will cause the unit to shake violently. Also if the inner tub is loose, (it is attached to the upper transmission shaft with a spanner nut), this can cause the issue.

There are three suspension springs that could be damaged that should be inspected. I doubt that the snubber pads are involved as this would cause a distinctive noise. This will give you some things to check and hopefully will lead you to the issue. I tried to send you some literature that included some illustrated instructions, but your e-mail refused delivery.

Read More...

1 Answer

Hello Darlene. You need to check the dampers and see if they are bad. If so, you will need to order and replace the damper kit 203956.

Read More...

1 Answer

Hello Don,

I usually unplug the unit and tilt it back to access the pulleys. With the lid open and someone watching the agitator, turn the center pulley by hand. In one direction it will release the brake and the inner tub will spin. The other direction should turn the agitator only. If the agitator still doesn't move, the transmission will require replacement. If it does, you need to check that the motor is spinning when the unit goes into the wash mode.

Read More...
Alan S for Model Number Maytag Performa snubber ring.

I have a 6-7 year old performa that I purchased from Lowe's and it is the 3rd I've owned in my lifetime. From 2-previous generations of Maytag owners and one beneath me. From what I've read, I purchased a new nightmare back then. It does' the "snubber ring dance" that I haven't seen since I Love Lucy in the 60's! Health issues & finances force attempted repairs at home (having mechanical background) but I have lost the booklet on it and can't find the model number. A stupid and probably answered question; do all Maytag Performa's take the same snubber ring? Thanks, Alan

1 Answer

Hello Dennis. It sounds like you may have done something wrong with the thrust bearing 12002213. If it is installed properly, it releases the brake during the spin cycle. If it is not working, but is installed properly, you will need to replace the kit. Make sure the screws for the brake stator are good and tight and the snubber is installed between the stator and the rotor of the brake assembly.

Read More...

1 Answer

Hello Steve,

I certainly hope you didn't lubricate the snubber ring. This has to be put in dry and when replacing it, you should clean the area of contact with rubbing alcohol to prevent too much slipping around. If this was all done properly, you should check the ratcheting device that the rear legs are mounted to to ensure it is free. When you tilt the weight up off of the rear legs, you should hear it "click" as it's coming up off of the floor. This centers the ratcheting device so the unit can sit solid with no rocking of the base during spin. You should also check the locking nuts on the front legs. They should be tightened against the main base so the legs cannot re-adjust during operation. When the unit is properly leveled, the unit will not rock because the legs are sharing the weight of the machine equally. (Bubble leveling is not what this is referring to).

The only other thing I can think of is the main base. Some of these were released form the factory with a main base that was constructed out of too thin a gauge of metal. These are noticeable by excessive flexing of the main base during spin. They also will develop a hairline crack from the flexing of the metal. You have to look closely between the motor and snubber dome to detect the crack if present. It is also possible for the transmission shaft to be bent, but not terribly likely. To tell if this is the case, remove the inner tub and run the unit in spin. Looking straight down at the transmission shaft during spin will enable you to detect this as it will spin as a small circle instead of just spinning in the center.

Read More...

1 Answer

Hi Bruce. Remove the front panel. Look at the top of the base at the center area. Under the lower tub support there is a separate white snubber ring part # WP21002026 that may have worn the lower tabs off it and allow the plastic shavings to become too great. Move the tub from the front to the back. Do you see any fresh bas metal as it has worn past the base coating ? If so this snubber will need replaced. Lift the top and unsnap the top tub outer cover. Inside it is a balance ring that has concrete balance that may be broken and needing replaced part # 21001531. Are the leg adjuster nuts tight up against the cabinet base after the unit is properly leveled to hold it tight? Are the leg pads worn out causing them not to grip the floor properly ? Legs part # WP25001119. Thank You.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google