1 Answer

Hello BC. Try turning the cold control WP2198202 and see if the unit starts to cool again. If so, then the cold control is bad and will need to be replaced. If not, you will need to check and make sure the compressor is running. If it is just clicking, and the relay overload is new, then it sounds like the compressor is bad and will need to be replaced. Hope this helps.

Read More...

1 Answer

J-Hawk, No, your fridge may not start to cool, right away. Depending on which position the timer is in. at the start of the defrost cycle, It could take as much as 30 to 40 minutes before the compressor starts and runs. If the timer is in a cooling mode, then the compressor should start and run in as much as 5 to 7 minutes. You can manually advance the timer shaft into a cycle, but be careful, you don't want to damage the new part contacts. Thanks and Good Luck

Read More...

1 Answer

Hello Anthony. It depends on the setting of the timer W10822278, and what terminals you are testing. We will need to know this information. Thank you.

Read More...
Max H. for Model Number GT22DMXGW01 12 year old Whirlpool R/F

I am away from home for extended periods of time and due to age of fridge,I decided on some PMs. I changed out the defrost timer AP3110896 and connected the black wire to terminal #1. I have also changed out the overload/relay combination AP3108669.On the relay, the white wire was replaced on the side with the two lugs(run leg?) and the red wire was replaced to the single lug on the overload. I also noticed that this model compressor had no run capacitor. I observed that for the past three days, that the condensor fan is continually cycling at a 5 min. on/8 min. off period and that there is not much pitch on the fan blades. Both the freezer and fridge seem to be cooling adequately and the icemaker seems to be working properly. The start and run legs of the compressor ohmed out at 6.4 ohms each and the condensor fan at 190 ohms. My questions are: 1-Is this cycling normal or is something in failure mode? 2-Would it be to my advantage to install a run capacitor across the compressor start relay? 3-Are any other parts near the end of their useful life and need replacing? Many thanks for any and all suggestions. Max

1 Answer

Hi Max. A compressor relay capacitor will allow the compressor to run in a more efficient manner and last longer. This is my opinion professionally speaking. Some models do not have them and it seems it has been in the last 5-7 yrs they have been more and more depending on the manufacture. They are elect. connected to the start and run terminals of the run relay. As far as the defrost timer is concerned, the #3 terminal has the white wire. The #4 terminal has the red wire. The # 1 has the orange wire (as the timer motor lead wire is normally connected there also). The # 2 terminal has a pink double wire going to it. If the unit is cooling fine, then all is well. The condenser fan and the evaporator runs along with the compressor running. The cold control regulates the run as long as the set point is not satisfied. As the defrost timer comes out of defrost , it may need to wait approx. 6 minutes for the defrost thermostat to reset (close) dwell time and then the compressor will kick in. Then it will allow the compressor to run and allow the cold control to be satisfied. Compressor capacitor will be part # WP4387764. A capacitor is designed to store voltage and discharge it at a predetermined rate. This being said it allows the lead and lag time of the compressor to become more closely in "electrical sine wave" with each other and be more efficient. Thank You .

Read More...

1 Answer

Chris, It doesn't matter, The defrost heater assembly is not a polarity sensitive circuit. As long as the brown wire from the d/f thermostat attaches to one wire of the heater and the white wire going into the harness is attached to the wire of the heater element, you'll be fine.Thanks and Good Luck

Read More...

1 Answer

Hello Rafa. Based on the model number, here is the procedure for the timer W10822278. For cumulative run timer
push slotted loose timer
motor lead over & all the
way down terminal
number 2 with wire
toward timer motor. Hope this helps.

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google