Rafael for Model Number RS25AGXNQ02

Recently, my refer has been running and it is louder than usual for I have noticed. The refer side did not feel as if was cooling properly .There was barely any airflow coming through the vent and then finally none(evap motor not runing I figured). I noticed that the freezer back panel was frosted over. Once I took the panel off plugged back in and evap motor was working and airflow was resuming. Defrosted the coils whcih were frosted over manually with hair dryer .Figured that was it problem solved Feezer and refer working fine.Last few days I have noticed that freezer back panel is a bit frosty . To me I haven't noticed if the fridge has turned off to defrost mode. It just sounds on all the time and a bit louder than usual. My wife says I'm losing it ,but a feeling tells me there is something not right. Please help with any suggestions to test out

1 Answer

Hi Rafael. The process you are going through is a normal defrost issue. Normally the failure of the defrost thermostat part # WPW10225581, not closing as the defrost timer sends the 120 vac part # W10822278 to it . In The fresh food area at the top rt. side there is this defrost timer. With a large blade screwdriver you can advance this dial to the first heavy click to start the defrost cycle. At this point, did the timer send the 120 vac to the evaporator mounted defrost thermostat ? Was the graduations of the turning detents seem difficult to do ? It should turn positively easy. If not then this is a telltale sign of a defective part. If it does not send the voltage to the thermostat, it is bad. The thermostat has to close at 14° or below. If you test it with a ohm meter and a temperature gauge, then you can tell. If it does not close to send the voltage to the heater then defrost will not occur. Then you need to disconnect the evaporator heater and test for resistance between 8-11 ohms (approx.). If it is -open- it will not conduct heat. It is part # WP2323198. You can purchase a volt/ohm meter at the local hardware very cheap. Thank You.

Read More...

1 Answer

Hi Chris. No, your model needs the wire connected to the # 1 terminal so it is a continuous run application as the instructions imply. They are confusing. Most of the time 98% of units hook up to the black at the # 1 terminal. Great question ! Thank You.

Read More...

1 Answer

Hello RR. The defrost timer W10822278 can be located behind the toe panel, in the compressor compartment, and in the control section. Without a model number, there is no way to tell you for sure. When you locate the timer, you will see the numbers by the terminals. As long as you find a timer with the same number pattern, and the same amount of cycle time, it will work in the unit. Hope this helps.

Read More...
Craigo for Model Number sears coldspot 106.7635240

Installing d/frost timer kit AP3110896. Slightly confused by continuous vs. cumulative, old timer harness connecting to pins were two white on 3, red on 4, black on 1 and red on 2. I hooked the black lead coming from timer to pin 1. Correct? also when I plugged it in the compressor didn't kick on, so I had to rotate the timer til it clicked then it kicked on when I plugged it in. I cut and taped off the green wire that hooked on to the defective timer. Should I be good to go?

1 Answer

Hi Craig. Yes the difference between all the explanations can be confusing. The black motor wire will generally always go on the # 1 terminal. You should be fine. This will give the defrost timer motor the 120 vac needed for proper operation by the timer. There are a bunch of 6-1/2 hrs of timer graduations as you rotate the timer knob. There are precise and simply tiny clicks. The defrost cycle will start when you advance the detentions at the first "Heavy Click". The defrost cycle will normally stay active for approx. 25 minutes and then at the "2 Heavy click" it stops the defrost and starts the compressor in the normal run time. 24 / 7 days a week. Thank You.

Read More...

1 Answer

Andrew, It sounds like you have wired your new timer as a cumulative version 2 / procedure 3 according to the instruction sheet. it actually sounds like the timer is working proper. But if the freezer is getting too warm in the defrost cycle, you need to consider the defrost thermostat WPW10225581, Check and make sure the thermostat has not gotten disloged from the panel it's mounted on and then replace it, it would most likely be hanging up and causing an over heat situation. Good Luck and Thanks

Read More...

1 Answer

wBingie, Yes, correct, if you have a version 2 accumulative compressor defrost timer, you connect the loose black wire on the new timer to terminal #1, along with the black wire in the timer wire harness. Very good job. Thanks and Good Luck

Read More...

Have questions? Ask our pros!

Contact us in a way that is convenient for you

Call us 1-877-477-7278
Need Help? Chat with a Pro
Or ask a question by filling in the form

Share your thoughts with other customers

Ask a Question
  • 5,000+ Repair Videos 5,000+ Repair Videos
  • Same-Day Shipping Same-Day Shipping
  • 365 Day Return Policy! 365 Day Return Policy!
  • Repair ForumFree Tech Support!
  • Top Quality Store on Google