Brime December 05, 2011 i have up rigth freezer kenmore madel#106-8253580, i installed defrost timer part#482493,with terminal#1 black two wires,terminal#2 pink 1 wire,terminal#3 red 1 wire,terminal#4 orange 2 wires,i try the black terminal from the timer in terminal 1 and 2 but i have no defrost,what do you think is the problem,the unit has a new defrost limit, and also i check the defrost heater ok,thanks.
1 Answer Brime, based on your wiring information in your post, you have "version 2" and you followed Procedure 2 on page three of the instuction manual, is that correct ? You do understand that the defrost cycle will not activate until the compressor has a total of 8 hours of run time( this could take a couple of days to accumulate the time). Here's a quick test and check. With the freezer plugged in and cooling, slowly advance the defrost timer with a screwdriver, until the timer "clicks" and the compressor turns off, this will be the defrost cycle, in a few minutes you should hear the water sizzle when it drips off the evaporator and hits the heater. In 25 to 30 minutes you should hear another click, and the compressor should start to run in a few minutes if not right away. Thanks and Good Luck Read More...
Bill November 20, 2011 for Model Number et8ftkxkt01 I bought a defrost time part # 482493 for a whirlpool refrigerator model # ET8FKTXKT01. The timer has a black wire lead, what teriminal number do I put it on.
1 Answer Hello Bill. The black wire goes onto terminal number 1 on the timer W10822278. Hope this helps. Read More...
Bob October 27, 2011 for Model Number Kenmore refrigerator 106.9557621 Trying to install defrost timer 482493 on Kenmore 106.9557621 refrigerator but don't know which terminal to use for black wire. Thanks for your help
1 Answer Hello Bob. Based on the information you provided, the black wire goes onto the number 2 post of the timer. This is the cumulative run process. Hope this helps. Read More...
Tim October 18, 2011 for Model Number ED22RQXXWOO How do I remove the control box? I have removed the 2 hex screws but the front will not come loose.
1 Answer Hello Tim. The front panel of the control box unsnaps off the control box, and there are screws behind the panel that will need to be removed. Then the control box will drop down so you can access and replace the defrost timer W10822278. Hope this helps. Read More...
Mukesh P. September 08, 2011 for Model Number KSRB25FHSS02 Kitchen aid I ordered Defrost Timer Kit Order Number: 2083948. Part Number AP3110896 (482493). What type of run application go with this model from the instruction? 1) Continuous Run application 2)Version 1 - Cumulative Compressor Run application or 3) Version 2 - Cumulative Compressor Run application? Thank you, Mukesh
1 Answer Hi Mukesh.Refer to procedure # 3 of the instruction sheet "Timer motor lead For cumulative run timer push slotted loose timer motor lead over & all the way down terminal number 1 with wire toward timer motor. NOTE: When wired correctly to a refrigerator’s accumulated run clock, replacement timer will provide defrost every 8 hours of compressor run time after the bimetal closes. Good Luck and ThanksRead more: http://www.appliancepartspros.com/Appliance-Parts/whirlpool-refrigerator-defrost-timer-kit-item-number-ap3110896.aspx#ixzz1Xkz4df97'>http://www.appliancepartspros.com/Appliance-Parts/whirlpool-refrigerator-defrost-timer-kit-item-number-ap3110896.aspx#ixzz1Xkz4df97 http://www.appliancepartspros.com Thank you. Read More...
J.D. September 03, 2011 for Model Number ed25texhw00 I replaced defrost timer part.#2176648 (pk-2,or-1,r-4,w-3) with a part.#483212 but the package read part#482493. Where do I connect the black wire? Do I have the correct part.
1 Answer J.D. Refer to procedure # 3 of the instruction sheet "Timer motor lead For cumulative run timer push slotted loose timer motor lead over & all the way down terminal number 1 with wire toward timer motor. NOTE: When wired correctly to a refrigerator’s accumulated run clock, replacement timer will provide defrost every 8 hours of compressor run time after the bimetal closes. Good Luck and Thanks Read More...
Bo September 03, 2011 for Model Number TBX21JI The refrigerator works until it gets to the defrost cycle. It then trips the GFI. Could this be a bad defrost timer, or is something else tripping the GFI?
1 Answer Bo, Yes, it could be a bad defrost timer, but probably not. its more likely to have a defrost heater issue WR51X465, or a shoted,pinched wire. or loose connection. Also check to make sure you did not add another appliance or product to the circuit, causing a draw on the system, and causing the GFI to open. Thanks and Good Luck Read More...
Wade A. September 02, 2011 for Model Number e71chmxkb03 Where is defrost timer located, so I can replace?
1 Answer Hello Wade. The defrost timer W10822278 is located in the control panel inside the refrigerator. Here is a link to the parts diagram page to help you locate it. Hope this helps. http://www.appliancepartspros.com/partsearch/model.aspx?model_id=5511190&diagram_id=28109874 Read More...
Robert A. August 08, 2011 for Model Number ED2FHEXNQ (Whirlpool Side by Side) Ice forms on the inside back pannel of the freezer and the fan blade hits against the ice formation. This is visable by removing the evaporator cover. I have removed the ice build-up only to have it repeat in a couple of days or so.
1 Answer Hello Robert. You will need to test the defrost heater WP2323197 and the defrost thermostat WPW10225581. They should read closed for continuity when cold. If they are good, you will need to replace the defrost board WPW10366605. You can test this with a multi-meter TJMA-DMT3. Here is a link on how to use a multi-meter. Hope this helps. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html Read More...
Eric August 03, 2011 for Model Number RS22AGXTQ00 The fridge side of my side by side every so ofter warms up and then will cool back down after acouple hours to a day. I was told by my father-in-law that is was the evap. fan motor, I took the panel off and the fan is going fine, it is blowing out warmer air though. Also the evaporator coils are frosted over and some are bent. Is it the defrost timer, heater or thermostat? Thanks
1 Answer Hi Eric. The back freezer wall frosting up is conducive to a defrost failure. The defrost heater is part # WP2323197. The defrost thermostat is part # WP2323197. Both of these parts are clipped onto the evaporator. Thank you. Read More...