Gregory December 03, 2018 for Model Number MEDB800VQ0 The dryer will run for about 5 minutes and the house circuit breaker will cut out. I can reset the breaker and it'll run again for 5 minutes and then kick off again.
1 Answer Gregory,I would start my troubleshooting at the terminal block of my dryer. Check for loose connections or damaged wires from loose connections. Test your voltage after you start the dryer and make sure you keep the 240 vac. Test your cord for continuity and make sure line and neutral are not touching in the cord. Read More...
1 Answer Hello Kevin, We will need to ask you to please provide a model number so we can pull the wiring diagram. This will enable us to provide you with an accurate answer to your question. Thank you for your patience and understanding in this matter. Read More...
1 Answer Hello John. Unplug dryer or disconnect power. Remove three screws from the rear of the console assembly. Pull console towards front of dryer to hinge open and/or remove console. Remove the wire connections to the machine control assembly. Remove the one screw holding the machine control assembly to the metal bracket. Push in on the tab located on the back of the machine control to slide it off the bracket. Reverse the procedure and test the dryer for operation. Read More...
Heidi October 23, 2016 for Model Number MEDB800VQ0 I have had the Maytag Bravos Quiet Series 400 Steam Dryer for a few years. My problem is that it suddenly quit heating up. The dryer starts and sounds normal when tumbling. However, there is no heat being produced. Any idea what part(s) we should be looking at replacing (thermostat?, heating element?). Please let us know as soon as possible. Thanks.
1 Answer Hello Heidi. Check and make sure you have 240 volts coming to the dryer. Check and make sure the unit is not set to Air Fluff. Also check the heater and thermostats and see if they are good. You can test these with a multi-meter MA-DM1. They should read closed for continuity. Here is a link on how to use a multi-meter. http://forum.appliancepartspros.com/oven-repair-including-ranges-cooktops/4810-how-check-continuity-ohmmeter.html Read More...
1 Answer Hello Kerry. Here is a link to our warranty policy. http://www.appliancepartspros.com/customerservice/returns.aspx Read More...
Charles June 20, 2015 for Model Number MEDB850WQ0 The dryer is powered up, and we can select any option. However, when we press start, there is a click but the dryer will not start. I have killed the power and restarted but same result.
1 Answer Hello Charles. You need to check and see if the thermal fuse WP3390719 is bad and will need to be replaced on the unit. Read More...
Dan April 10, 2015 for Model Number MEDB800VQ0 I'm getting an error code "F01", I'm reading that the control board needs to be replaced but not sure if that is W10336131 or W10111620
1 Answer Dan, You're on track," F0-1 Primary Control Failure > F:01 flashes when there is a primary control failure. Replace the machine control electronics. You will need to replace the Machine control board WPW10111620 / W10111620. " Unplug dryer or disconnect power. Remove three screws from the rear of the console assembly. Pull console towards front of dryer to hinge open and/or remove console. Remove the wire connections to the machine control assembly. Remove the one screw holding the machine control assembly to the metal bracket. Push in on the tab located on the back of the machine control to slide it off the bracket. Reverse the procedure and test the dryer for operation. Read More...
Eric April 06, 2015 My bravos dryer will not start. The display lights all work, the sensor light is lit up, but it will not start. What could the problem be?
1 Answer Hello Eric. You will need to test the thermal fuse, door switch, and broken belt. Either could cause the issue your having. Read More...
Brenda K September 07, 2014 for Model Number MEDB400VQ Power went out. dryer was beeping 3 times. turned off.Next day dryer was not working.Display did not have anything showing until we left door open and tried to start. showed " lid". the lights for start and wash selection are flashing. If we keep pushing start sometimes the display will show "1 hr" will increase if we push the + button. We checked breaker and fuse. unplugged for 2 min.and checked the lint basket and vent. Any idea what is wrong?
1 Answer Brenda, With the issue that you are having, this sounds like it would be caused by a faulty main control board that would need to be replaced. Read More...
Angela August 12, 2014 for Model Number MEDB850WQ0 My Maytag Bravos MCT dryer will light up on the right side but not on the left side where time is displayed. And it will not start. I ordered and replaced the thermo fuse and the thermistor but it will still not start or light the left side. What do I do next to fix this dryer?
1 Answer Angela, The most likely cause for the display to work on the right but not the left would be a faulty used interface board WPW10336131.. Read More...