Marisa August 17, 2023 for Model Number 5303918344 My ice maker won’t stop making ice and it overflows. I can turn it off and it stops. Is there something wrong with the arm that senses there is enough ice? Would I need to get the entire ice maker kit?
1 Answer Marissa, This would be an issue with the icemaker and it would need to be replaced. Read More...
Rob November 14, 2022 for Model Number FGHS2655PF4 Replaced water filter and water inlet valve. Still not making ice. I poured water into the ice maker to try to see if that worked. It dropped ice from the water poured. Checked water line for kinks. There were none. Water does dispense from the door with no problem. Any ideas? Also, what should the freezer be set at? My numbers are 1 thru 9.
1 Answer Rob, the freezer should be set to where it is at 0°F when measured by a thermometer. As the icemaker was able to harvest when water was set into it, was there a humming that came from the valve after it dumped the ice? If not, the failure would be in the ice maker 241798231. If there was humming, the fill tube would need to be inspected for ice clogging the line and clearing as necessary. Read More...
Jesus May 12, 2022 for Model Number E23CS75DSS7 I need to replace the unit, as it stopped working My unit has a vertical switch, and this one is horizontal I don't think the cover will fit Is there another option?
1 Answer Jesus, the manufacturer does not list an alternative from the recommended ice maker 5303918344. The ice maker comes with the front cover already installed. Read More...
Alan November 12, 2021 for Model Number frss2323as0 How do you adjust cube size in ice maker part 5304525923? Mine are way too small. It has an on/off button on the front with a second recessed button to the right of it.
1 Answer Alan, Thanks for the question!!! This icemaker has no adjustment for cube size. Check the water flow through the water valve as that could be the more likely issue. Read More...
Jack May 24, 2021 for Model Number Frigidaire FPHC2398LF1 Do I need to turn off the water supply in order to replace the current ice maker??
1 Answer Jack, the water supply would not need to be turned off. However, it would be recommended that the power supply to the refrigerator is unplugged before replacing the ice maker as this will prevent the main control from possibly becoming damaged during the repair. Read More...
Jack Walsh May 23, 2021 for Model Number FFHS2622MS3 Icemaker stopped making ice for a long time. Decided we needed to have it work. Water dispenser on door works fine. When I pushed and held the on/off switch on the ice maker for 15 seconds, it rotated the ejector, and pushed out 3 pieces of ice. I then closed the door. When I opened it a few minutes later, water was running out of the ice maker. When I turned the switch to off, the water stopped. The door water still works. If I turn the ice maker switch to on, the water runs out again. What is going on? What controls the flow of water to the ice maker tray? What do I need to replace??? HELP!!!!
1 Answer Jack, Because the water valve turns off when the icemaker is shut off then this would be an issue with the icemaker that would need to be replaced. Read More...
Amy January 04, 2021 for Model Number IcemAker Is it possible to make ice less dense and more easily chewable?
1 Answer Amy, if the model number of your appliance could be provided in a new question, this will allow for the most accurate information to be presented. Read More...
David December 10, 2020 for Model Number PHSC239DSB0 When I use the door for water, the ice maker tube begins to flow as well. This has caused the entire ice maker assembly to freeze up and water pooled all over the freezer, turning into large puddles of ice. Is this the water valve?
1 Answer Hello David, You will need to order and install a diode kit 5303918287 to prevent this issue. Shorted diode: When you activate the dispenser and water comes out both the dispenser and ice maker fill tube, the harness needs to be replaced. 1. Disconnect the power cord 2. Remove connector from single coil valve and remove the dark blue and yellow wires from the Molex connector. 3. Cut the two dark blue wires about 1" from the diode. (The diodes are inside the black heat shrink that the blue wire with yellow tracer goes into one end and the 2 blue and 2 yellow wires come out the other end) 4. Cut the yellow wire about 1" from diodes 5. Remove old diode subassembly. 6. The 2 blue wires cut in step 3 need to attaché to the brown wire in the new diode harness with the connector provided. Slide the heat shrink over the wire first, install the connector and slide the heat shrink over the connector and heat to seal the connector. 7. The 2 yellow wires cut in step 3 need to be attached to the yellow wire in the new diode harness with the connector provided. Slide the heat shrink over the wire first, install the connector and slide the heat shrink over the connector and heat to seal the connector. Read More...
Fernando October 19, 2020 for Model Number icemaker for electrolux refrigerator model plhs267zdb1 The rocker switch wont stay on (I). But when I press off (0), it stays engaged. What is the cause of this? The video shows exactly the same icemaker I have. I would really appreciate your response. Thanks again.
1 Answer Fernando, the rocker switch of the ice maker will sit in the middle position when the ice maker is turned on. Pressing and holding it at the on position causes a forced harvest. The ice maker rocker switch is operating properly. Read More...
Jerry G. June 24, 2020 for Model Number FRS6B7EESB8 When dispensing water, water is also dispensing to the ice maker and causing an overflow. I have the correct water pressure. I don't have the capability to check voltage at the solenoid. Need help. Thanks
1 Answer Hello Jerry, You will need to order and install a diode kit 5303918287 to correct this issue. This kit may be used for the replacement of diodes in ice and water-side by sides with a water filter. The diodes are part of the main harness. Thre is a black insulator that protects the diodes. The diodes are located on the wire that goes to the inlet valve (#1 single coil valve), Approximately 4" away from the valve. Testing Shorted diode: When you activate the dispenser and water comes out both the dispenser and ice maker fill tube, the harness needs replaced. Open Diode: If the icemaker diode fails open, the single water valve will not energize when the icemkaer is activated. If the dispenser diode fails open, the single valve will not energize when the dispenser is activated. Equipment needed: Voltmeter. 1. Activate dispenser, then check to see if there is voltage to the dispenser valve (Yellow Coil of the dual valve should have close to line voltage) and check the inlet valve (single valve #1 can be tan or green, should have 54 to 78 VAC) If no voltage to both the inlet valve (Single valve) and the dispenser valve (Yellow Coil) then : A. Check the freezer door wiring connector. B. Check the dispenser connections. If there is voltage to the dispenser valve (Yellow Coil) and not to the inlet valve (Single Valve) replace the diode harness. 2. Activate Ice maker (Check during icemaker fill, which is about 7.5 seconds), then check to see if there is voltage to Icemaker valve (Green Coil of the dual valve should have 95 to 105 vac) and check the inlet valve (Single valve #1 can be tan or green should have 42 to 58 VAC) If there is voltage to the icemaker valve (Green Coil) and not to inlet valve (Single Valve) Replace the diode harness. Replacement of Diode on Refrigerators with the single-coil valve by the condenser fan and two valves by the compressor: 1. Disconnect the power cord. 2. Remove the connector from the single-coil valve and remove the dark blue and yellow wires from the Molex connector. 3. Cut the two dark blue wires about 1" from the diode. (The diodes are inside the black heat shrink that the blue wire with yellow tracer goes into one end and the 2 blue and 2 yellow wires come out the other end). 4. Cut the yellow wire about 1" from diodes. 5. Remove old diode subassembly. 6. The 2 blue wires cut in step 3 need to be attached to the brown wire in the new diode harness with the connector provided. Slide the heat shrink over the wire first, install the connector and slide the heat shrink over connector and heat to seal the connector. 7. The 2 yellow wires cut in step 3 need to be attached to the yellow wire in the new diode harness with the connector provided. Slide the heat shrink over the wire first, install the connector and slide the heat shrink over connector and heat to seal the connector. Read More...