Mitch May 02, 2020 for Model Number FGHC2331PFAA Refrigerator too cold. Replaced thermistor and damper control, neither fixed problem. Thinking control board. We had power outage that caused lights to go on and off several times, might have damaged the control?
1 Answer Mitch, This could be a control board issue if you have checked or replaced all four thermistors. There are two thermistors in the FF section, one in the freezer section and one for the ambient temp. See the wiring diagram that came with the refrigerator. Read More...
1 Answer Hello Robert, you'll want to test on the user interface board to verify the control board is sending the proper voltage. You should see 12vdc on J7-1 to J7-3, if present the control board is doing it's job and the user interface has failed. Good Luck! Read More...
Alex September 05, 2019 for Model Number FGHC2331PFCA is the display on the replacement board green or blue, my customer wants blue to match wine cooler?
1 Answer Alex, To the best of our knowledge, the display is usually green in color. The manufacturer doesn't stipulate a specific display color or parts number change. We don't have access to the part and can't check or verify the display color. The 5304527931 / 242058232 User Interface, assembly, grey, complete, is the correct part for the model number you supplied. Thanks, Read More...
Leninston August 26, 2019 for Model Number frigidaire fghs2655pf5a sections of the LED number display are missing and refrigerator section is warm while freezer is too cold. Is the problem related and is the control board incorporated in the interface or is it separate?
1 Answer Leninston, The user interface and main control are separate. You will need to replace the user interface to repair the missing segments. 5304527932. We are sending you a service sheet to test components from the user interface after it is repaired. You will need to activate the diagnostic mode and inspect test 22 which is the damper and the thermisters which are tests 29.30 Read More...
Gary May 29, 2019 for Model Number Frigidaire Gallery All the LED lights inside my Frigidaire Gallery stopped working at the same time. Does anybody have a suggestion of the cause?
1 Answer Hello Gary, While this issue is normally caused by a wiring issue or a main control, we would still need to ask you to please post a new question including the model number from your units' I.D. tag so we can provide a proper diagnosis and recommend parts that can be guaranteed to work properly on your unit. Thank you for your patience and understanding in this matter. Read More...
Robert May 26, 2019 for Model Number FGHS2631PF4A One of the LED lights went out on the user Interface, can I replace the light individually, or do I have to buy a new user interface entirely?
1 Answer Robert, to repair a failed LED light on the user interface display 5304527931 the entire interface would need to be changed out. Read More...
James May 13, 2019 for Model Number FGHC2331PFAA How does the light board #AP5952241 come off to replace or put on the new interface ?
1 Answer James, The part number you listed is held in by clips. Remove the cover and the part snaps out. If you are asking about the interface on the door there are two screws underneath the interface by the water dispenser that you take out and remove a cover then the screws for the interface are exposed. Read More...
James May 11, 2019 for Model Number FGHC2331PFAA To replace the interface. Do the plugin wires just pull out ? They seem to be very secure. Will they come out with a little wiggling?
1 Answer Hello James, yes the connectors will come out by pulling them out. You'll want to grip the connector and try slowing wiggling out rather than tugging on the wires. Make sure these connectors do not have a locking tab before trying to pull them out. Hope this helps! Read More...
Ken April 07, 2019 for Model Number FGHC2331PF0 User Interface beeps frequently without touching it. Range of time between beep events varies between just a few seconds to 5 minutes. When it beeps the white menu listing shows for about 10 seconds and then reverts back to normal display. Everything seems to be working fine otherwise. This has been going on for about 2 weeks following a 2 hour power outage. I think the episodes are getting more frequent and more random. Attempted remedy: Tried cutting power at the fuse box for 10 minutes. No change. Is there anything I can do or do I need a part? Thanks
1 Answer Ken, the beeping from the user interface and menu showing up is going to indicate that the user interface board [242058253] is sensing selections being made. Most likely user interface has a stuck selector causing this issue. Read More...
Neil December 30, 2018 for Model Number FGHS2655PF5A My interface display is missing a couple sections of the readouts. Also, at the same time this happened, freezer started to frost and fridge is warm. Condenser coil isn't frosted and fan is running. Could the issue just be the interface? Or is itore likely multiple issues?
1 Answer Neil, For this issue of the display missing sections then it would need a new user interface. For the issue of the freezer frosting then this would be a defrost issue and would need to test the defrost heater and defrost thermostat for continuity and if this checks ok then the issue will be the control board. Read More...